IM-10RFCM-13
Vishay Dale
Inductors
Commercial, Molded
FEATURES
•
Inductance range is 1µH to 2200µH.
•
Proven reliability molded inductors.
STANDARD ELECTRICAL SPECIFICATIONS
MODEL*
IND.
(
µ
H)
TEST SRF DCR RATED DC
Q FREQ. MIN. MAX. CURRENT
TOL. MIN. (MHz) (MHz) (Ohms) (mA)
±
10% 100
±
10% 100
±
10% 100
±
10% 95
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
10%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
±
5%
95
68
60
60
60
65
70
65
65
65
75
65
65
65
80
80
100
100
100
100
100
95
90
85
85
80
80
75
75
65
65
65
70
60
70
15
15
10
10
10
7.9
7.9
7.9
7.9
7.9
7.9
7.9
5
5
4
4
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
1.5
1.5
1
1
1
1
0.80
0.80
0.80
0.80
0.80
0.80
0.50
0.25
0.25
136
124
112
100
88
76
72
70
60
56
52
46
40
36
32
30
28
25
22
20
19
18
16
14
13
11
9
7
5.5
4.5
3.5
3.0
2.8
2.5
2.2
2.0
1.8
2.2
1.6
0.04
0.04
0.04
0.05
0.05
0.05
0.05
0.07
0.09
0.14
0.17
0.25
0.32
0.47
0.62
0.72
0.80
1.2
1.5
2.3
3.0
4.2
5.2
6.2
7.0
7.5
8
9
10
11
12
13
14
16
17
19
21
22
30
2700
2700
2700
2500
2500
2500
2500
2100
1800
1550
1300
1150
1000
870
730
660
600
520
450
380
300
270
250
220
200
200
190
185
180
172
165
157
150
145
140
132
125
120
100
ELECTRICAL SPECIFICATIONS
Inductance Tolerance:
±
10% on Q-Meter for 1µH to 22µH.
±
5% 1000 cps bridge for 27µH to 2200µH.
NOTE:
L and Q are not always tested at the same frequency.
Inductance values tested on Q-Meter, are tested at standard
test frequencies.
Dielectric Strength:
700VRMS at sea level.
Operating Temperature:
- 55°C to + 125°C.
Self-Resonant Frequency:
Minimum SRF measured with full
length leads on Grid-Dip Meter.
Q:
Measured on Q-Meter.
Rating:
1/3 watt dissipation for M Models.
IM-10RFCM-13 1.0
IM-10RFCM-13 1.2
IM-10RFCM-13 1.5
IM-10RFCM-13 1.8
IM-10RFCM-13 2.2
IM-10RFCM-13 2.7
IM-10RFCM-13 3.3
IM-10RFCM-13 3.9
IM-10RFCM-13 4.7
IM-10RFCM-13 5.6
IM-10RFCM-13 6.8
IM-10RFCM-13 8.2
IM-10RFCM-13 10
IM-10RFCM-13 12
IM-10RFCM-13 15
IM-10RFCM-13 18
IM-10RFCM-13 22
IM-10RFCM-13 27
IM-10RFCM-13 33
IM-10RFCM-13 39
IM-10RFCM-13 47
IM-10RFCM-13 56
IM-10RFCM-13 68
IM-10RFCM-13 82
IM-10RFCM-13 100
IM-10RFCM-13 120
IM-10RFCM-13 150
IM-10RFCM-13 180
IM-10RFCM-13 220
IM-10RFCM-13 270
IM-10RFCM-13 330
IM-10RFCM-13 390
IM-10RFCM-13 470
IM-10RFCM-13 560
IM-10RFCM-13 680
IM-10RFCM-13 820
MECHANICAL SPECIFICATIONS
Terminal Strength:
Meets 5 pound pull test when tested per
MIL-PRF-15305.
DENSITY SPECIFICATIONS
Weight:
2 grams maximum.
ENVIRONMENTAL SPECIFICATIONS
IRON CORE
Moisture:
Meets requirements of MIL-PRF-15305.
Shock Resistance:
Meets requirements of MIL-PRF-15305.
Vibration:
High frequency, 10 Hz to 2000 Hz @ 20 G
±
10%
maximum for 12 logarithmic swings, each of 20 minute duration
repeated for each of three mutually perpendicular planes.
DIMENSIONS
in inches [millimeters]
1.30 [33.02]
Typ. Min.
.250 [6.35]
Dia. Max.
#21 .028
±
.002
[.711
±
.051] TCW
.600 [15.24]
Max.
MARKING
— Color coded
ORDERING INFORMATION
IM-10RFCM-13
MODEL
1.0
µ
H
INDUCTANCE
VALUE
IM-10RFCM-13 1000
±
5%
IM-10RFCM-13 1200
±
5%
IM-10RFCM-13 2200
±
5%
±
10%
INDUCTANCE
TOLERANCE
*Model electricals and tolerances shown.
Document Number 34037
Revision 19-Oct-04
For technical questions, contact Magnetics@vishay.com
www.vishay.com
13
Legal Disclaimer Notice
Vishay
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.
Document Number: 91000
Revision: 08-Apr-05
www.vishay.com
1