Part Number

Search

778266-01

Description
Controller Area Network (CAN) Interfaces
File Size516KB,6 Pages
ManufacturerNI
Websitehttps://www.ni.com
Download Datasheet View All

778266-01 Overview

Controller Area Network (CAN) Interfaces

Controller Area Network (CAN) Interfaces
NI CAN Series 2 Interfaces for PCI, PXI, and PCMCIA
• Hardware timing and synchronization
with NI data acquisition, vision,
and motion devices
• 100% bus load; for up to 1 Mb/s
• ISO 11898-compliant for standard
(11-bit) and extended (29-bit)
arbitration IDs
• Philips SJA1000 CAN controller
• Available in high-speed,
low-speed/fault-tolerant,
and single-wire versions
• Hardware timestamping
• Intel 80386EX microprocessor
for timed CAN frame transfer
• Optical isolation up to 500 V
• Import Vector database files
with NI-CAN
Operating Systems
• Windows 2000/NT/XP/Me/98
• LabVIEW Real-Time
Recommended Software
• LabVIEW
• LabWindows/CVI
Other Compatible Software
• C/C++
• Visual Basic 6
Application Software (included)
• Bus monitor utility
Driver Software (included)
• NI-CAN
Overview
CAN interfaces meet the physical and electrical requirements for in-
vehicle automotive networks based on CAN. All CAN interfaces
include NI-CAN device driver software, with which you can import
CAN channels from Vector database files or create them in an
easy-to-use utility and program using a high-level API. With a
National Instruments CAN interface and NI-CAN software, you can use
a desktop, industrial, or notebook PC running Windows for a variety
of CAN applications, including automotive testing and diagnostics,
prototype design, factory automation, and machine control.
cables to take advantage of synchronization. For PCI boards, you can
use a RTSI bus cable to share the signals. For PCMCIA-CAN, a
synchronization cable connects external timing and triggering signals
to the card to achieve synchronization between PCMCIA-CAN and
PCMCIA, USB, or PCI data acquisition hardware.
LabVIEW Real-Time Compatibility
PCI and PXI CAN hardware works with LabVIEW Real-Time running
on a PC or a PXI controller for deterministic control. You can download
your existing NI LabVIEW application to the target without specialized
real-time OS programming knowledge. The real-time performance and
synchronization mean you can use a standard PC or PXI chassis for
applications such as rapid control prototyping, hardware-in-the-loop
testing, and data logging.
CAN Bus and Analog Data Synchronization
Recent advances in automotive test applications demand tighter
integration of CAN and other measurement devices. In many
applications, you need to synchronize the physical parameters
measured in time to correlate the data. You can program this
synchronization in software, but OS latency sometimes introduces
unacceptable delays for certain automotive test applications.
National Instruments CAN, data acquisition, vision, and motion
boards for PCI are equipped to share timing and triggering signals.
In a system, a CAN board can share timing and triggering signals
with data acquisition, image acquisition, or motion control boards,
basing their actions on these signals. Determinism is maintained
between the trigger signal and the desired response because timing
and triggering signals are handled in hardware. The host PC software
interacts only to retrieve the data once it is acquired or to write
new data.
Synchronization is available for PXI, PCI, and PCMCIA-CAN
devices. For PXI modules, the timing signals are shared in the PXI
trigger bus on the backplane; therefore, you do not need additional
Common Hardware
All National Instruments Series 2 CAN devices use the Intel 80386EX
microprocessor to handle communications directly on the interface
device. The 80386EX provides a dedicated environment for reliable,
high-performance CAN communications protocol stack execution.
Because acquisition and transmission timing occur on the board,
CAN frames are not lost due to OS activity such as hard drive
access, mouse movements, or virus scans. The physical layer of all
National Instruments CAN devices fully conforms to the ISO 11898
physical layer specification for CAN and is optically isolated to 500 V.
You can interface to the CAN bus using a 9-pin male D-Sub (DB9)
connector. The Philips SJA1000 CAN controller implements typical
ISO 11898 CAN functionality and offers additional functionality to aid
in system development, such as listen-only mode, sleep/wakeup mode,
error counter access, and self-reception (echo) mode.
Kernel Configuration Instructions
-------------------------------------------------------------------------------------- [color=#ff0033][font=宋体]The most luxurious and applicable [/font][font=Arial]S3C2440[/font][font=宋体]development p...
qq17 Embedded System
【MicroPython】LAB01 - Flowing Light
[i=s]This post was last edited by slotg on 2016-5-4 15:59[/i]The Pyboard is equipped with 4 LEDs. You can directly use the pyb.LED(i).on() or pyb.LED(i).off() commands to control the LED's on and off ...
slotg MicroPython Open Source section
I wrote some code as a beginner. Can anyone tell me where I'm entering an infinite loop?
Write a running light from left to right and then from right to left ORG 00H START: CLR C MOV A,#0FFH RIGHT: MOV R1,#08H CALL DELAY RLC A MOV P1,A DJNZ R1,RIGHT LEFT: MOV R2,#08H CALL DELAY MOV P1,A R...
仰望的人 51mcu
Problems encountered when using capacitors to delay switching of transistors
The input voltage is VCC=6.5v, and the base input of 8050 is the cup output. How long does it take for this circuit to form a path after charging, or does it not form a path? I think it does not form ...
林发扬 Analog electronics
I want to ask for help on the stm8l152c6AD issue.
I need help with the AD problem of stm8l152c6. Two 680k resistors are connected in series to the power supply, and the middle point is connected to the AD port to detect the voltage. The midpoint volt...
33love stm32/stm8
Request WinCE5.0 system image file (.bin)
The PlatformBuilder 5.0 I downloaded always compiles incorrectly, but now I need a system for development. I hope someone can send me a compiled WinCE5.0 NK.BIN file (with serial port and USB driver)....
junxibj Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1128  1416  2602  1409  1561  23  29  53  32  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号