HQCD-090-03.75-SED-STR-2

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size2MB,8 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

HQCD-090-03.75-SED-STR-2 Overview

Interconnection Device, ROHS COMPLIANT

HQCD-090-03.75-SED-STR-2 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
REVISION U
VERTICAL
(HQCD-060-XX.XX-STR-STR-1 SHOWN)
FIG. 1
HQCD-XXX-XX.XX-XXX-XXX-X-X
No OF POSITIONS
-030, -060, -090, -120
(PER ROW)
LENGTH
-XX.XX (INCHES)
(03.75[95.3] MIN)
(SEE NOTE 2)
(SEE NOTE 8)
FIRST END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 2)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
-TPU: TERMINAL, PANEL MOUNT, UP
-TPD: TERMINAL, PANEL MOUNT, DOWN
-SPU: SOCKET, PANEL MOUNT, UP
-SPD: SOCKET, PANEL MOUNT, DOWN
(SEE TABLE 11 & SHEET 6)
(ONLY AVAILABLE ON -030,-060, AND -090)
END OPTION
-F: SCREW OPTION FIRST END ONLY (NOT AVAILABLE
WITH XPX OPTIONS)
-S: SCREW OPTION SECOND END ONLY
-B: SCREW OPTION BOTH ENDS (NOT AVAILABLE
WITH XPX OPTIONS)
-N: NO CAPS
-L: FIRST END RT1 OPTION (SEE NOTES 9 & 10)
-R: SECOND END RT1 OPTION (SEE NOTES 9 & 10)
-D: BOTH ENDS RT1 OPTION (SEE NOTES 9 & 10)
-1: FIRST END SCREW OPTION,
SECOND END RT1 OPTION (SEE NOTES 9 & 10)
-2: FIRST END RT1 OPTION,
SECOND END SCREW OPTION (SEE NOTES 9 & 10)
(SEE FIG. 3, SHEET 5 FOR EDGE MOUNT
END OPTIONS)
(SEE FIG. 4, SHEET 5 FOR DOUBLE
VERTICAL END OPTIONS)
(SEE FIG. 5, SHEET 5 FOR NO CAPS)
(LEAVE BLANK FOR STANDARD CAPS
BOTH ENDS)
WIRING OPTION
-1: PIN 1 TO PIN 1
-2: PIN 1 TO PIN 2
-3: PIN 1 TO PIN N-1
-4: PIN 1 TO PIN N
(SEE TABLE 9, SHEET 6)
SECOND END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 3)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
DO NOT
SCALE FROM
THIS PRINT
SUB-HQCD-X-XXX-XX-XX
01
LENGTH: XX.XX + "L" REF (SEE TABLE 4)
C1
LENGTH: XX.XX 1%
01
02
02
'A'
"A" REF
(TYP)
"B" REF
(TYP)
N-1
(SEE TABLE 3)
.565 14.35
REF (TYP)
.775 19.69 REF
(TYP)
N-1
(SEE TABLE 3)
N
(SEE TABLE 3)
N
(SEE TABLE 3)
SUB-HQCD-X-XXX-XX-XX
STS-01
(TIGHTEN TO 1.4 - 1.7 IN-LBS)
(4 PLCS)
QCD-XX-01
HDRL-11
(SEE NOTE 5)
.253 6.42 REF (TYP)
FIRST END
SECOND END
LENGTH REF
* "C" REF
NOTES:
C
REPRESENTS A CRITICAL DIMENSION.
1.
2. SUB-TCF LENGTH IS EQUAL TO HQCD LENGTH.
C2
3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED
QCD-XX-02
FOR SHORTS AND OPENS.
SUB-TCF-3850-30-01-XX.XX
C3
4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V.
(SEE TABLE 1 FOR QTY)
5. TOP SUB-TCF NOT SHOWN IN THIS VIEW FOR CLARITY; HDRL-11 TO BE CENTERED ON LOWER
SUB-TCF AS SHOWN; HDRL-11 IS TO CONTAIN:
LINE 1 - PART NUMBER “HQCD-XXX-XX.XX-XXX-XXX-X-X”
LINE 2 - SHOP ORDER NUMBER “XXXXXX”
LINE 3 - DATE CODE “XXXXX”
THIS PRODUCT MANUFACTURED
Pb
6. FOR PACKAGING REQUIREMENTS REFERENCE PACKAGING STANDARDS.
WITH LEAD-FREE PROCESSING
* -DV END OPTIONS ONLY
7. PARTS TO BE PROCESSED PER SAMTEC ACCEPTABILITY
REQUIRMENTS: HDR-P1-01 "CABLE ASSEMBLY WORKMANSHIP STANDARDS".
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
8. CABLE LENGTHS LONGER THAN 40.00 INCHES ARE NOT SUPPORTED BY S.I. TEST DATA.
DIMENSIONS ARE IN INCHES.
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
9. RT1 OPTION IS NOT AVAILABLE WITH EDGEMOUNT OR PANEL MOUNT END OPTIONS.
TOLERANCES ARE:
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
10. RT1 OPTION IS NOT AVAILABLE WITH -120 POSITIONS.
DECIMALS
ANGLES
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
11. ALL POSITIONS TRANSMITTED AS SIGNALS ACROSS COAX CENTER CONDUCTORS. CONNECTOR
.XX: .01 [.3]
2
PURPOSE OTHER THAN THAT WHICH IT WAS
.XXX: .005 [.13]
GROUND BLADE TIED TO COAX SHIELD.
OBTAINED WITHOUT THE EXPRESSED WRITTEN
.XXXX: .0020 [.051]
CONSENT OF SAMTEC, INC.
DETAIL 'A'
SCALE 2.5 : 1
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 1:0.8
DESCRIPTION:
DWG. NO.
0.5mm HIGH-SPEED COAX CABLE ASSEMBLY
HQCD-XXX-XX.XX-XXX-XXX-X-X
04/29/03
SHEET
1
OF
8
c:\enterprisevault\DWG\MISC\MKTG\HQCD-XXX-XX.XX-XXX-XXX-X-X-MKT.SLDDRW
BY:
KEVIN B
stm8s output comparison - repeated thinking
The following is a program for output comparison. I'd like to ask all the experts to see where I went wrong!#include STM8S105C_S.h//unsigned int a;void GPIO_Init(void){PB_DDR=0XFF;PB_CR1=0XFF;PB_CR2=0...
guangxv stm32/stm8
Transfer 51 development board
[i=s]This post was last edited by liangben on 2015-2-16 10:01[/i] Transfer of Huijing Electronics, HJ-C52 development board, a board with relatively complete functions. It has 1602 LCD, stepper motor ...
liangben Buy&Sell
【RPi PICO】Run Fuzix system
Fuzix is a proper Unix, with multiple processes, devices, all the standard Unix tools, Bourne shell, vi clone, etc. Given the RP2040's limited RAM and no MMU, this port keeps just one process in memor...
dcexpert MicroPython Open Source section
【EVAL-M3-TS6-665PN】2. PFC working principle
[i=s]This post was last edited by ddllxxrr on 2019-8-4 09:34[/i]Just like programming, some English abbreviations come into view. I hate these abbreviations. Some people even enjoy them. I was reading...
ddllxxrr Power technology
Design of FPGA stepper motor subdivision driver
FPGA stepper motor subdivision drive design, please provide information...
风雨的承诺 FPGA/CPLD
The data sent by the Zigbee end device to the coordinator is lost
I used a waspmote software of zigbee to write the program My end-device can send data to the coordinator, but the first few packets are lost. Only once out of ten will you not lose What is going on? A...
Terrenceliu RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1332  2796  1771  174  1827  27  57  36  4  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号