EEWORLDEEWORLDEEWORLD

Part Number

Search

HAS040YE-ANNT82V

Description
DC-DC Regulated Power Supply Module, 1 Output, 60W, Hybrid
CategoryPower/power management    The power supply circuit   
File Size91KB,3 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

HAS040YE-ANNT82V Overview

DC-DC Regulated Power Supply Module, 1 Output, 60W, Hybrid

HAS040YE-ANNT82V Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage36 V
Minimum input voltage18 V
Nominal input voltage24 V
JESD-30 codeR-XDMA-P9
JESD-609 codee0
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature100 °C
Minimum operating temperature-40 °C
Maximum output voltage3.63 V
Minimum output voltage2.97 V
Nominal output voltage3.3 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal surfaceTIN LEAD
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output60 W
Fine-tuning/adjustable outputYES
Base Number Matches1
HAS SERIES - 60 WATT
DESCRIPTION
HAS DC/DC converters are low-cost, industry standard,
half-brick converters. The HAS features 2:1 input
voltage, excellent efficiency, and open-frame packaging
technology. The HAS operates over a range of -40°C to
100°C and has a built-in input pi filter that helps to
ensure low noise operation. Available in several input
and output combinations, the HAS is designed for
industrial, telecom, and networking applications.
FEATURES
• Industry Standard
Half-Brick
• Low-Cost Design
• Open-Frame Packaging
• 100°C Baseplate
Operation
24V and 48V Inputs
Optional Enable Logic
1500V Isolation
Input Pi Filter
Efficiency vs. Load (24V Input)
90
85
EFFICIENCY%
TECHNICAL SPECIFICATIONS
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
Input Reverse Voltage Protection
Output
Setpoint Accuracy
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
Remote Sense Headroom
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I
out
Rated
OVP Trip Range
Remote Shutdown Reference
Shutdown Pin Current, Sourced at Off
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
(Bellcore TR-NWT-000332)
Safety
Weight (approx.)
REV. JUN 07, 2002
10 ms
Positive or Negative Logic
500 kHz
1500 VDC
1050 VDC
500 VDC
0.03%/°C
-40 To +100°C
-40 To +125°C
105 To 115°C
95%
5 g, 10 - 55 Hz
2.5 x 106 hrs
UL, cUL, TUV
1.4 oz
±1%
±0.2% V
out
±0.2% V
out
0.5 VDC
10 % I
out
Rated
25% I
out
4% V
out
500
µs
±10%
Hiccup
110 - 140%
115 - 140% V
out
Nom.
V
in
Negative
10 mA Max.
18 - 36 VDC
36 - 72 VDC
25 mA
Shunt Diode
80
75
70
65
60
10
20
30
40
50
60
70
80
90 100
HAS060YH-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
LOAD %
Efficiency vs. Load (48V Input)
90
85
80
EFFICIENCY %
75
70
65
60
55
50
45
10
20
30
40
50
60
70
80
90
100
LOAD %
HAS060ZH-A
EFF. (36v)
EFF. (48v)
EFF. (72v)
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
1
Why can't the PC connect to GSM?
I am using GSM now and want to test the GSM function with the PC serial port. Why is there no display in the hyperterminal? I can't input any commands on the keyboard. The baud rate is set to 9600, th...
北极光 Embedded System
MSP430_PCB
...
gaochy1126 Microcontroller MCU
【Book Collection】Electronic Technology Digital Logic Fundamentals 5th Edition
Contents: 1 Introduction to Digital Logic 1.1 Digital Circuits and Digital Signals 1.2 Number Systems 1.3 Arithmetic Operations on Binary Numbers 1.4 Binary Codes 1.5 Binary Logic Variables and Basic ...
wzt Analog electronics
How to determine the start bit of com port communication?
For example, the instrument manual says the start bit is (02), so how do you determine that 2 is the start bit? ? What if there is also data 2 in the middle, for example, the data sent is: 222222222...
ewrrwe Embedded System
C2000 DSP LaunchPad expansion board (uploaded)
[i=s] This post was last edited by Pinghu Qiuyue on 2014-5-27 09:50 [/i] I asked someone to make an expansion board for C2000 LaunchPad. I will show it to you in a few days. You can do general experim...
平湖秋月 Microcontroller MCU
Why can't the kernel be started if there are bad blocks in the kernel burning area?
[table=98%,rgb(239, 245, 249)] [tr][td]Hi everyone, the address I burned the kernel to is 0x200000, but there is a bad block at 0x280000. When I boot, it prompts bad CRC and cannot find the kernel. I ...
yanghelovehuang Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 847  1957  1440  2415  1224  18  40  29  49  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号