EEWORLDEEWORLDEEWORLD

Part Number

Search

300E-3C-15.5

Description
MEDIUM BLOW ELECTRIC FUSE, 300A, 15500VAC, 80000A (IR), INLINE/HOLDER
CategoryCircuit protection    Circuit protection   
File Size379KB,5 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

300E-3C-15.5 Overview

MEDIUM BLOW ELECTRIC FUSE, 300A, 15500VAC, 80000A (IR), INLINE/HOLDER

300E-3C-15.5 Parametric

Parameter NameAttribute value
MakerLittelfuse
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsMEDIUM
body height479.43 mm
Body length or diameter247.05 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size247.05mm x 479.43mm
Rated breaking capacity80000 A
Rated current300 A
Rated voltage (AC)15500 V
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
E Rated Medium Voltage Fuses
Current Limiting
“E” Rated fuses have time current characteristics designed
to provide current limiting protection for power transformers,
potential transformers, power centers, feeder centers, and
unit sub stations. When properly applied, they can protect
against high and low value fault currents.
NEMA Standards for “E” rated medium voltage fuses require
that fuses rated 100E or less open within 300 seconds (5
minutes) when subjected to an RMS value of 200-240% of
the fuse’s continuous current rating; and fuses with an “E”
rating larger than 100E must open within 600 seconds (10
minutes) when subjected to an rms current of 220-240% of
the fuse’s continuous current rating. These values establish
one point on the time-current curve.
Application Note:
Since these fuses are used for the protection of general
purpose circuits which may contain transformers, motors,
and other equipment producing inrush and/or overload cur-
rents, fuses should generally be rated at 140% of the normal
full load current, and circuits should be analyzed to ensure
that system load currents will not exceed the current rating
of the fuse.
CHARACTERISTICS
Voltage Rating:
2,400 volts – 38,000 volts
Current Range:
10E – 600E
OPTIONS
I
I
Hermetically Sealed for use in hazardous locations
(add “S” suffix to part number)
Clip-lock (CL) and bolt-in styles available.
3"DIA
6.38"
9.75"
Dim.A
(Clip
Center)
Dim.B
FIGURE 14
FIGURE 15
FIGURE 16
E
RATED
Catalog
Number
10E-1C-2.75
15E-1C-2.75
20E-1C-2.75
25E-1C-2.75
30E-1C-2.75
40E-1C-2.75
50E-1C-2.75
65E-1C-2.75
80E-1C-2.75
100E-1C-2.75
125E-1C-2.75
150E-1C-2.75
200E-1C-2.75
125E-2C-2.75
150E-2C-2.75
175E-2C-2.75
200E-2C-2.75
225E-2C-2.75
250E-2C-2.75
300E-2C-2.75
350E-2C-2.75
400E-2C-2.75
450E-2C-2.75
Old
Catalog
Number
LCX 10E
LCX 30E
LCX 40E
LCX 50E
LCX 65E
LCX 80E
LCX 100E
LCX 125E
LCX 150E
LCX 175E
LCX 200E
LCX 250E
LCX 300E
LCX 400E
Size
10E
15E
20E
25E
30E
40E
50E
65E
80E
100E
125E
150E
200E
125E
150E
175E
200E
225E
250E
300E
350E
400E
450E
Dim. A
(inches)
Dim. B
(inches)
Max
Interrupting
Rating
RMS (Asym)
7"
10.875"
80,000
7"
10.875"
80,000
Figure
Number
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
2.75 Max. KV
67
Comparison and analysis of four types of logical analysis, Hantai 6022, ZLG100M, pirated SALEAE, Mengyuan
1: Pirated SALEAE, priced at 30 yuan, bought from Taobao. Although it is cheap, it can be used. Of course, it cannot measure high frequencies. And don't underestimate this 30 yuan small machine, it wi...
long521 Test/Measurement
[Casual Chat] Some questions about LCD screens
I feel like this post is not suitable for anywhere else, so I'll put it here for now. There are so many experts on the forum, so I'm here to ask. I have a question for everyone: How do I know the pin ...
风的世界 TI Technology Forum
I am a beginner in ARM and I want to make a car safety system. Please give me some suggestions
I am a beginner in ARM and I am not sure what I am learning. I am a junior in college, majoring in electronics. I was confused in my first and second years. I didn't learn anything. I was also careles...
chrislu ARM Technology
Design and implementation of preamplifier in mobile medical service system
[size=3][color=#000080]All kinds of biological signals are low-frequency weak natural signals. In order to detect weak biological signals covered by background noise with high precision and high speed...
voyage620 Medical Electronics
Five skills required for RF test engineers
Five skills required for RF test engineers RF Test Engineers are an integral part of every manufacturing environment as well as the development team of advanced RF products and projects.Some people sa...
len123 Test/Measurement
[MSP430 compiler usage experience] Install and green IAR in Windows 7
[align=left][size=5]Introduce how to install IAR in WIN7 system and correctly green the software [/size][/align][align=left]All software installations must be installed as an administrator by right cl...
眼大5子 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2424  162  988  1727  1968  49  4  20  35  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号