EEWORLDEEWORLDEEWORLD

Part Number

Search

BK8/ABC-7-R

Description
FAST BLOW ELECTRIC FUSE, 7A, 250VAC, 125VDC, 200A (IR), INLINE/HOLDER, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size205KB,2 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK8/ABC-7-R Overview

FAST BLOW ELECTRIC FUSE, 7A, 250VAC, 125VDC, 200A (IR), INLINE/HOLDER, ROHS COMPLIANT

BK8/ABC-7-R Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Is SamacsysN
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal73 J
Manufacturer's serial numberABC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current7 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
1
4
” x 1
1
4
” Glass Tube Fuses
ABC Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
1
4
” x 1
1
4
” (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
Dimensions - mm
Drawing Not to Scale
Agency Information
• UL Listed Guide JDYX & File E19180
• UL Recognition Guide JDYX2 & File E19180
• CSA Certification: Class No: 1422-01 & 1422-30,
File 53787
Environmental Data
• Shock:
1
4
A - 30A – MIL-STD-202, Method 213,
Test Condition J
• Vibration:
1
4
A - 30A – MIL-STD-202, Method 204,
Test Condition C (Except 5g, 500Hz)
Ordering
• Specify packaging, product and option code
Voltage
Ratings
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Vdc
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Vac Interrupting
Ratings* (amps)
250
125
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
200
1000
200
1000
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The
interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
Part
Number
ABC-
1
4
-R
ABC-
1
2
-R
ABC-
3
4
-R
ABC-1-R
ABC-1-
1
2
-R
ABC-2-R
ABC-2-
1
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Vdc Interrupting
Ratings (amps)
125
75
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
400
1000
400
1000
Specifications
Typical
DC Cold
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc
I
2
t AC
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (V)
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
‡‡
X X
‡‡
0613
BU-SB13635
Page 1 of 2
Data Sheet 2000
Two major power outages in five days! The Taiwan authorities have asked TSMC to relocate or suspend some production lines
On May 19, according to Taiwanese media reports, due to the increasing tension in water and electricity supply on the island, measures such as peak power rationing and "five days on, two days off" hav...
eric_wang Talking
stm32f test applet
Hope it is useful for beginners!Use the internal crystal oscillator and PC port to flash the light!stm32f.JPG(51.25 KB)Downloads:13 2010-9-28 16:41...
86846642996 stm32/stm8
PADS PCB 3D component library
Do any friends build 3D component libraries when designing PCB? Can some friends share their experience? Thank you!...
Fred_1977 PCB Design
I need help. When emulating the TMS320F28069PZT chip with CCS5.5.0, the global variables set all have random numbers in them.
I have been using CCS3.3 before. Later, I changed the chip to 28069 and updated the CCS software to 5.5.0. However, this strange phenomenon occurred during simulation. During simulation, the global va...
zyong Microcontroller MCU
AltiumDesigner adds annotations and reference numbers to specified layers
Open a PCB file under AltiumDesigner, and we can see that the position number and component value annotations on the board are placed on the top and bottom silk screens by default. We will not elabora...
okhxyyo PCB Design
Guo Tianxiang learns 51 MCU simulation board in ten days
Which foot does Hall want to stick in Guo Tianxiang? ? I want to do the pulse counting...
desperatekid 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1730  659  638  469  1433  35  14  13  10  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号