3W, Ultra-Wide Input Range DIP, Single & Dual Output DC/DC Converters
Key Features
Efficiency up to 83%
4200VDC Isolation
MTBF > 1,000,000 Hours
4:1 Wide Input Range
Complies With EN55022 Class B
All I/O Clearance and Creepage Distance
2.0 mm Min.
Temperature Performance -40] to +75]
Low Leakage Current
Low Isolation Capacitance
Meets UL1950/EN60950
MIW2100-Series power modules are specially designed to
provide ultra-high levels of isolation 4200VDC in a low profile 24-pin DIP
package. Operating input voltage ranges of 9-40VDC, 18-80VDC and
36-160VDC which provide precisely regulated output voltages of 5V,
12V, {12V and {15VDC.
The -40] to +75] operating temperature range makes it ideal for
data communication equipments, mobile battery driven equipments,
distributed power systems, telecommunication equipments, mixed
analog/digital subsystems, process/machine control equipments,
computer peripheral systems and industrial robot systems.
The modules have a maximum power rating of 3W and a typical
full-load efficiency of 83%, continuous short circuit, EN55022 Class B
conducted noise compliance minimize design-in time, cost and eliminate
the need for external filtering.
Low Profile
Wide Range
4:1
4200
VDC
I/O Isolation
EMI
EN55022
Block Diagram
Single Output
Dual Output
+Vin
LC
Filter
+Vo
+Vin
LC
Filter
+Vo
Com.
-Vo
PWM
Isolation
Ref.Amp
PWM
Isolation
Ref.Amp
-Vo
-Vin
-Vin
MIW2100 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
Input Current
Reflected
Ripple
Current
mA (Typ.)
Efficiency
VDC
MIW2122
MIW2123
MIW2126
MIW2127
MIW2132
MIW2133
MIW2136
MIW2137
MIW2142
MIW2143
MIW2146
MIW2147
110
( 36 ~ 160 )
48
( 18 ~ 80 )
24
( 9 ~ 40 )
VDC
5
12
{12
{15
5
12
{12
{15
5
12
{12
{15
Max.
mA
600
250
{125
{100
600
250
{125
{100
600
250
{125
{100
Min.
mA
90
37.5
{18.8
{15
90
37.5
{18.8
{15
90
37.5
{18.8
{15
@Max. Load
mA (Typ.)
160
151
151
151
80
75
75
75
35
33
33
33
@No Load
mA (Typ.)
@Max. Load
% (Typ.)
78
83
83
83
78
83
83
83
78
83
83
83
20
15
10
8
5
3
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
24VDC Input Models
48VDC Input Models
110VDC Input Models
Min.
-0.7
-0.7
-0.7
---
---
Max.
50
100
180
260
2,500
Unit
VDC
VDC
VDC
]
mW
Notes :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 75%
to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum output
loading to maintain specified regulation.
5. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
6. All DC/DC converters should be externally fused at
the front end for protection.
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions
Ambient
Case
Min.
-40
-40
-40
---
Free-Air Convection
EN55022 Class B
Max.
+75
+95
+125
95
Unit
]
]
]
%
7. Other input and output voltage may be available,
please contact factory.
8. Specifications subject to change without notice.
MIW2100 Series
Input Specifications
Parameter
Start Voltage
Model
24V Input Models
48V Input Models
110V Input Models
Under Voltage Shutdown
24V Input Models
48V Input Models
110V Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
All Models
Min.
8
13
26
---
---
---
---
---
Typ.
8.5
15
30
---
---
---
---
---
Pi Filter
Max.
9
17
34
8.5
16
32
0.3
2000
A
mW
VDC
Unit
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
25% Load Step Change
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=100% to 25%
5V Output Models
Other Output Models
Over Line, Load & Temp.
Conditions
Min.
---
---
---
---
---
---
---
---
120
---
---
---
Continuous
Typ.
{0.5
{0.5
{0.3
{0.5
75
100
---
---
---
150
{3
{0.02
Max.
{1.0
{2.0
{0.5
{1.0
100
150
180
15
---
500
{6
{0.05
Unit
%
%
%
%
mV P-P
mV P-P
mV P-P
mV rms
%
uS
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
MIL-HDBK-217F @ 25], Ground Benign
Conditions
60 Seconds
Flash Tested for 1 Second
240VAC, 60Hz
500VDC
100KHz,1V
Min.
4200
5000
---
1000
---
---
1000
Typ.
---
---
---
---
7
150
---
Max.
---
---
2
---
13
---
---
Unit
VDC
VDC
uA
M[
pF
KHz
K Hours
Capacitive Load
Models by Vout
Maximum Capacitive Load
# For each output
5V
1000
12V
470
{12V
#
220
{15V
#
220
Unit
uF
Input Fuse Selection Guide
24V Input Models
1000mA Slow - Blow Type
48V Input Models
500mA Slow - Blow Type
110V Input Models
300mA Slow - Blow Type
MIW2100 Series
Input Voltage Transient Rating
320
300
280
260
240
220
Vin ( VDC )
200
180
160
140
120
100
80
60
40
0
10uS
100uS
1mS
10mS
100mS
24VDC Input Models
48VDC Input Models
110VDC Input Models
MIW2100 Series
100
90
Efficiency (%)
Efficiency (%)
80
70
60
50
100
90
80
70
60
50
Low
Nom
Input Voltage (V)
High
Low
Nom
Input Voltage (V)
High
Efficiency vs Input Voltage ( Single Output )
Efficiency vs Input Voltage ( Dual Output )
90
80
70
100
90
Efficiency (%)
80
70
60
50
40
10
20
40
60
Load Current (%)
80
100
Efficiency (%)
60
50
40
30
20
30
10
20
40
60
80
100
Load Current (%)
Efficiency vs Output Load ( Single Output )
Efficiency vs Output Load ( Dual Output )
100
80
Output Power (%)
100LFM
Natural
convection
400LFM
200LFM
60
40
20
0
-40
〜
50
60
70
80
]
90
100
110
Ambient Temperature
Derating Curve