Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: PWM 3882 circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
P50A13-R1B
PSU50A-13
Note.2
5V
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
P50A14-R1B
PSU50A-14
12V
2A
0.1 ~ 2.0A
100mVp-p
10%
1.0%
9.0%
135 ~ 370VDC
74%
5V
4A
0.5 ~ 4.0A
47W
50mVp-p
6.0%
1.0%
5.0%
100mVp-p
10%
1.0%
9.0%
15V
1.8A
0.1 ~1.8A
P50A16-R1B
PSU50A-16
5V
4A
0.5 ~ 4.0A
49W
50mVp-p
6.0%
1.0%
5.0%
100mVp-p
10%
1.0%
9.0%
24V
1A
0.1 ~ 1.0A
4A
0.5 ~ 4.0A
44W
RIPPLE & NOISE (max.)
Note.3
50mVp-p
Fixed
VOLTAGE TOLERANCE
Note.4
6.0%
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
Note.5
Note.6
1.0%
5.0%
90 ~ 264VAC
47 ~ 63Hz
70%
1.6A / 100VAC
40A / 230VAC
0.75mA / 240VAC
SETUP, RISE, HOLD UP TIME
1.5s, 50ms, 12ms at full load
INPUT
75%
150 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 110 ~ 140% of rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
0 ~ +40
(Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 approved
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
280K hrs min.
MIL-HDBK-217F (25
)
147*76*43mm (L*W*H)
0.55kg; 36pcs / 21kg / CARTON
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(
Note. 7
)
/ 70% RH
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Compliance to EN55022(CISPR22) class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
PLUG
CONNECTOR
CABLE
NOTE
OTHERS
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:P50A-D-SPEC 2007-05-14
44~49W AC-DC Dual Output Desktop
Mechanical Specification
P50A-D
series
Unit:mm
UL2464 18AWG 1220+100/-0
43
43
144.5
54.8
10.2
SWITCHING ADAPTOR
76
POWER LED
147
Plug Assignment
144.5
69.9
21.5
Standard plug: R1B (option)
PIN NO
OUTPUT
COM
COM
+5VDC
- Vout
+Vout
38
1
5 2 4
3
1
45
o
40
42
76
2
3
4
5
NAME PLATE
RUBBER FOOTX4
Derating Curve
Static Characteristics
100
100
LOAD (%)
LOAD (%)
80
60
60
0
10
20
30
40
0
50
60
70
80
90 100
260
Ta (
)
INPUT VOLTAGE
File Name:P50A-D-SPEC 2007-05-14
46.5~50W AC-DC Triple Output Desktop
Features :
3 pole AC inlet IEC320-C14
P50A-T
series
Class power (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Fix switching frequency and regulation
Topology: PWM 3882 circuit
LED indicator for power on
Approvals: UL / CUL / TUV / CB / CE
1 year warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
P50A13A-R1B
PSU50A-13A
Note.2
5V
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
P50A13D-R1B
PSU50A-13D
-5V
0.5A
0.1 ~ 0.5A
100mVp-p
12%
1.0%
10%
5V
4A
0.5 ~ 4.0A
50W
50mVp-p
6.0%
1.0%
5.0%
12V
2A
0.5 ~2.0A
100mVp-p
10%
1.0%
10%
-12V
0.5A
0.1 ~0.5A
100mVp-p
12%
1.0%
10%
P50A14E-R1B
PSU50A-14E
5V
4A
0.5 ~ 4.0A
50W
50mVp-p
6.0%
1.0%
5.0%
100mVp-p
10%
1.0%
10%
100mVp-p
12%
1.0%
10%
15V
1.5A
0.5 ~ 1.5A
-15V
0.5A
0.1 ~ 0.5A
12V
2A
0.5 ~ 2.0A
100mVp-p
10%
1.0%
10%
4A
0.5 ~ 4.0A
46.5W
RIPPLE & NOISE (max.)
Note.3
50mVp-p
Fixed
VOLTAGE TOLERANCE
Note.4
6.0%
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVERLOAD
Note.5
Note.6
1.0%
5.0%
90 ~ 264VAC
47 ~ 63Hz
70%
1.6A / 100VAC
40A / 230VAC
SETUP, RISE, HOLD UP TIME
1.5s, 50ms, 12ms at full load
135~ 370VAC
72%
74%
INPUT
0.75mA / 240VAC
150 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 110 ~ 140% of rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
0 ~ +40
(Refer to output load derating curve)
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1950, CSA22.2, EN60950-1 approved
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022(CISPR22) class B
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A
280K hrs min. MIL-HDBK-217F (25 )
147*76*43mm (L*W*H)
0.55kg; 36pcs / 21kg / CARTON
Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested
Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note. 7)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
PLUG
CABLE
CONNECTOR
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
[p=26, null, left][color=#000][font=Arial]The basic principle of PS2 keyboard decoding is to read the serial signal output by the keyboard through an external interrupt, and then perform table lookup ...
There is a feeling of touching the Internet. Even if it is called online love, as long as you really put your heart into it, it will take a lifetime to forget it. There is a simple metaphor: sunrise a...
:) Hardware design is different from software design. If there is a bug in the program, you can just rewrite it. Every error in hardware design means that you have to spend a lot of time and energy to...
After reading the document, I don't quite understand the coordinator and the terminal. Isn't it the terminal that implements the enroll request and the coordinator that implements the enroll response?...
Traditional broadcasting systems generally need to be operated manually at a fixed time, and can only realize one-way broadcasting with few functions. Traditional bell ringing equipment has a singl...[Details]
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
1. Circuit composition
The whole circuit consists of two parts:
1. Power saving control circuit
As shown in the figure below. Including delay circuit and drive circuit.
(1) Delay ci...[Details]
1. Introduction
With the growth of parking demand, the scale of parking lots is becoming larger and larger. A lot of research has been done on intelligent parking lots in China, but most of th...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
1. Introduction
This design was made for participating in an electronic design competition. It effectively solved the problem of the operation and control of an electric car on a seesaw. The s...[Details]
With the advent of increasingly powerful processors, image sensors, memory, and other semiconductor devices, as well as the algorithms that enable them, computer vision can be implemented in a wide...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
Converged processors meet scalability requirements
In current embedded system design, solutions based on MCU, DSP, FPGA and ASIC account for more than 90% of the market share. These solutions ...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]