High power-density, an industrial temperature range of -40°C to +85°C and extra features
like Remote-On-Off- control are just some of the characteristics of this converter, ideal for
highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV
by choosing option "/H2" or "/H3" in which case it is also ideal for medical applications which
additionally require EN-60601-1 certification.
Selection Guide
5V, 12V, 24V and 48V Input Types
Part Number
Input
Rated Output Output Current
Voltage Range
Voltage
at Full Load
SIP8
(VDC)
(VDC)
(mA)
RS-xx3.3S (H2/H3)
4.5-9, 9-18
3.3
500
18-36, 36-72
RS-xx05S (H2/H3)
4.5-9, 9-18
5
400
18-36, 36-72
RS-xx09S (H2/H3)
4.5-9, 9-18
9
222
18-36, 36-72
RS-xx12S (H2/H3)
4.5-9, 9-18
12
166
18-36, 36-72
RS-xx15S (H2/H3)
4.5-9, 9-18
15
134
18-36, 36-72
RS-xx3.3D (H2/H3)
4.5-9, 9-18
±3.3
±250
18-36, 36-72
RS-xx05D (H2/H3)
4.5-9, 9-18
±5
±200
18-36, 36-72
RS-xx09D (H2/H3)
4.5-9, 9-18
±9
±111
18-36, 36-72
RS-xx12D (H2/H3)
4.5-9, 9-18
±12
±83
18-36, 36-72
RS-xx15D (H2/H3)
4.5-9, 9-18
±15
±67
18-36, 36-72
RS-xx3.3SZ (H2/H3)
9-36
3.3
500
18-72
RS-xx05SZ (H2/H3)
9-36
5
400
18-72
RS-xx09SZ (H2/H3)
9-36
9
222
18-72
RS-xx12SZ (H2/H3)
9-36
12
166
18-72
RS-xx15SZ (H2/H3)
9-36
15
134
18-72
RS-xx3.3DZ (H2/H3)
9-36
±3.3
±250
18-72
RS-xx05DZ (H2/H3)
9-36
±5
±200
18-72
RS-xx09DZ (H2/H3)
9-36
±9
±111
18-72
RS-xx12DZ (H2/H3)
9-36
±12
±83
18-72
RS-xx15DZ (H2/H3)
9-36
±15
±67
18-72
Efficiency
typ.
(%)
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
75
75
80
80
80
80
83
83
84
84
73
73
77
77
80
80
81
81
83
83
Max
Capacitive
Load
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
100
2 Watt
SIP8 Isolated
Single
&
Dual
Output
2011/65/EU
6/6
RoHS
E-224736
UL-60950-1 Certified
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix)
RS
Derating-Graph
(Ambient Temperature)
RS-S(Z)_D(Z)
Output Power (%)
80
60
40
30
20
0
4:1
2:1
Safe Operating Area
-40
0
50 75 100
85
Operating Temperature °C
150
No suffix is standard isolation (1kVDC) e.g, RS-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3
E-126
REV: 2/2017
2:1 Input
(RS-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(RS-SZ/DZ)
xx = 9-36Vin = 24
xx = 18-72Vin = 48
www.recom-power.com
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Accuracy
Line Voltage Regulation
Load Voltage Regulation
Minimum Load
Output Ripple and Noise (20MHz limited)
Switching Frequency
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
Full Load
RS-05xxS_D
RS-12xxS_D
RS-24xxS_D, SZ_DZ
RS-48xxS_D, SZ_DZ
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
20%-100% Load
RS-S_D(Z)
Series
2:1 and 4:1
±2% typ.
±0.5% max.
±0.5% max.
10%
(2)
50mVp-p max.
100kHz min. / 300kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max
1GΩ min.
2:1
4:1
Continuous
–40°C to +85°C
–40°C to +75°C
–55°C to +125°C
95% RH
4.7g
22 pcs per Tube
using MIL-HDBK 217F
using MIL-HDBK 217F
Report: SPCLVD1605077-10
Report: MDD1205098-3 + RM1205098-3
Report: E224736-A35
1398 x 10
3
hours
210 x 10
3
hours
EN60950-1, AM2:2013
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Specifications
(measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
(No Derating)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
Certifications
EN General Safety
EN Medical Safety
UL General Safety
RS
}
Detailed Information see
Application Notes chapter "MTBF"
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1:
Note 2:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-power.com
REV: 2/2017
E-127
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency / Load
100
80
60
40
RS-S_D(Z)
Series
RS-05xx types
2
1.70
1.5
RS-24xx
2412
Output Power (W)
2405
2415
2409
Efficiency %
1
0.5
0
20
0
0%
20%
40%
60%
80%
100%
4.5 5
6
7
8
9
Total Output current (%)
Input Voltage (V)
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
Single Output
Dual Output
11.10
4.1
RECOM
RS-xxxxS_D
****
0.50±0.05
RECOM
RS-xxxxS
****
1 2 3
5 6 7 8
RECOM
RS-xxxxD
****
1 2 3
5 6 7 8
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Recommended Footprint Details
2.54
1.0ø+0.15/0
Pin #
1
2
3
5
6
7
8
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
21.80
0.25
Bottom View
3.20
2.0
2.54
Top View
RS
NC = No Connection
NC* = NC, but no external Connection allowed.
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON.
There is no allowed low state for this pin.
Application Examples
ON/OFF CONTROL
V+
+Vin
V
IN
+
ON
OFF
V
IN
-
LEAVE OPEN
CTRL
+Vout
3
5~12
-Vin
1N4148
68
Ω
CTRL
-Vout
10K
FET.
V-
I
= 3V
O = 0.5V or GND
Remote ON/OFF
ON: open or high impendance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
Please help me to explain the specific functions of this circuit; what are the uses of D1 and D2? What is the use of switch S and what happens when the switch is pressed? What components are needed to...
When the computer is connected to the Internet via a mobile phone, how can I switch from GPRS mode to AT command mode while maintaining GPRS connection?...
As the title says: When should the left and right channels be connected to one audio signal, and when should the two channels be connected separately? Thank you for your advice, I'd appreciate it!...
[:(]I have to submit my graduation thesis soon. Can any expert help me explain this circuit diagram? It would be best if it can be more detailed. Thank you in advance. [ip]...
A vacuum eutectic furnace is a critical piece of equipment used in the manufacturing and processing of various materials, particularly in the fields of microelectronics and nanotechnology. One of t...[Details]
The structure of an LCD TV primarily consists of the LCD display module, power module, driver module (primarily including the main driver board and tuner board), and keypad module. LCD display modu...[Details]
For healthcare professionals, accurate diagnosis and treatment are crucial for a clear picture of a person's health. However, healthcare professionals often rely on tests at medical facilities, cli...[Details]
Definition of interactive projection system:
Interactive projection systems, also known as multimedia interactive projection, are available in floor, wall, and tabletop interactive projection....[Details]
Gross profit margin jumped from 13.6% in the first half of last year to 25.9%, almost doubling year-on-year.
On August 21, RoboSense released its interim performance report, in which the...[Details]
Robotics
has become
LiDAR
's "second growth curve."
While LiDAR was still battling with its "pure vision" rivals in the automotive field, another field ignited the demand f...[Details]
On August 21, WeRide officially launched WePilot AiDrive, a one-stage end-to-end assisted driving solution developed in cooperation with Bosch. This comes only half a year after the two parties' "t...[Details]
On August 22, South Korean media Nate reported on the 20th local time that Samsung Electronics is introducing Hyper Cell technology into its most advanced 2nm process technology, striving to improv...[Details]
The all-new MG4 was recently officially announced on the Ministry of Industry and Information Technology's (MIIT) new vehicle announcement. The all-new MG4's semi-solid-state battery version addres...[Details]
According to foreign media reports, Nissan Motor has recently reached a cooperation with US battery technology company LiCAP Technologies to jointly promote the research and development of next-gen...[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
Smartphones have become essential digital devices, and the growing number of smartphone-centric applications is enriching people's lives. As users, they desire a better app experience and a wider r...[Details]
PowiGaN achieves 95% efficiency at both light and full loads, meeting critical operational and safety requirements.
DARWIN, Australia and SAN JOSE, Calif.,
August 22, 2025 – Powe...[Details]
Recently, Joyson Electronics has made positive progress in the core technology research and development of the robot's "brain and brain" and key components, and launched the industry's first integr...[Details]
On August 21st, BYD announced the launch of its next-generation "Little White Pile" product, the "Lingchong"
charging
pile
, which is now available for general sale. This charging pile feat...[Details]