MIL–PRF (CWR Style) Established Reliability – T409 Series CWR09 Style MIL–PRF–55365/4
Table 1 – Ratings & Part Number Reference
Rated
Voltage
V
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
V
Rated
Cap
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
0.33
0.68
1
1.5
2.2
4.7
6.8
µF
Case Code/
Case Size
KEMET/EIA
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T409A225(1)004(2)(3)(4)
T409B475(1)004(2)(3)(4)
T409C685(1)004(2)(3)(4)
T409D106(1)004(2)(3)(4)
T409E156(1)004(2)(3)(4)
T409F336(1)004(2)(3)(4)
T409G686(1)004(2)(3)(4)
T409H107(1)004(2)(3)(4)
T409A155(1)006(2)(3)(4)
T409B335(1)006(2)(3)(4)
T409C475(1)006(2)(3)(4)
T409D685(1)006(2)(3)(4)
T409E106(1)006(2)(3)(4)
T409F226(1)006(2)(3)(4)
T409G476(1)006(2)(3)(4)
T409H686(1)006(2)(3)(4)
T409A105(1)010(2)(3)(4)
T409B225(1)010(2)(3)(4)
T409C335(1)010(2)(3)(4)
T409D475(1)010(2)(3)(4)
T409E685(1)010(2)(3)(4)
T409F156(1)010(2)(3)(4)
T409G336(1)010(2)(3)(4)
T409H476(1)010(2)(3)(4)
T409A684(1)015(2)(3)(4)
T409B155(1)015(2)(3)(4)
T409C225(1)015(2)(3)(4)
T409D335(1)015(2)(3)(4)
T409E475(1)015(2)(3)(4)
T409F106(1)015(2)(3)(4)
T409G226(1)015(2)(3)(4)
T409H336(1)015(2)(3)(4)
T409A474(1)020(2)(3)(4)
T409B684(1)020(2)(3)(4)
T409B105(1)020(2)(3)(4)
T409C155(1)020(2)(3)(4)
T409D225(1)020(2)(3)(4)
T409E335(1)020(2)(3)(4)
T409F685(1)020(2)(3)(4)
T409G156(1)020(2)(3)(4)
T409H226(1)020(2)(3)(4)
T409A334(1)025(2)(3)(4)
T409B684(1)025(2)(3)(4)
T409C105(1)025(2)(3)(4)
T409D155(1)025(2)(3)(4)
T409E225(1)025(2)(3)(4)
T409F475(1)025(2)(3)(4)
T409G685(1)025(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/4
Part Number
(See below for
part options)
CWR09C(3)225(1)(2)(5)
CWR09C(3)475(1)(2)(5)
CWR09C(3)685(1)(2)(5)
CWR09C(3)106(1)(2)(5)
CWR09C(3)156(1)(2)(5)
CWR09C(3)336(1)(2)(5)
CWR09C(3)686(1)(2)(5)
CWR09C(3)107(1)(2)(5)
CWR09D(3)155(1)(2)(5)
CWR09D(3)335(1)(2)(5)
CWR09D(3)475(1)(2)(5)
CWR09D(3)685(1)(2)(5)
CWR09D(3)106(1)(2)(5)
CWR09D(3)226(1)(2)(5)
CWR09D(3)476(1)(2)(5)
CWR09D(3)686(1)(2)(5)
CWR09F(3)105(1)(2)(5)
CWR09F(3)225(1)(2)(5)
CWR09F(3)335(1)(2)(5)
CWR09F(3)475(1)(2)(5)
CWR09F(3)685(1)(2)(5)
CWR09F(3)156(1)(2)(5)
CWR09F(3)336(1)(2)(5)
CWR09F(3)476(1)(2)(5)
CWR09H(3)684(1)(2)(5)
CWR09H(3)155(1)(2)(5)
CWR09H(3)225(1)(2)(5)
CWR09H(3)335(1)(2)(5)
CWR09H(3)475(1)(2)(5)
CWR09H(3)106(1)(2)(5)
CWR09H(3)226(1)(2)(5)
CWR09H(3)336(1)(2)(5)
CWR09J(3)474(1)(2)(5)
CWR09J(3)684(1)(2)(5)
CWR09J(3)105(1)(2)(5)
CWR09J(3)155(1)(2)(5)
CWR09J(3)225(1)(2)(5)
CWR09J(3)335(1)(2)(5)
CWR09J(3)685(1)(2)(5)
CWR09J(3)156(1)(2)(5)
CWR09J(3)226(1)(2)(5)
CWR09K(3)334(1)(2)(5)
CWR09K(3)684(1)(2)(5)
CWR09K(3)105(1)(2)(5)
CWR09K(3)155(1)(2)(5)
CWR09K(3)225(1)(2)(5)
CWR09K(3)475(1)(2)(5)
CWR09K(3)685(1)(2)(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Maximum/5
Minutes
1
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
5.0
1.0
1.0
1.0
1.0
1.0
2.0
4.0
5.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
µA @ +20ºC
Maximum/5
Minutes
DF
% @ +20ºC
120 Hz
Maximum
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
% @ +20ºC
120 Hz
Maximum
ESR
Ω @ +20ºC
100 kHz
Maximum
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
Ω @ +20ºC
100 kHz
Maximum
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
MIL-PRF-55365/4
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates termination finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, or C = -55°C +85°C before Weibull. Designates surge current
option. Refer to Ordering Information for additional detail.
int a, b; a = dataGrid1.CurrentCell.ColumnNumber; b = dataGrid1.CurrentCell.RowNumber; dataGrid1[b, a] = textBox1.Text; SqlCeConnection conn = new SqlCeConnection("Data Source=Test.sdf"); conn. Open()...
Remove R12 from the figure, and the voltage at the red arrow is 0V when there is a signal input at IN, and 5V when there is no signal input. The circuit is normal. When R12 is connected, the voltage a...
In complex.h, why do I always get incorrect results when I use the functions defined therein: _Fcomplex (_FCmulcc)(_Fcomplex, _Fcomplex); _Fcomplex (_FCaddcc)(_Fcomplex, _Fcomplex); _Fcomplex (_FCsubc...
After working for a long time, it is inevitable that I have some ideas, and I always want to do something of my own. I have been thinking about this problem since 2010. At that time, AVR 8-bit chips w...
Today's computer peripherals are pursuing high speed and high versatility. In order to meet user needs, seven companies led by Intel launched the USB (Universal Serial Bus) bus protocol in 1994, wh...[Details]
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
In recent years, the market for mobile/portable devices such as smartphones and laptops has continued to grow rapidly. While these products continue to integrate more new features to enhance the ...[Details]
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
1. Introduction
Light control circuit plays a vital role in urban street lamps or corridor lighting. With light control circuit, the lights can be automatically turned on and off according to ...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
The solidification and modularization of intelligent video analysis algorithms are the current trends in the application of intelligent video analysis technology. It perfectly combines intelligent ...[Details]
0 Introduction
With the development of society, people pay more and more attention to security work. Monitoring products have been used in various fields instead of being used only in importan...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Vertical cavity surface emitting lasers (VCSELs) are gradually replacing traditional edge emitting lasers, especially in low bandwidth and short-distance communication systems where cost factors ar...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]