EEWORLDEEWORLDEEWORLD

Part Number

Search

RS-150-3.3

Description
Power Supply;AC-DC;12V@12.5A;88-132/176-264V In;Enclosed;Panel Mount;RS Series
CategoryPower/power management    The power supply circuit   
File Size104KB,2 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Download Datasheet Parametric Compare View All

RS-150-3.3 Overview

Power Supply;AC-DC;12V@12.5A;88-132/176-264V In;Enclosed;Panel Mount;RS Series

RS-150-3.3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Reach Compliance Codecompli
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Base Number Matches1
150W Single Output Switching Power Supply
RS-150
series
Features :
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
RS-150-3.3
3.3V
30A
0 ~ 30A
99W
RS-150-5
5V
26A
0 ~ 26A
130W
80mVp-p
4.75 ~ 5.5V
±2.0%
±0.5%
±1.0%
RS-150-12
12V
12.5A
0 ~ 12.5A
150W
120mVp-p
11.4 ~ 13.2V
±1.0%
±0.5%
±0.5%
RS-150-15
15V
10A
0 ~ 10A
150W
120mVp-p
14.25 ~ 16.5V
±1.0%
±0.5%
±0.5%
24V
6.5A
0 ~ 6.5A
156W
120mVp-p
www. tuv.com
ID 2000000000
RS-150-24
RS-150-48
48V
3.3A
0 ~ 3.3A
158.4W
200mVp-p
45.6 ~ 52.8V
±1.0%
±0.5%
±0.5%
RIPPLE & NOISE (max.)
Note.2
80mVp-p
3.2V ~ 3.5V
VOLTAGE TOLERANCE
Note.3
±3.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 6)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
Note.8
Note.4
±0.5%
Note.5
±2.0%
22.8 ~ 26.4V
±1.0%
±0.5%
±0.5%
800ms, 20ms/230VAC
28ms/230VAC
47 ~ 63Hz
74%
78%
1200ms, 30ms/115VAC at full load
248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)
84%
86%
87%
20ms/115VAC at full load
88 ~ 132VAC / 176 ~ 264VAC selected by switch
83%
3A/115VAC
2A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1
,
EAC TP TC 004
approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC
/ 25
/ 70% RH
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020
244KHrs min. MIL-HDBK-217F (25
)
199*98*38mm (L*W*H)
0.7Kg; 20pcs/15Kg/0.8CUFT
27.6 ~ 32.4V
55.2 ~ 64.8V
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
8. Extra consideration should be taken when selecting output wiring for 3.3V and 5V models. This is to prevent the protection modes for overload and short
circuit from becoming constant power.
9. The ambient temperature derating of 3.5
/1000m with fanless models and of 5
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RS-150-SPEC 2018-01-12

RS-150-3.3 Related Products

RS-150-3.3 RS-150-12 RS-150-5
Description Power Supply;AC-DC;12V@12.5A;88-132/176-264V In;Enclosed;Panel Mount;RS Series Power Supply;AC-DC;12V@12.5A;88-132/176-264V In;Enclosed;Panel Mount;RS Series Power Supply;AC-DC;12V@12.5A;88-132/176-264V In;Enclosed;Panel Mount;RS Series
Reach Compliance Code compli compli compli
Analog Integrated Circuits - Other Types AC-DC REGULATED POWER SUPPLY MODULE AC-DC REGULATED POWER SUPPLY MODULE AC-DC REGULATED POWER SUPPLY MODULE
Base Number Matches 1 1 1
Is it lead-free? Lead free - Contains lead
Can you please tell me the specific circuit to convert AC voltage signal into AC current signal? Thank you everyone
[size=4][font=Verdana, Helvetica, Arial, sans-serif][b]I want a specific circuit to convert AC voltage signal into AC current signal? Thank you all [/b][/font][/size][size=4][font=Verdana, Helvetica, ...
南极的天鹅 Integrated technical exchanges
New driver MM32F103 test (VIII) I2C
[size=3] Today I learned how to use the I2C module in the routine. I couldn't find a ready-made AT24Cxx module, so I found a PCF8574T module that I had made with a perforated board before, so I used i...
lising Motor Drive Control(Motor Control)
EEWORLD University Hall ---- Large-scale Data Processing and Cloud Computing Peking University
Large-Scale Data Processing and Cloud Computing Peking University : https://training.eeworld.com.cn/course/5182Cloud computing technology is a model for the increase, use and delivery of Internet-base...
抛砖引玉 DIY/Open Source Hardware
Problems with extended serial port chip driver
PXA270+WinCE6.0 expands 4 serial ports through bus expansion serial port chip ST16c554. I don't know enough about serial ports. What should I pay attention to when writing the driver for the extended ...
tsz Embedded System
Does anyone know which chip the default ADC in EWB is?
[i=s] This post was last edited by dontium on 2015-1-23 13:26 [/i] Does anyone know which chip the default ADC in EWB is? Can you tell me? Thank you, I used that chip for my design and the simulation ...
xuwq2 Analogue and Mixed Signal
LPC1500 experience + SCT_1, register
[i=s]This post was last edited by freebsder on 2014-8-15 21:59[/i] [align=left][color=black][font=SimSun][size=10.5pt]1. The UNIFY bit in the CONFIG register sets whether the timer is used as one 32-b...
freebsder NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1268  2589  1527  2490  141  26  53  31  51  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号