Electrical Specifications @ 25°C — Operating Temperature -40°C to 125°C
TRANSFORMERS
Part
3,4
Number
Application
2
Turns Ratio
Pri.
Sec.
Pri. Aux.
Primary
Secondary
Isolation
Primary
Inductance
(µH MIN)
Leakage
Inductance
(µH MAX)
DCR
(mΩ MAX)
Pri.
Pri.
Aux.
Sec.
A
Sec.
B
ER9.5 - 8 P
IN
SMT - (12.1
MM X
10.7
MM X
6.6
MM
MAX)
PB2090
2.4W Flyback Transformer
Vin=36-72v, Freq.=200kHz
Vout=12v/0.2A, 12v/.05mA
1.25W Flyback Transformer
Vin=18-36v, Freq.=200kHz
Vout=5v/0.25A, 12v/50mA
2.4W Flyback Transformer
Vin=18-36v, Freq.=200kHz
Vout=12v/0.2A, 12v/50mA
.5W Flyback Transformer
Vin=20-30v, Freq.=200kHz
Vout=±5v/50mA
2.6W Flyback Transformer
Vin=4.5-5.5v, Freq.=200kHz
Vout=±5v/0.5A, 6v/0.02mA
1
0.33
0.330
1500Vdc
Operational
1500Vdc
Operational
1500Vdc
Operational
1000Vac
Operational
1500Vdc
Operational
132
@ 0.41A
62
@ 0.52A
32
@ 0.8A
814
@ 0.8A
5
700
820
185
N/A
PB2109
1
0.714
0.287
3
350
650
50
N/A
PB2110
1
0.68
0.680
2
180
820
185
N/A
PB2135
1
0.42
0.42
1.11 (5v)
1.33 (6v)
N/A
11
5772
N/A
364
364
PA0663
1
N/A
4.6
0.15
100
N/A
97
73
ER11 - 10 P
IN
SMT - (12.7
MM X
11.4
MM X
6.6
MM
MAX)
PA1032
5W Flyback Transformer
Vin=30-57v, Freq.=250kHz
Vout=3.3v/1.5A, 10v/15mA
6W Flyback Transformer
Vin=18-36v, Freq.=200kHz
Vout=±12v/0.25A, 12v/20mA
1
0.166
0.500
1500Vdc
Operational
500Vdc
Operational
46.6
1.65
380
250
15
N/A
PB2162
1
0.393
0.393
85
@ 0.8A
2.5
490
1100
298
298
ER14.5 - 10 P
IN
SMT - (16.5
MM X
15.5
MM X
7.6
MM
MAX)
PA1006
7.5W Flyback Transformer
Vin=36-65v, Freq.=250kHz
Vout=5.0v/1.5A, 15v/30mA
7.5W Flyback Transformer
Vin=36-65v, Freq.=250kHz
Vout=3.3v/2.25A, 16v/30mA
8.5W Flyback Transformer
Vin=36-65v, Freq.=250kHz
Vout=3.3v/2.57A, 8v/20mA
1
0.154
0.462
1500Vdc
Operational
1500Vdc
Operational
1500Vdc
Operational
152
5
670
750
21
N/A
PA1026
1
0.115
0.500
152
5
670
830
10
N/A
PA1085
1
0.115
0.269
152
5
670
450
10
N/A
USA 858 674 8100
•
UK 44 1483 401 700
•
France 33 3 84 35 04 04
•
Singapore 65 6287 8998
•
Shanghai
86 21 54643211 / 2
•
China 86 769 85538070
•
Taiwan 886 3 4641811
www.pulseeng.com
1
P625.B (3/06)
HIGH FREQUENCY CONVENTIONAL
WOUND MAGNETICS
ER Platforms - ER9.5, ER11 and ER14.5
NOTES :
1. The temperature of the component (ambient plus temperature 3. Add 'T' suffix to the part number for Tape & Reel version
rise) must be within the stated operating temperature range.
(ie: PA1032T).
2. The above transformers and inductors have been tested 4. RoHS compliant parts are being introduced. Please contact Pulse
and approved by Pulse's power IC partners and are sited in the
for RoHS compliant part availability. If available, order part by
appropriate datasheet or evaluation board documentation at these
adding the suffix "NL" to the part number (i.e. PA1032 becomes
PA1032NL and PA1032T becomes PA1032NLT).
companies. To determine which IC and IC partners are matched
with the above Pulse part numbers please consult the IC Cross
Reference on the Pulse website.
Mechanical
ER9.5
8
.475
12,07
MAX
8X
.027
0,79
5
8X
.063
1,60
6X
4
8X
.079
6X
2,00
.063
1,60
.079
2,00
Part Number
Date Code
Country of Origin
1
(.237)
(6,00)
.398
10,11
SUGGESTED PAD LAYOUT
.323
8,20 MAX
.420
10,67 MAX
.260
6,60
MAX
.010
0,25
.006/0,15
8 SURFACES
(.392)
(9,96) MAX
ER11
10
.450
MAX
11,43
6
.500
12,70
MAX
10X
.063
1,60
(.366)
(9,30)
Date Code - Country of Origin
Part Number
1
8X
.079
2,00
(.315)
(8,00)
5
.063
10X
1,60
8X
.395
10,03
.079
2,00
SUGGESTED PAD LAYOUT
.260
6,60
MAX
10X
.028
0,71
.024
0,61
.006/0,15
.010
10 SURFACES
0,25
USA 858 674 8100
•
UK 44 1483 401 700
•
France 33 3 84 35 04 04
•
Singapore 65 6287 8998
•
Shanghai
86 21 54643211 / 2
•
China 86 769 85538070
•
Taiwan 886 3 4641811
www.pulseeng.com
2
P625.B (3/06)
HIGH FREQUENCY CONVENTIONAL
WOUND MAGNETICS
ER Platforms - ER9.5, ER11 and ER14.5
ER14.5
6
10
.063
1,60
Mechanical
Date Code - Country of Origin
Part Number
.650
15,50
MAX
10X
5
(.392)
(9,96)
.610
MAX
15,50
1
.098
8X
2,50
.063
10X
1,60
8X
.575
14,XX
.098
2,50
SUGGESTED PAD LAYOUT
(.476)
(12,09)
.300
7,62
MAX
.012
0,30
.006/0,15
10 SURFACES
10X
.028
0,71
(.575)
(14,60)
Schematics
ER9.5
1,2
4.5-5.5V
PA0663
6V, .02V
PB2090
PB2110
5
6
7
5V, 0.5A
4
36-72V
200kHz
5
12V, 0.20A
4
18-36V
200kHz
5
12V, 0.20A
4,3
Sec2 should be stacked on top of
Sec1 to achieve desired output
8
3
2
12V, 0.05A
8
3
2
12V, 0.05A
8
1
PB2135
1
6
+5V, 0.05A
PB2109
4
18-36V
200kHz
5
5V, 0.25A
4
3
2
1
3
2
12V, 0.05A
8
20-30V
200kHz
5
8
-5V, 0.05A
1
7
Connect pins 2 and 3 on PCB
to complete Primary
USA 858 674 8100
•
UK 44 1483 401 700
•
France 33 3 84 35 04 04
•
Singapore 65 6287 8998
•
Shanghai
86 21 54643211 / 2
•
China 86 769 85538070
•
Taiwan 886 3 4641811
www.pulseeng.com
3
P625.B (3/06)
HIGH FREQUENCY CONVENTIONAL
WOUND MAGNETICS
ER Platforms - ER9.5, ER11 and ER14.5
Schematics
ER11
PA1032
PB2162
3
30-57V
250kHz
7
3.3V, 1.5A
5
18-36V
200kHz
7
4
+12V, 0.25A
1
4
10V, 0.015A
9
3
2
12V, 20mA
8
9
-12V, 0.25A
5
1
10
ER14.5
PA1006
PA1026
PA1085
4
36-65V
250kHz
9
5V, 1.5A
4
36-65V
250kHz
9
3.3V, 2.25A
4
36-72V
200kHz
9
3.3V, 2.57A
3
2
16V, 0.03A
7
3
2
16V, 0.03A
7
3
2
8V, 0.02A
7
1
1
1
For More Information:
Pulse Worldwide
Headquarters
Pulse
Northern Europe
Pulse
Southern Europe
Zone Industrielle
F-39270
Orgelet
France
TEL: 33 3 84 35 04 04
FAX: 33 3 84 25 46 41
Pulse
Pulse North China
China Headquarters
Room 1503
No. 1
Industrial District
Changan, Dongguan
China
TEL: 86 769 85538070
FAX: 86 769 85538870
XinYin Building
No. 888 YiShan Road
Shanghai 200233
China
TEL: 86 21 54643211/2
FAX: 86 21 54643210
Pulse South Asia
150 Kampong Ampat
#07-01/02
KA Centre
Singapore 368324
TEL: 65 6287 8998
FAX: 65 6280 0080
Pulse North Asia
No. 26
Kao Ching Road
Yang Mei Chen
Taoyuan Hsien
Taiwan, R. O. C.
TEL: 886 3 4641811
FAX: 886 3 4641911
12220 World Trade Drive 3 Huxley Road
Surrey Research Park
San Diego, CA 92128
Guildford, Surrey GU2 5RE
U.S.A.
United Kingdom
www.pulseeng.com
TEL: 44 1483 401700
TEL: 858 674 8100
FAX: 44 1483 401701
FAX: 858 674 8262
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product
names mentioned herein may be trademarks or registered trademarks of their respective owners.
How does LPC11c14 use the interrupt identifier INTID to read the message number? After receiving CAN, won't a status interrupt be generated first? Then won't the message interrupt number never be reac...
I have an EPSON R310 inkjet printer. A while ago, the F1 and C5888 tubes were burned out due to cleaning the print head. After replacing them, the computer prompts that the new hardware model is EPSON...
It is like this, there is a reader with a gpio interface, it has 10 interfaces, and I want to use this thing to control a three-color alarm light (three colors, and an alarm). How do I wire this thing...
I have written a piece of code that can input data to the current focus: INPUT Input; for( i=0 ; strInfo[i]!='\0' ; i++ )//strInfo has been set{ Input.type =INPUT_KEYBOARD; Input.ki.wVk =strInfo[i]; S...