High Performance Beta Range
RoHS
Pb
Greentube™ SL1002A Series Gas Plasma Arrester
®
The Broadband Optimized™ SL1002 series has been especially
developed for use in broadband equipment. Unique design
features offer high levels of performance on fast rising transients
in the domain of 100V/µS to 1KV/µS, which are those most likely
from induced Lightning disturbances. These devices have Ultra
low capacitance (typically 1.2pF or less) and present insignificant
signal losses up to 1.5GHz. These devices are extremely robust
and are able to divert a 5000A pulse without destruction. For AC
Power Cross of long duration, overcurrent protection is
recommended.
FEATURES
•
RoHS
compliant and
Lead-free
• Ultra Low Insertion Loss
•
Surface mountable
•
5KA surge capability tested with 8/20µS pulse
as defined by IEC 61000-4-5
•
Excellent response to fast rising transients.
•
Can be used to meet Telcordia GR1089
3.5
4.2±0.2
without series resistance
•
10/700 6KV capability, as per ITUT k.21, enhanced test level
•
2000 Amp 2/10µS surge rating
•
Meets FCC part 68 10/160µs waveform, 200A test and
5.0
6.0 ±0.2
10/560µs waveform 100A test.
Applications:
•
Broadband equipment.
•
ADSL equipment.
•
XDSL equipment.
•
Satellite and CATV equipment.
•
General telecom equipment.
1.3
RECOMMENDED PAD LAYOUT
0.8
SL1002AxxxC
4.3±0.3
6.2 ±0.2
GDT SHOWING SEATING PLANE
FOR SL1002AxxxSM
SL1002AxxxSM
6.2 ±0.2
SL1002AxxxSM
All dimensions in mm
Mechanical Specifications:
Weight:
Materials:
0.63g (0.022 oz.)
Electrode Base: Nickel Iron Alloy
Electrode Plating: Bright Sn
Body: Ceramic
‘LF’ logo, Voltage and date code
Device Marking:
325
w w w. l i t t e l f u s e . c o m
High Performance Beta Range
RoHS
Pb
Greentube™ SL1002A Series Gas Plasma Arrester
®
LITTELFUSE 2 TERMINAL MINI ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
DC Breakover
Voltage @100 V/s
Volts
Part
Number*
SL1002A090
SL1002A230
SL1002A250
SL1002A260
SL1002A350
SL1002A600
MIN
70
184
200
210
280
480
MAX
120
276
300
310
420
720
MAX Dynamic
Breakover
Voltage
1
100 V/µs
Volts
360
400
400
400
500
800
1kV/µs
Volts
700
500
500
500
600
900
AC
Discharge
Current
2
Amps
5
5
5
5
5
5
Max
Repetitive
Impulse
Current
3
kAmps
5
5
5
5
5
5
MAX Single
Impulse Current
2/10
µs
kAmps
2
2
2
2
2
2
2/350
µs
kAmps
2
2
2
2
2
2
Max
Leakage
Current
4
nAmps
100
100
100
100
100
100
Nominal
On-state
Voltage
@1A
Volts
20
20
20
20
20
20
Holdover
Voltage
5
Volts
50
135
135
135
135
135
*Max capacitance is 1.2 pF,
measured at 1 MHz, zero volt bias
Notes:
1.
2.
3.
4.
5.
Comparable to the silicon measurement Switching Voltage (Vs)
10 shots, AC 60Hz, 1µs duration
10 shots, 8/20µs waveform per IEC 61000-4-5
Measured at 100V, except 90VDC devices wich are measured at 50V
Tested according to ITU-T Rec. K.12
8
GAS DISCHARGE
Voltage vs Time Characteristic
Max dynamic breakover
voltage
Typical Insertion Loss
@ 1.0 GHz = 0.01 dB
@1.4GHz = 0.1dB
@1.8 GHz = 0.53 dB
@2.1 GHz = 0.81 dB
@2.45 GHz= 1dB
@2.8 GHz = 1.2 dB
@3.1 GHz = 1.5dB
Voltage
(V)
Hold-over voltage
@3.5 GHz = 2.1 dB
On-State voltage
0
200
400
600
Time (ns)
800
1000
1200
w w w. l i t t e l f u s e . c o m