EEWORLDEEWORLDEEWORLD

Part Number

Search

BRX48

Description
SILICON CONTROLLED RECTIFIER,300V V(DRM),800MA I(T),TO-226AB
CategoryAnalog mixed-signal IC    Trigger device   
File Size128KB,2 Pages
ManufacturerNXP
Websitehttps://www.nxp.com
Download Datasheet Parametric View All

BRX48 Overview

SILICON CONTROLLED RECTIFIER,300V V(DRM),800MA I(T),TO-226AB

BRX48 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
package instruction,
Reach Compliance Codeunknown
Nominal circuit commutation break time8 µs
Maximum DC gate trigger current0.2 mA
Maximum DC gate trigger voltage0.9 V
Maximum holding current5 mA
JESD-609 codee0
Maximum leakage current0.0001 mA
On-state non-repetitive peak current6 A
Maximum on-state voltage1.7 V
Maximum on-state current800 A
Maximum operating temperature125 °C
Minimum operating temperature-45 °C
Off-state repetitive peak voltage300 V
surface mountNO
Terminal surfaceTin/Lead (Sn/Pb)
Trigger device typeSCR
Base Number Matches1
Does anyone have the s3c2410 (arm9) schematic and PCB diagram?
Does anyone have the s3c2410 (arm9) schematic and PCB diagram?...
mondayfriday ARM Technology
In good health
[font=黑体][size=5]Life is just a few decades long, not long, not short either. [/size][/font] [font=黑体][size=5]Good health and happiness are more important than anything else. [/size][/font] [font=黑体][...
RCSN Talking
What is synchronous logic and asynchronous logic?
The wired-and logic is a function that can be realized by connecting two output signals. In hardware, it is realized by using OC gates. If OC gates are not used, the current may be too large and burn ...
2122516396 FPGA/CPLD
This morning at 10:00, [Prize-winning live broadcast: TI's story - IC Genesis]
[align=center][url=https://www.eeworld.com.cn/ads/clickads.php?id=13404][size=6]>>Live Streaming Entrance[/size][/url][/align] [size=5] [/size] [size=5]Live Streaming Time: October 25 (this morning) 1...
EEWORLD社区 TI Technology Forum
Have you ever tried RS485 to RS485 bidirectional transmission?
The host computer needs to communicate with the RTU module through the meter header, which requires transparent transmission of the meter header. The hardware interface between the devices is RS485, a...
dzgcsj_yrj DIY/Open Source Hardware
Research on common application circuits of diodes and their troubleshooting methods
[i=s]This post was last edited by qwqwqw2088 on 2018-1-24 08:33[/i] [size=4]1. Diode rectifier circuit and fault handling The forward conduction and reverse cutoff characteristics of the diode can be ...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1254  2663  1935  1158  1632  26  54  39  24  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号