EEWORLDEEWORLDEEWORLD

Part Number

Search

RPD-65

Description
65W Dual Output Switching Power Supply
File Size548KB,3 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Compare View All

RPD-65 Online Shopping

Suppliers Part Number Price MOQ In stock  
RPD-65 - - View Buy Now

RPD-65 Overview

65W Dual Output Switching Power Supply

65W Dual Output Switching Power Supply
Features :
Universal AC input/Full range
RPD-65
series
12V or 24V high peak output current capability
Optional L-Bracket and cover (RPD-65x-C, x=C,D)
Low leakage current<1mA
Protections: Short circuit / Overload / Over voltage
60W free air convection, 77.1W with 18CFM forced air
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK LOAD
RATED POWER
OUTPUT
OUTPUT POWER (max.)
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
(Note 5)
www. tuv.com
ID 2000000000
RPD-65C
CH1
12V
4.5A
0 ~ 5.8A
Note.4
7.5A
RPD-65D
CH2
5V
1.2A
0 ~ 1.5A
Rated load
CH1
24V
2.25A
0 ~ 2.9A
3.75A
60W
50mVp-p
±5.0%
±1.0%
±5.0%
150mVp-p
CH1:22.8 ~ 26.4V
±2.0%
±1.0%
±2.0%
50mVp-p
±5.0%
±1.0%
±5.0%
CH2
5V
1.2A
0 ~ 1.5A
Rated load
60W
Rated output power for convection; 77.1W with 18CFM min. forced air
RIPPLE & NOISE (max.)
Note.2
120mVp-p
CH1:11.4 ~ 12.8V
VOLTAGE TOLERANCE
Note.3
±2.0%
±1.0%
±2.0%
800ms, 20ms at full load
20ms at full load
90 ~ 264VAC
47 ~ 440Hz
79%
1.5A/115VAC
127 ~370VDC
81%
0.9A/230VAC
50A/230VAC
COLD START 25A/115VAC
<1mA
90 ~ 125W output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
CH1:27.6 ~ 32.4V
CH1:13.8 ~ 16.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-20 ~ +60
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
±
0.04%/
(0 ~ 50
) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1,
EAC TP TC 004
approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
288.1K hrs min. MIL-HDBK-217F (25
)
PCB:127*76*29mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H)
DIMENSION
PCB:0.24Kg; 63pcs/16Kg/1.35CUFT ; with optional CASE:0.47Kg;32pcs/16Kg/0.64CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 10% duty cycle maximum within every second. Average output power should not exceed the rated power, output voltage above 90% DC voltage.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5
/1000m with fanless models and of 5
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RPD-65-SPEC 2018-01-12

RPD-65 Related Products

RPD-65 RPD-65D RPD-65C
Description 65W Dual Output Switching Power Supply 65W Dual Output Switching Power Supply 65W Dual Output Switching Power Supply
I just saved the last question in my program. Can someone help me solve the last question?
If you do not press SET when saving, the data will not be saved to EEPROM if the power is turned off. I have changed it so that it will be saved to EEPROM automatically if you do not press SET. Can so...
pyy1980 MCU
I would like to ask, what is the maximum output speed of STM8's PWM? Is 2MHZ okay?
I would like to ask, what is the maximum output speed of STM8's PWM? Is 2MHZ okay?...
thedegree stm32/stm8
OrCAD uses components from the library to design
OrCAD uses components from the library to design...
guoxiao69 PCB Design
Programming Articles Network www.kingofcoder.com
Programming Articles Network www.kingofcoder.com...
张肖肖 Embedded System
Helper2416-10——Bare Metal Part 4——Turn off the dog & call C function (source code package attached)
[i=s]This post was last edited by yuanlai2010 on 2014-7-14 08:20[/i] [align=center][b][font=楷体, 楷体_GB2312][size=6][color=#008000]Keeping the dog and calling C functions[/color][/size][/font][/b][/alig...
yuanlai2010 Embedded System
Another UART implementation of launchPad
First of all, the so-called other method is relative to the method in the official temperature sensor routine. The official program is roughly like this, set to continuous counting mode, TXD, RXD as t...
shower.xu Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 664  2396  1185  1753  1889  14  49  24  36  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号