EEWORLDEEWORLDEEWORLD

Part Number

Search

3120-F354-P7T1-W02A-0.2A

Description
1 POLE(S), 0.2A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
CategoryCircuit protection    Circuit protection   
File Size441KB,5 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

3120-F354-P7T1-W02A-0.2A Overview

1 POLE(S), 0.2A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F354-P7T1-W02A-0.2A Parametric

Parameter NameAttribute value
Objectid1145922004
Reach Compliance Codecompliant
Actuator typeROCKER
body width21 mm
body height33 mm
Body length or diameter56 mm
circuit functionMANUAL ON/OFF
Circuit protection typeTHERMAL CIRCUIT BREAKER
Installation featuresPANEL MOUNT
Number of poles1
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size56mm x 21mm x 33mm
Rated breaking capacity2 A
Rated current0.2 A
Rated voltage (AC)250 V
Rated voltage (DC)50 V
GuidelineCCC; CSA; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
3120-F3...F5
Typical applications
Technical data
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
Standard current ratings and typical internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2-pole)
Insulation resistance
Interrupting capacity I
cn
3120-F7
2
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings
0.1...20 A
(up to 30 A to special order, single pole only)
Typical life
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
0.1...16 A
0.1...16 A
17...20 A
DC 50 V:
0.1...16 A
17...20 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
1-pole
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, resistive
30,000 operations at 1 x I
N
, inductive
2-pole
10,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Illumination voltage/power consumption
operating voltage
12 V DC
24 V DC
115 V AC
230 V AC
power consumption
Y+R
2 mA
2 mA
0.9 mA
0.9 mA
G
3.5 mA
3.5 mA
2.8 mA
2.8 mA
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A 10 x I
N
2.5...20 A 250 A 2-pole, or 150 A 1-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
1, 2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A
1000 A
Approvals
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
DC 50 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V; DC 50 V
Current ratings
0.1...20 A
0.1...20 A
2-pole
0.1...10 A
1-pole
0.1...20 A
0.1...20 A
Shock
Corrosion
Humidity
Mass
UL, CSA
CCC
operating area IP40
(IP54 with water splash protection)
terminal area IP00
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 33 g (double pole)
approx. 27 g (single pole)
Issue D
www.e-t-a.de
2
- 67
Design of vehicle-mounted turntable dynamic monitoring system based on DSP and AD1674 AID conversion chip
Turntables are optomechanical and electrical integrated equipment widely used in the fields of aviation, aerospace, weapons, navigation, etc. The vehicle-mounted turntable system has been widely used ...
Jacktang DSP and ARM Processors
Ask about OEMaddressTable
I would like to ask you for help: In order to upgrade the nor flash from 32M to 64M, I modified the flashWrite and flashErase functions in EBOOT and modified the OEMaddressTable. Nothing else was modi...
407406136 Embedded System
Is there any TX engaged in EMS development?
Are there any TX engaged in EMS development? I have been unable to find a more professional forum, so I have created a GROUP. If you are interested, please take a look. I hope we can discuss EMS or SN...
shhuikun Embedded System
The microcontroller is connected to a gprs module (with a sim card installed). If you want the mobile phone to send text messages to the module, how can you let the microcontroller know that a text message has arrived?
The microcontroller is connected to a gprs module (with a sim card installed). I want the mobile phone to send text messages to the module. How can I let the microcontroller know that a text message h...
liyanqing611 Embedded System
AXD Debugging Issues
[CLKDIV_VAL>1; means Fclk:Hclk is not 1:1. mrc p15,0,r0,c1,c0,0 orr r0,r0,#0xc0000000 mcr p15,0,r0,c1,c0,0 --->When single-stepping to MRC P15, RO, C1, C0, 0, an exception occurs and execution cannot ...
FionaLiu Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2320  2132  2908  1870  1454  47  43  59  38  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号