ISOLATION SPECIFICATIONS
Item
Isolation voltage
Isolation resistance
Test condition
Tested for 1 minute
Test at 500VDC
Min
3000
1000
Typ
Max
Units
VDC
MΩ
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
IF_S(D)-1W
A/2-2011
Page 1 of 3
OUTPUT SPECIFICATIONS
Item
Output power
Line regulation
Load regulation
Output voltage accuracy
Temperature drift
Output ripple*
Output noise*
Switching frequency
For Vin change of
±5%
10% to 100% full load
100% full load
100% full load
20MHz bandwidth
20MHz bandwidth
Full load, nominal input voltage
10
50
100
Test condition
Min
0.1
Typ
Max
1
±0.25
±1
±3
0.03
20
100
KHz
%/°C
mVp-p
%
Units
W
TYPICAL CHARECTERISTICS
Temperature Derating Graph
*
Test ripple and noise by
“parallel
cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Operating Temp.(
C
)
COMMON SPECIFICATIONS
Item
Storage humidity range
No-load power consumption
Storage humidity range
Operating temp. range
Temp. rise at full load
Lead temperature
Short circuit protection
Cooling
Case material
MTBF
3500
1.5mm from case for 10 seconds
IFXX05S/D-1W*
Others
-55
-40
15
10
125
85
25
300
1
Continuous
Free air convection
Plastic (UL94-V0)
K hours
S
°C
Test condition
Min
Typ Max
95
Units
%
*
Supply voltage must be discontinued at the end of short circuit duration.
APPLICATION NOTE
①
Requirement On Output Load
To ensure this module can operate efficiently and reliably, a minimum load is specified for this
kind of DC/DC converter in addition to a maximum load (namely full load). During operation,
make sure the specified range of input voltage is not exceeded, the minimum output load
could
not be less than 10% of the full load.
If the actual output power is very small, please connect
a resistor with proper resistance at the output end in parallel to increase the load, or use our
company’s products with a lower rated output power (IF_S(D)
–W25
Series).
RECOMMENDED CIRCUIT
L
L
Vin
C
+Vo
DC DC
(Figure 1)
C
GND
0V
EXTERNAL CAPACITOR TABLE (TABLE 1)
②
Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to
the DC/DC output end and input end to reduce the noise and ripple. However, the capacitance
of the output filter capacitor must proper. If the capacitance is too big, a startup problem might
arise. For every channel of output, providing the safe and reliable operation is ensured, the
greatest capacitance of its filter capacitor refer to (Table 1).
To get an extremely low ripple, an
“LC”
filtering network may be connected to the input and
output ends of the DC/DC converter, which may produce a more significant filtering effect. It
should also be noted that the inductance and the frequency of the
“LC”
filtering network should
be staggered with the DC/DC frequency to avoid mutual interference (Figure 1).
Vin
(VDC)
5
12
24
-
Cin
(
μF
)
4.7
2.2
1
-
Vout
(VDC)
5
9
12
15
Cout
(
μF
)
10
4.7
2.2
1
It’s not recommended to connect any external capacitor
in the application field with less than 0.5 watt output.
③
Overload Protection
Under normal operating conditions, the output circuit of these products has no protection
against over-current .The simplest method is to connect a self-recovery fuse in series at the
input end or add a circuit breaker to the circuit.
④
When the environment temperature is higher than 71°C, the product output power
should be less then 60% of the rated power.
⑤
No parallel connection or plug and play.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
IF_S(D)-1W
A/2-2011
Page 2 of 3
OUTLINE DIMENSIONS& RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
IF_S-1W Series SIP Package
RECOMMENDED FOOTPRINT
12.70
[0.500]
7.62
[0.300]
∅
1.00[
∅
0.039]
1 2
4
6
6.00[0.236]
∅
1.00[
∅
0.039]
15 .70
[0. 618]
7.62
[0.300]
10.00
[0.394]
0.50[0.020]
19.60[0.772]
(Front View)
10.00
[0.394]
2.54[0.100]
2.18[0.086]
0.90 [0.035]
7.62
[0.300]
12.70
[0.500]
4.10[0.161]
2.18[0.086]
2.54[0.100]
19.60[0.772]
Note
:
Grid:2.54*2.54mm
.
TUBE OUTLINE DIMENSIONS
1 2
0.90 [0.035]
(Bottom View)
4
6
9.40
[0.370]
0.30[0.012]
6.00 [0.236]
12.20
[0.480]
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
FOOTPRINT DETAILS
Pin
1
2
4
6
Function
Vin
GND
0V
+Vo
Note:
4.70[0.185]
Unit :mm[inch]
General tolerances:
±0.50mm[±0.020inch]
L=530mm[20.866inch] Devices per tube quantity: 25pcs
L=220mm[8.661inch] Devices per tube quantity: 10pcs
Short tube inner packaging dimensions: L*W*H=255*170*80mm
Short tube outer packaging dimensions: L*W*H=375*280*270mm
Long tube inner packaging dimensions: L*W*H=580*200*100mm
Long tube outer packaging dimensions(with two inner packaging boxes):
L*W*H=600*215*220mm
Long tube outer packaging dimensions(with three inner packaging boxes):
L*W*H=600*215*325mm
MECHANICAL DIMENSIONS
IF_D-1W Series DIP package
RECOMMENDED FOOTPRINT
0. 50[0.020]
(
Front View
)
7.00
[0.276]
20.00[0.787]
12.70
[0.500]
5.08[0.200]
14
4.10[0 .161]
16.70
[0.657]
0.50[0.020]
11
9
7
15.24[0.600]
20.00[0.787]
15.24[0.600]
1
7
(
Bottom View
)
14
11
9
7.62
[0.300]
10.00
[0.394]
0.30[0.012]
TUBE OUTLINE DIMENSIONS
12.00
[0.472]
9.60
[0.37 8]
0.50[0.020]
7.62
[0.300]
12.70
[0.500]
Note:
Unit:m m[inch]
Pin section tolerances:±0.10mm [±0.004inch]
General tolerances:±0.25m m[±0.010inch]
FOOTPRINT DETAILS
Pin
1
7
9
11
14
Function
GND
NC
+Vo
0V
Vin
NC
:
No connection
Note:
5.30[0.209]
Unit :mm[inch]
General tolerances:
±0.50mm[±0.020inch]
L=530mm[20.866inch] Devices per tube quantity: 25pcs
L=220mm[8.661inch] Devices per tube quantity: 10pcs
Short tube inner packaging dimensions: L*W*H=255*170*80mm
Short tube outer packaging dimensions: L*W*H=375*280*270mm
Long tube inner packaging dimensions: L*W*H=580*200*100mm
Long tube outer packaging dimensions(with two inner packaging boxes):
L*W*H=600*215*220mm
Long tube outer packaging dimensions(with three inner packaging boxes):
L*W*H=600*215*325mm
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
2. See below recommended circuits for more details.
3. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the life of product.
The copyright and authority for the interpretation of the products are reserved by MORNSUN