EEWORLDEEWORLDEEWORLD

Part Number

Search

REC20-4805SRW/H/CTRL

Description
Analog Circuit
CategoryAnalog mixed-signal IC    The signal circuit   
File Size80KB,2 Pages
ManufacturerRECOM
Download Datasheet Parametric Compare View All

REC20-4805SRW/H/CTRL Overview

Analog Circuit

REC20-4805SRW/H/CTRL Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codecompliant
Base Number Matches1
Features
Regulated
Converters
20W 1”x 2” Package (50.1x25.4x10.8mm)
1.6kVDC Isolation
Wide Input 2:1
Regulated Output
UL94V-0 Package Material
Continuous Short Circuit Protection
Remote ON/OFF-Control for Single Types
Efficiency to 87%
ECONOLINE
DC/DC-Converter
REC20-
SRW/H
Series
20 Watt
1” x 2”
Single
Output
Selection Guide
Part
Number
1” x 2”
REC20-xx2.5SRW/H
REC20-xx3.3SRW/H
REC20-xx05SRW/H
2:1
xx = 18-36Vin = 24
xx = 36-75Vin = 48
Input
Voltage
(VDC)
18-36, 36-75
18-36, 36-75
18-36, 36-75
Output
Voltage
(VDC)
2.5
3.3
5
Output
Current
(mA)
4000
4000
4000
(%)
83
86
87
Efficiency
* add suffix "CTRL" for optional Remote ON/OFF-Control
Specifications
(Core Operating Area)
Input Voltage Range
Input Filter
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation (10% to 100% full load )
Ripple
Noise
Operating Frequency
Over Power Protection
Over Voltage Protection
Short Circuit Protection
Transient Response
Efficiency at Full Load
Isolation Voltage
Rated Working Voltage
Isolation Capacitance
Isolation Resistance
Operating Temperature Range (Natural convection) (with derating)
Storage Temperature Range
Case Temperature
Temperature Coefficient
Relative Humidity
Case Material
Cooling Method
Package Weight
EMI (Conducted & Radiated Emission)
MTBF (+25°C)
Detailed Information see
(+40°C)
Application Notes chapter "MTBF"
MSL Level 1
2:1
π
type
±2% max.
±0.5% max.
±1% max.
110mVp-p max.
200mVp-p max.
400kHz typ.
Works over 120% of rating and recovers automatically
Zener diode clamp
Current limit, auto-recovery
500 us (100% to 50% full load at ±1% error band)
(tested for 1 second)
(long term isolation)
87% max.
1600VDC min.
see Application Notes
1000pF
100 MΩ min.
-25°C to +70°C (see Graph)
-55°C to +105°C
+100°C max.
±0.02%/°C
95% RH
Natural convection
32g
EN 55022 class A
>550 x 10
3
hours
193 x 10
3
hours
www.recom-international.com
Nickel-Plated Copper with Non-Conductive Base, Six-side Shielded
Designed to meet EN-60950-1
UL-60950-1 Pending
Derating-Graph
(Ambient Temperature)
120
100
Output Power (%)
80
60
40
20
0
Safe Operating Area
-25
0
25
40
50
70
75
100
Operating Temperature (°C)
}
using MIL-HDBK 217F
using MIL-HDBK 217F
July-2006
128

REC20-4805SRW/H/CTRL Related Products

REC20-4805SRW/H/CTRL REC20-2405SRW/H/CTRL REC20-242.5SRW/H REC20-243.3SRW/H/CTRL REC20-482.5SRW/H REC20-483.3SRW/H
Description Analog Circuit Analog Circuit Analog Circuit Analog Circuit Analog Circuit Analog Circuit
Reach Compliance Code compliant compliant compliant compliant compliant compliant
Base Number Matches 1 1 1 1 1 1
MSP430JTAG Schematic
Very good, I'm interested in making one myself...
3171068906 Test/Measurement
ESP32 Arduino 2.0.3 has been released
The Arduino 2.0.3 ESP32 core based on the ESP-IDF 4.4.1 software development kit has been released.https://github.com/espressif/arduino-esp32/discussions/6684...
dcexpert DIY/Open Source Hardware
Can DfuSe read the chip contents of STM32?
Hello everyone,I used serial ISP to burn IAP (DfuSe needs to communicate with it) on STM32, and read-protected STM32.Then I used DfuSe software to update my user program (APP).It can be read-protected...
winning stm32/stm8
RV MDK development tool video (classic) series...
Below is a video explanation of the RV MDK microcontroller development platform that I downloaded.It provides detailed guidance on the RV MDK development tools used domestically and internationally, a...
shilaike Microcontroller MCU
pspice study notes - circuit simulation process
[b]Basic process of circuit simulation: [/b] [b]1. Create a new design project; [/b] [b]2. Generate circuit diagram; [/b] [b]3. Set circuit characteristics analysis type and analysis parameters; [/b] ...
fish001 Analogue and Mixed Signal
What is your understanding of Article 82 of the Labor Contract Law of the People’s Republic of China?
[i=s]This post was last edited by yhyworld on 2020-4-19 22:00[/i]The following figure shows Article 82 of the Labor Contract Law of the People's Republic of China.On March 25 this year, the company fo...
yhyworld Talking about work

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2065  995  2015  2482  1302  42  21  41  50  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号