(1/2)
001-03 / 20030611 / ea331_crx.fm
Power Supplies
DC to DC Convertors
Non-insulation, DIP Type
SPECIFICATIONS AND STANDARDS
CRX Series
Part No.
CRX0505N
CRX0512P
CRX0512N
Maximum output power
W
0.25
0.3
0.3
Input conditions
Input voltage Edc
V
+4.5 to +5.5(+5typ.)
∗
1
%
70typ.
75typ.
70typ.
Efficiency
Output characteristics and others
Output voltage Edc
V
–5
+12
–12
Maximum output current
mA
50
25
25
Output voltage setting deviation
V
±0.4max.
±0.5max.
±0.5max.
Input variation
%
2
2
3
Voltage
%
2
2
2
Load variation
∗
2
stability
∗
3
%
5
4
7
Temperature variation
mV
100typ.
100typ.
100typ.
Ripple Ep-p
∗
4
Output capacitor Co
µF
33
10
10
∗
1
Typical input voltage, maximum output current.
∗
2
The value for the variation of 10 to 100% rated output current.
∗
3
The value when the temperature is changed from 0 to +50°C for the rated input and output.
∗
4
The value when the proper tantalum capacitor is connected to the output side.
CRX0515P
0.3
CRX0515N
0.3
75typ.
+15
20
±0.6max.
2
2
4
100typ.
10
70typ.
–15
20
±0.6max.
3
2
7
100typ.
10
OUTPUT POWER - AMBIENT TEMPERATURE(DERATING)
Derating is necessary when ambient temperature exceeds 50°C.
100
80
60
40
20
0
–20 –10 0
10 20 30 40 50 60 70 80
Ambient temperature(°C)
PRECAUTIONS
• Parallel operation to increase output current is not possible.
• Input fuse
A 0.15A fuse should be connected to the input.
• Wiring between the input power supply and the converter should
be short so as to reduce impedance as much as possible. How-
ever, if the input line impedance is high, installation of an input
capacitor is recommended.
• Install the components according to the diagram shown below.
Vin
Output power(%)
+V output
–V output
6
5
4
PACKAGING STYLE AND QUANTITY
Exclusive magazine for DC to DC converter’s packaging
(40 pieces/magazine)
Input
power
supply
+5V
C
1
+
C
2
1
C
3
GND
+
+
GND
C
1
:16V,33µF
C
2
,C
3
:16V,33µF(Vo=5V)
25V,10µF(Vo>5V)
SOLDERING CONDITIONS
Dipping: 260±5°C, 10s
CLEANING CONDITIONS
Solvent: IPA
• All specifications are subject to change without notice.
(2/2)
001-03 / 20030611 / ea331_crx.fm
Power Supplies
DC to DC Convertors
Non-insulation, DIP Type
SHAPES AND DIMENSIONS
8
6
5
CRX Series
CIRCUIT DIAGRAM
+OUT
NC
8
– OUT
6
5
TDK JAPAN
CRX-0512P
Lot no.
TDK JAPAN
CRX-0512P
Lot no.
5.08max.
1
7.8max.
1
4
4
GND
DC IN
GND
0.5
0.2
7.9 to 8.9
3
to 0.
Terminal connection
No.1
No.4
No.5
No.6
No.8
Vin(+5V input)
GND
–V output(Not connected when +V output, NC)
+V output(Not connected when –V output, NC)
NC
3min.
0.5
2.54
7.62
12.5max.
Dimensions in mm
Oscillating method: Astable frequency method
Oscillating frequency:Approx. 250kHz[100% load] to approx. 1000kHz[no load]
MTTF: 206Fit[4800000h, 100% load]
COMMON SPECIFICATIONS
Overcurrent protection
Remote ON-OFF
Temperature range
Humidity range
External dimensions
Weight
Operating(°C)
Storage(°C)
Operating(%)RH
Storage(%)RH
No
No
–20 to +70[Derating is necessary when operating environment temperature exceed 50°C.]
–40 to +85
20 to 95[Maximum wet-bulb temperature: 38°C, without dewing]
20 to 95[Maximum wet-bulb temperature: 38°C, without dewing]
12.5
×
5.08
×
7.8mm[W
×
H
×
D]