Uncommitted Switch (loop back or relay driver) . . . . . +5V to -100V
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1.
θ
JA
is measured with the component mounted on an evaluation PC board in free air.
Electrical Specifications
Unless Otherwise Specified, T
A
= 0°C to 70°C for the HC55183, 184 only, all others -40°C to 85°C, V
BL
= -24V,
V
BH
= -100V, -85V or -75V, V
CC
= +5V, AGND = BGND = 0V, loop current limit = 25mA. All AC Parameters are
specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to 3.4kHz. Protection
resistors = 0Ω. These parameters apply generically to each product offering.
TEST CONDITIONS
MIN
TYP
MAX
UNITS
PARAMETER
RINGING PARAMETERS
(Note 2)
VRS Input Impedance (Note 3)
Differential Ringing Gain
4-Wire to 2-Wire Ringing Off Isolation
2-Wire to 4-Wire Transmit Isolation
AC TRANSMISSION PARAMETERS
(Notes 5, 6)
Receive Input Impedance (Note 3)
Transmit Output Impedance (Note 3)
4-Wire Port Overload Level
2-Wire Port Overload Level
2-Wire Return Loss
THD = 1%
THD = 1%
f = 300Hz
f = 1kHz
f = 2.3kHz
f = 3.4kHz
Longitudinal Current Capability (Per Wire) (Note 3)
480
VRS to 2-Wire, R
LOAD
=
∞
(Note 4)
Active mode, referenced to VRS input.
Ringing mode referenced to the differential ringing
amplitude.
78
-
-
-
80
60
60
-
82
-
-
kΩ
V/V
dB
dB
160
-
3.1
3.1
-
-
-
-
20
10
-0.20
-6.22
-6.32
C-Message
Psophometric
-
-
-
-
-
-
3.5
3.5
26
32
21
17
-
-
0.0
-6.02
-6.02
16
-73.5
10
-79.5
-
1
-
-
-
-
-
-
-
-
+0.30
-5.82
-5.82
19
-71
13
-77
kΩ
Ω
V
PK
V
PK
dB
dB
dB
dB
mA
RMS
mA
RMS
dB
dB
dB
dBrnC
dBmp
dBrnC
dBmp
Test for False Detect
Test for False Detect, Low Power Standby
4-Wire to 2-Wire Insertion Loss
2-Wire to 4-Wire Insertion Loss
4-Wire to 4-Wire Insertion Loss
Idle Channel Noise 2-Wire
Idle Channel Noise 4-Wire
C-Message
Psophometric
4
HC55180, HC55181, HC55183, HC55184
Electrical Specifications
Unless Otherwise Specified, T
A
= 0°C to 70°C for the HC55183, 184 only, all others -40°C to 85°C, V
BL
= -24V,
V
BH
= -100V, -85V or -75V, V
CC
= +5V, AGND = BGND = 0V, loop current limit = 25mA. All AC Parameters are
specified at 600Ω 2-wire terminating impedance over the frequency band of 300Hz to 3.4kHz. Protection
resistors = 0Ω. These parameters apply generically to each product offering.
(Continued)
TEST CONDITIONS
MIN
TYP
MAX
UNITS
PARAMETER
DC PARAMETERS
(Note 6)
Loop Current Limit Programming Range (Note 5)
Loop Current During Low Power Standby
LOOP DETECTORS AND SUPERVISORY FUNCTIONS
Switch Hook Programming Range
Switch Hook Programming Accuracy
Dial Pulse Distortion
Ring Trip Comparator Threshold
Ring Trip Programming Current Accuracy
Ground Key Threshold
Thermal Alarm Output
LOGIC INPUTS (F0, F1, F2, E0, SWC, BSEL)
Input Low Voltage
Input High Voltage
Input Low Current
Input High Current
LOGIC OUTPUTS (DET, ALM)
Output Low Voltage
Output High Voltage
POWER SUPPLY REJECTION RATIO
V
CC
to 2-Wire
f = 300Hz
f = 1kHz
f = 3.4kHz
V
CC
to 4-Wire
f = 300Hz
f = 1kHz
f = 3.4kHz
V
BL
to 2-Wire
V
BL
to 4-Wire
V
BH
to 2-Wire
V
BH
to 4-Wire
NOTES:
I
OL
= 5mA
I
OH
= 100µA
V
IL
= 0.4V
V
IH
= 2.4V
Max Low Battery = -52V
Forward polarity only.
15
18
-
-
45
26
mA
mA
5
Assumes 1% external programming resistor
-
-
2.4
-
-
IC junction temperature
-
-
±2
1.0
2.7
-
12
175
15
± 10
-
3.0
± 10
-
-
mA
%
%
V
%
mA
°C
-
2.0
-20
-
-
-
-
-
0.8
-
-
5
V
V
µA
µA
-
2.4
-
-
0.4
-
V
V
-
-
-
-
-
-
-
-
-
-
-
40
35
28
45
43
33
30
35
33
40
45
-
-
-
-
-
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
300Hz
≤
f
≤
3.4kHz
300Hz
≤
f
≤
3.4kHz
300Hz
≤
f
≤
3.4kHz
300Hz
≤
f
≤
1kHz
1kHz
<
f
≤
3.4kHz
2. These parameters are specified at high battery operation. For the HC55180 the external supply is set to high battery voltage, for the HC55181,
HC55183 and HC55184, BSEL = 1.
3. These parameters are controlled via design or process parameters and are not directly tested. These parameters are characterized upon initial
design release and upon design changes which would affect these characteristics.
4. Differential Ringing Gain is measured with VRS = 0.795 V
RMS
for -100V devices, VRS = 0.663 V
RMS
for -85V devices and VRS = 0.575 V
RMS
for -75V devices.
5. These parameters are specified at low battery operation. For the HC55180, the external supply is set to low battery voltage, for the HC55181,
HC55183 and HC55184, BSEL = 0.
6. Forward Active and Reverse Active performance is guaranteed for the HC55180, HC55181 and HC55184 devices only. The HC55183 is
How to set the IP address and gateway of vxworks (host)? If the setting is successful, can I use the ping command under Windows to connect to the network of the running vxworks? Can it be pinged?...
Optical communication manufacturers, please take note! Good news! Lumentum is selling a batch of cost-effective optical communication module packaging and testing equipment.Due to the recent productio...
The program is based on 430g2553, using the key of xx7299 chip. I set P10 as the interrupt port, set it to falling edge interrupt and connect it to the key of xx2799. When a key is pressed, the key of...
MSP430 capacitive single-touch sensor design guide, this is the official application manual, very authoritative. [[i] This post was last edited by Xinhai Baby on 2011-10-12 09:35 [/i]]...
Chapter 1 Complex Number Solutions for Linear Circuits 1.1 Concepts of Power and Components 1.2 Complex Number Solutions for Constant Parameter Linear Circuits 1.3 First-Order RC Filters 1.4 Second-Or...
High efficiency and low standby power consumption are two major challenges in today's switching power supply design. Resonant topology or LLC topology is becoming increasingly popular because it ca...[Details]
At present, the development of wireless power supply technology for electric vehicles (EVs) is becoming more and more active. In 2012, Volvo of Sweden established Volvo Technology Japan in Tokyo as...[Details]
Automotive applications are particularly sensitive to EMI events, which are unavoidable in a noisy electrical environment consisting of a central battery, bundled wiring harnesses, various inductiv...[Details]
In order to highlight the concept of "energy saving and environmental protection" of intelligent buildings, solar street lights are designed for intelligent communities. The inclination and capacit...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
Although it is relatively easy to check the stability of a simple amplifier at lower frequencies, it may be much more difficult to evaluate the stability of a more complex circuit. This artic...[Details]
With the development and widespread application of computer technology, especially in the field of industrial control, computer communication is particularly important. Although serial communication g...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
LED guardrail lights use fluorescent tubes or LEDs as light sources and continuous guardrails as carriers to form an approximately linear guardrail light strip. This article mainly introduces...[Details]