VDE
TV-15, 30 AMP (1 Form A)
Power Relay
HE-RELAYS
50
1.969
33
1.299
FEATURES
• High contact capacity with superior inrush current characteristics;
Rating
TV rating
1 Form A
30 A 277 V AC
TV-15
2 Form A
25 A 277 V AC
TV-10
35.8
1.409
mm
inch
• Excellent high heat-resistance;
• High dielectric strength: 10,000 V surge Conforming to VDE0806
(Insulation gap: 8 mm
.315 inch)
VDE, TÜV also approved
SPECIFICATIONS
Contacts
Type
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Nominal
switching capacity
Rating
(resistive)
Max. switching
power
Max. switching
voltage
Max. switching
current
Mechanical
(at 180 cpm)
Electrical
(at 20 cpm)
DC coil type
1a
AC coil type
2a
Maximum operating speed
Initial insulation resistance*
1
Between open contacts
Initial
Between contacts and
breakdown coil
voltage*
2
Between contact sets
(2a)
Surge voltage between coil
and contact*
3
Operate time*
4
(at nominal voltage)
25 A
Release time*
4
(at nominal voltage)
Temperature rise, max.
(resistive load)(at 55
°
C)
Shock resistance
Functional*
5
Destructive*
6
Functional*
7
Vibration resistance
Destructive
Conditions for opera-
tion, transport and
storage*
8
(Not freezing
and condensing at low
temperature)
Unit weight
Ambient
temp.
Humidity
Air pressure
2a
1a
Silver alloy
100 m
Ω
30 A
277 V
AC
8,310
VA
25 A
277 V
AC
6,925
VA
30 A
277 V
AC
8,310
VA
25 A
277 V
AC
6,925
VA
Characteristics
DC coil type
AC coil type
20 cpm
Min. 1,000 M
Ω
at 500 V DC
2,000 Vrms for 1 min.
5,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Approx. 20 ms
Approx. 5 ms Approx. 20 ms
60
°
C
65
°
C
277 V AC, 30 V DC
30 A
10
7
25 A
30 A
Expected
life (min.
operations)
5
×
10
6
10
5
(1a: 30 A 277 V AC, 2a: 25 A 277 V AC)
2
×
10
5
(1a: 30 A 250 V AC, 2a: 20 A 250 V AC)
Coil (at 20
°
C
68
°
F)
Nominal operating power
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Wave is standard shock voltage of
±
1.2
×
50
µ
s according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s
*
6
Half-wave pulse of sine wave: 6ms
*
7
Detection time: 10
µ
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
98 m/s
2
{10 G}
980 m/s
2
{100 G}
10 to 55 Hz
at double amplitude of 1 mm
10 to 55 Hz
at double amplitude of 1.5 mm
–50
°
C to +55
°
C
–58
°
F to +131
°
F
5 to 85% R.H.
86 to 106 kPa
Approx. 90 g
3.17 oz
(Plug-in type)
DC coil type
1.92 W
AC coil type
See Coil data (next page)
TYPICAL
APPLICATIONS
1. Home appliances
• Air conditioners
• Microwave ovens
• TV sets
• Heaters
• Stereo
2. Office equipment
• Copiers
• Vending machines
ORDERING INFORMATION
HE
Contact arrangement
1a: 1 Form A
2a: 2 Form A
1a
N
S
DC12
Terminals
Nil: Plug-in terminal type
S: Screw terminal type
SW: Screw terminal type
(wide pitch)
Q: NEMA terminal type
P: PC board terminal type*
V
Coil voltage
DC: 6, 12, 24, 48,
110 V
AC: 12, 24, 48,
120, 240 V
Pick-up voltage
N: 70% of nominal
voltage
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
* PC board terminal are available only for 1 Form A type of DC coil voltage.
UL/CSA, TÜV approved type is standard.
121
HE
4. Screw terminal type (wide pitch)
1a
51.0
2.008
47.6
1.874
40.0
1.575
14.4
.567
17.5
11.3
.689
.445
R4
M3.5
33.5
1.319
50.0
1.969
60
2.362
16.5
10.25
.650
.404
M3.5
mm
inch
2a
51.0
2.008
47.6
1.874
40.0
1.575
36.4
1.433
14.4
.567
11.3 17.5
.445 .689
R4
33.5
1.319
50.0
1.969
60
2.362
16.5
10.25
.650
.404
Schematic
1a
1
4
1
2a
2
3
4
M4.5
4.5
.177
M4.0
4.5
.177
6
5
6
5
Panel cutout
2-4.5±0.1 dia.
2-.177±.004
7.5
.295
47.6±0.1
1.874±.004
7.5
.295
44.5
1.752
3.5
.138
0.8
.031
44.5
1.752
0.8
.031
General tolerance:
±
0.3
±
.012
5. PC board terminal type
38.0
1.496
33
1.299
Schematic (Bottom view)
PC board pattern (Copper-side view)
6-2 dia.
6-.079 dia.
32
1.259
1
36.3
1.429
0.5
.020
4
.157
4.7
.185
4
18.6
.732
6
5
8.4
.331
24
.945
4.7
.185
REFERENCE DATA
1 Form A Type
1. Maximum switching power
100
50
30
20
10
5
DC resistive
AC resistive
2. Life curve
1,000
No. of operations,
×10
4
500
3. Contact temperature rise (DC type)
Measured portion: Inside the coil
Contact current: 30 A
70
Temperature rise,
°C
60
20°C
50 40°C
40
30
20
10
60°C
Contact current, A
100
50
250 V AC resistive
30 V DC resistive
1
0.5
10
5
30
100
500 1,000
0
5
10
15
20
25
30
35
0
100
110
120
Contact voltage, V
Contact current, A
Coil applied voltage, %V
4. Ambient temperature characteristics
Sample: HE1aN-AC120V, 6 pcs.
30
Rate of
change, %
20
10
Drop-out
voltage
20 40
–10
–20
–30
60 80
Ambient
temperature,
°C
Pick-up
voltage
-
x
-
x
–50
–20
0
124
HE
2 Form A Type
1. Maximum switching power
100
Contact current, A
50
30
20
10
5
DC resistive
AC resistive
2. Life curve
1,000
No. of operations,
×10
4
500
3. Contact temperature rise (DC type)
Measured portion: Inside the coil
Contact current: 30 A
70
60
Temperature rise,
°C
20°C
50 40°C
60°C
40
30
20
100
50
250 V AC resistive
30 V DC resistive
1
0.5
10
5
10
30
100
500 1,000
Contact voltage, V
0
5
10
15 20
25
30
Contact current, A
35
0
100
110
120
Coil applied voltage, %V
4. Ambient temperature characteristics
Sample: HE2aN-AC120V, 6 pcs.
-
x
-
x
Rate of
change, %
Pick-up
20 voltage
10
Drop-out
voltage
–50
–20
0
20 40
–10
–20
–30
60 80
Ambient
temperature,
°C
MOUNTING METHOD
1. Plug-in terminal type
M4 screw
Washer
Faston No.250
2. Screw terminal type
M 4 screw
Washer
3. Allowable installation wiring size for
screw terminal types and terminal blocks
1a type
2a type
2.6 mm or 5.5 mm
2
2.0 mm or 3.5 mm
2
Due to the UP terminals, it is possible to
either directly connect the wires or use
crimped terminal
NOTES
1. The dust cover should not be removed
since doing so may alter the characteris-
tics.
2. Avoid use under severe environmental
conditions, such as high humidity, organic
gas or in dust, oily locations and locations
subjected to extremely frequent shock or
vibrations.
3. When mounting, use spring washers.
Optimum fastening torque ranges from 5
kg to 7 kg·cm
4.5 to 6 pounds·inch.
4. Firmly insert the receptacles so that
there is no slack or looseness. To remove
a receptacle, 2 to 4 kg of pulling strength
is required. Do not remove more than one
receptacle at one time.Always remove
one receptacle at a time and pull it straight
outwards.
5. Install the relay so that it lies in direction
A (up-down direction). (Pick-up voltage
and drop-out voltage values are those
when installed in direction A.)
6. When using the AC type, the operate
time due to the in-rush phase is 20 ms or
more. Therefore, it is necessary for you to
verify the characteristics for your actual
circuit. Moreover, the release time for the
NC side of the 2a1b type requires the
same verification.
7. When using the push-on blocks for the
screw terminal type, use crimped termi-
nals and tighten the screw-down termi-
nals to the torque’s listed below.
M4.5 screw
M4 screw
M3.5 screw
147 N-cm to 166.6 N-cm
(15 to 17 kg·cm)
117.6 N-cm to 137 N-cm
(12 to 14 kg·cm)
78.4 N-m to 98 N-cm
(8 to 10 kg·cm)
8. All AC240V types are rated for double
coil voltage, both AC 220V AC 240V.
For Cautions for Use, see Relay Technical Information (Page 11 to 39).