0215.160HX Overview

Electric Fuse

0215.160HX Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
Circuit protection typeELECTRIC FUSE
Manufacturer's serial number0215
Base Number Matches1
Axial Lead & Cartridge Fuses
5×20 mm > Time-Lag > 215 Series
215 Series, 5×20 mm, Time-Lag (Slo-Blo
®
) Fuse
Description
PS
E
5×20mm Time-Lag surge withstand ceramic body cartridge
fuse designed to IEC specification
Features
• Designed to International
(IEC ) Standards for use
globally
• High breaking capacity
Applications
Ampere Range
• Meet the IEC 60127-2,
Sheet 5 specification for
Time-Lag fuses
• RoHS compliant and
lead-free
Agency Approvals
Agency
Agency File Number
PS
E
Cartridge Certificates:
NBK080205-E10480A
NBK250702-E10480E
NBK100408-JP1021A
Leaded Certificates:
NBK080205-E10480B
NBK250702-E10480F
NBK100408-JP1021B
.
Certificates:
2005010207145714
Certificates:
SU05001– 2011
SU05001– 2012
Recognised File:
E10480
File:
029862
Acc. Class:
LR1422 – 30
License:
1112132
902193
1117976
1200154
1200155
License:
40013521
License:
40016610
License:
KM41462
Certificate:
CQC07012021808
Certificate:
J50258578
1A – 5A
6.3A – 15A
16A – 20A
1A – 5A
6.3A – 15A
16A – 20A
1A – 6.3A
1A – 3.15A
4A – 10A
125mA – 20A
Used as supplementary protection in appliance or
utilization equipment to provide individual protection for
components or internal circuits.
Additional Information
Datasheet
Resources
Samples
Electrical Characteristics for Series
% of Ampere
Rating
Ampere Rating
125mA – 800mA
150%
1A – 3.15A
4A – 6.3A
8A – 20A
Opening Time
60 minutes, Minimum
60 minutes, Minimum
60 minutes, Minimum
30 minutes, Minimum
30 minutes, Maximum
30 minutes, Maximum
30 minutes, Maximum
30 minutes, Maximum
.25 sec. Min.; 80 secs. Max.
.75 sec. Min.; 80 secs. Max.
.75 sec. Min.; 80 secs. Max.
.75 sec. Min.; 80 secs. Max.
.05 sec., Min.; 5 secs. Max.
.095 sec., Min.; 5 secs. Max.
.150 sec., Min.; 5 secs. Max.
.150 sec., Min.; 5 secs. Max.
.005 sec., Min.; .150 sec. Max.
.010 sec., Min.; .150 sec. Max.
.010 sec., Min.; .150 sec. Max.
.010 sec., Min.; .150 sec. Max.
500mA – 12A
125mA, 160mA
200mA – 800mA, 8A, 10A
1A - 6.3A
12A
*15A – *20A
200mA – 8A
*10A
*12A
200mA – 10A
8A – 10A
16A/20A
125mA – 20A
125mA – 800mA
210%
1A – 3.15A
4A – 6.3A
8A – 12A
125mA – 800mA
275%
1A – 3.15A
4A – 6.3A
8A – 20A
125mA – 800mA
400%
1A – 3.15A
4A – 6.3A
8A – 20A
125mA – 800mA
1000%
1A – 3.15A
4A – 6.3A
8A – 20A
* Approved for cartridge versions only
© 2014 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 06/13/14
Lonely man - Yiyeqiu
It's a lonely winter The midnight wind smiles cunningly Deliberately tearing off my thin clothes I played with my messy hair On the poor street Playing a lonely role Frustrated Cigarette Wandering in ...
david Talking
I want to build a data access platform for NB-IOT devices based on the COAP protocol. In addition to LIBCOAP, what other technologies are used?
I want to build a data access platform for NB-IOT devices based on the COAP protocol. In addition to LIBCOAP, what other technologies are used?...
三亚东北人 stm32/stm8
What are the differences between the register settings of CC2530 and CC2430? There seems to be no detailed information on 2530.
Recently I found that the clock register CLKCON of 2530 is somewhat different from that of 2430. The program encountered problems, and I don’t know how many registers are inconsistent with 2430....
panxm916 RF/Wirelessly
Solenoid control
Have you ever made two electromagnets to control the swing? Can you give me some advice? What signal can make the swing stable? What I see on the oscilloscope seems to be a square wave, but it also ha...
古木寒 Embedded System
What are the mainstream sliding fingerprint sensors now? Which ones are easy to use and well supported?
I was planning to use aes2510, but a small company needs 100 or 80 people a month, and they may not bother to sign... I'm speechless... Is there anything similar that's good? Please recommend it to me...
wukaihongxyz Embedded System
A detailed comparison of the advantages and disadvantages of DLP and PDP
After more than ten years of development, the system has been widely used in various fields. However, due to the certain technical difficulty and high technical content of large-screen splicing produc...
meiping520 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 831  2671  1173  1215  2016  17  54  24  25  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号