EEWORLDEEWORLDEEWORLD

Part Number

Search

D38999/26SJ19AA

Description
MIL Series Connector, 19 Contact(s), Stainless Steel, Male, Crimp Terminal, Plug,
CategoryThe connector    The connector   
File Size242KB,6 Pages
ManufacturerSOURIAU
Environmental Compliance  
Download Datasheet Parametric View All

D38999/26SJ19AA Overview

MIL Series Connector, 19 Contact(s), Stainless Steel, Male, Crimp Terminal, Plug,

D38999/26SJ19AA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSOURIAU
Reach Compliance Codecompliant
Is SamacsysN
Other featuresSTANDARD: MIL-DTL-38999, POLARIZED, RFI SHIELDED, COMPATIBLE CONTACT: M39029/58365
Back shell typeSOLID
Body/casing typePLUG
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNICKEL
Contact completed and terminatedNickel (Ni)
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Environmental characteristicsFLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialSTAINLESS STEEL
Housing sizeJ
Termination typeCRIMP
Total number of contacts19
Base Number Matches1

D38999/26SJ19AA Preview

8D - D38999 Stainless steel
MIL-DTL-38999 Serie
III
MIL-DTL-38999 Series
III
Stainless steel
33
8D - D38999 Stainless steel
Connector part numbers
Basic Series
Shell style:
0:
Square flange receptacle
1:
In line receptacle
7:
Jam nut receptacle
5:
Plug with RFI shielding.
Type:
-:
Connectors with standard crimp contacts.
L:
Receptacle with long spill (male and female size #22D, #20).
C:
Receptacle with short spill (male and female #22D, #20, #16).
S:
Receptacle with specific spill (male et female #22D)
W:
Receptacle with male contacts #22D for wire wrap (3 wraps)
T:
Receptacle with male contacts #20 for wire wrap (2 wraps)
Shell size:
09 - 11 - 13 - 15 - 17 - 19 - 21 - 23 - 25
Plating:
K:
Passivated
S:
Nickel
8D
0
-
11
K
35
P
N
**
Contact layout:
See page 8 to 11
Contact type:
P:
Pin
A:
Connector supplied less pin contact or with specific contacts (Connector marking: A+ orientation)
S:
Socket
B:
Connector supplied less socket contact or with specific contacts (Connector marking: B+ orientation)
Orientation:
N, A, B, C, D & E (See page 58)
Spécification:
046:
Tinned straight spills
251:
Connector provided with power contacts (layouts with contacts #8)
022:
Fuel tank
L:
For P or S contact type only, connectors delivered without contacts, connectors marking P or S plus orientation.
MIL-DTL 38999 part numbers*
Basic Series
Shell style:
20:
Square flange receptacle
24:
Jam nut receptacle
26:
Plug with RFI shielding.
Plating:
K:
Passivated
S:
Nickel
Shell size:
A - B - C - D - E - F - G - H - J
Contact layout:
See page 11 for layout according to MIL-DTL-38999
Contact type:
P:
Pin.
S:
Socket.
A:
Connector supplied less pin contact or with specific contacts (connector marking: A + orientation).
B:
Connector supplied less socket contact or with specific contacts (connector marking: B + orientation).
D38999 20
K
B
35
P
N
L
Orientation:
N, A, B, C, D & E (see page 58)
L:
For P or S contact type only, connector delevired without contacts, connector marking P or S (without L)
* Note:
To place an order of MIL connectors delivered without MIL removable crimp contacts and keep P or S plus orientation marking,
it must be specify clearly on the order (by adding a suffix L at the end of the P / N or specified in comment).
34
8D - D38999 Stainless steel
Dimensions
Receptacle type 0
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A
Max.
20.90
20.90
20.90
20.90
20.90
20.90
20.10
20.10
20.10
B
Max.
10.60
10.60
10.60
10.60
10.60
10.60
11.40
11.40
11.40
C
Max.
2.50
2.50
2.50
2.50
2.50
2.50
3.20
3.20
3.20
D
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
E
± 0,30
23.80
26.20
28.60
31.00
33.30
36.50
39.70
42.90
46.00
F
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
38.10
G
15.09
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
H
± 0,20
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.91
3.91
J
± 0,20
5.49
4.93
4.93
4.93
4.93
4.93
4.93
6.15
6.15
Dimensions in millimeters)
Receptacle type 7
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A + 0.10
- 0.15
16.53
19.07
23.82
26.97
30.15
33.32
36.50
39.67
42.85
B
Max.
9.90
9.90
9.90
9.90
9.90
9.90
9.90
9.90
9.90
C
Max.
3.20
3.20
3.20
3.20
3.20
3.20
3.20
3.20
3.20
D
Max.
30.50
35.20
38.40
41.60
44.80
49.50
52.70
55.90
59.00
E
Max.
23.00
26.00
31.00
34.00
37.00
41.00
46.00
47.00
52.00
F
± 0.4
27.00
31.80
34.90
38.10
41.30
46.00
49.20
52.40
55.60
G
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
Dimensions in millimeters
35
8D - D38999 Stainless steel
In line receptacle type 1
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
D
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
ØF
15.90
19.05
22.25
25.40
30.15
31.75
34.75
37.10
41.30
Plug type 5
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A
Max.
31.00
31.00
31.00
31.00
31.00
31.00
31.00
31.00
31.00
B
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
C
Max.
21.80
25.00
29.40
32.50
35.70
38.50
41.70
44.90
48.00
Maximum coupling torque on panel for jam nut receptacle (type 7)
Shell
Coupling
torque
(N.m)
09
(A)
6
11
(B)
8
13
(C)
10
15
(D)
13
17
(E)
20
19
(F)
23
21
(G)
25
23
(H)
26
25
(J)
28
Mated connectors dimensions
Type 0 with plug
Type 7 with plug
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A
Max.
37.00
37.00
37.00
37.00
37.00
37.00
36.00
36.00
36.00
B
Max.
52.30
52.30
52.30
52.30
52.30
52.30
51.30
51.30
51.30
C
Max.
38.30
38.30
38.50
38.50
38.50
38.50
38.50
38.50
38.50
D
Max.
53.60
53.60
53.80
53.80
53.80
53.80
53.80
53.80
53.80
Dimensions in millimeters
36
8D - D38999 Stainless steel
Receptacle with straight spill contacts
Shell size
Contact size
A
# 22D
# 22D
# 20
# 16
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 20
# 20
# 20
# 20
# 16
# 16
# 16
# 16
# 22D
# 22D
# 22D
# 20
# 16
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 20
# 20
# 20
# 20
# 16
# 16
# 16
# 16
Contact type
M&F
M&F
M&F
M&F
M
M
F
F
M
M
F
F
M
M
F
F
M
M
F
F
M&F
M&F
M&F
M&F
M&F
M
M
F
F
M
M
F
F
M
M
F
F
M
M
F
F
Spill type
L&C
S
C
C
L&C
L&C
L&C
L&C
S
S
S
S
C
C
C
C
C
C
C
C
L
C
S
C
C
L&C
L&C
L&C
L&C
S
S
S
S
C
C
C
C
C
C
C
C
L:
Long spill
09
(A)
11
(B)
13
(C)
15
(D)
17
(E)
0,70
0.50
0.70
1.15
19
(F)
21
(G)
23
(H)
25
(J)
L2
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
10.52
11.46
10.19
11.46
10.69
11.63
10.36
11.63
10.69
11.63
10.69
11.63
10.69
11.63
10.69
11.63
8.50
4.00
5.10
5.10
5.10
9.48
10.58
9.15
10.58
9.65
10.75
9.15
10.75
9.65
10.75
9.65
10.75
9.65
10.75
9.65
10.75
C :
Short spill
S:
Specific spill
10.34
11.28
10.01
11.28
10.51
11.45
10.18
11.45
10.51
11.45
10.51
11.45
10.51
11.45
10.51
11.45
L3
L4
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
9.59
10.69
9.26
10.69
9.76
10.86
9.26
10.86
9.76
10.86
9.76
10.86
9.76
10.86
9.76
10.86
M :
Male contact
Dimensions in millimeters
F:
Female contact
37
[2011 National Competition Question Discussion Post] Question C: Smart Car
The 2011 National College Student Contest has been published. If you have any questions about Question C , you can post them here ! We look forward to the enthusiastic friends in the forum to help you...
EEWORLD社区 Electronics Design Contest
How to determine whether a program is already running under WinCE?
I referred to some desktop solutions and found that none of them can be used under CE4.2. Either the mutex function does not support multiple parameters, or the Process class cannot be used. Can anyon...
kertina Embedded System
Looking for the driver and burning software for lm3s811 chip ft2232 burning
Could you please send me a copy? Thank you. I would like to ask you for advice in the long term! [email]704114178@qq.com[/email]...
citymoon Microcontroller MCU
Problems with using DM9000 in embedded industrial control products
My embedded product uses DM9000a. I can ping it with one computer (occasionally with packet loss). When I switch to another computer without power failure, sometimes I can ping it, sometimes I can't. ...
xuliqun Embedded System
Asking for advice on the capture of TIMERA
The chip used is 413,and the TA1 capture mode is used to measure the frequency period from the P1.2 port. The buttons are used on the test board to simulate the pulse signal to be tested. It is found ...
wangtong0819 Microcontroller MCU
What is the problem with the USB host program not being able to enumerate?
[code]case HOST_ENUMERATION:/* Check for enumeration status */if ( USBH_HandleEnum(pdev , phost) == USBH_OK){/* The function shall return USBH_OK when full enumeration is complete *//* user callback f...
770781327 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2903  406  1412  2798  2053  59  9  29  57  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号