EEWORLDEEWORLDEEWORLD

Part Number

Search

440F-C252D

Description
Safety Edges
File Size69KB,3 Pages
ManufacturerALLEN BRADLEY
Download Datasheet Compare View All

440F-C252D Overview

Safety Edges

Presence Sensing Safety Devices
Safety Edges
Safedge™ Controllers
Specifications
Standards
Safety Category
Approvals
Power Supply 251
252
Power Consumption 251
252
Fuses, Internal 251D, 251P
251P
252D
EN1760-2, EN954-1, ISO 13849-1,
AS4024.5, EN954-1, ANSI B11.19
Cat. 3 per EN954-1
CE marked for all applicable directives,
cULus, TuV
24V AC/DC or 110/230V AC 50/60Hz
24V AC/DC 50/60Hz
<6VA
<4VA
500mA Power Supply, Replaceable
2 x 2A Safety Output, Replaceable
500mA, Resettable
4A on AC, 2A on DC
6KΩ, 12V DC open circuit, 4V DC run
condition
1 N.O.
9KΩ
1KΩ
2 N.O.
1 N.O.
1 N.C.
2A/250V AC, 2A/125V AC
1A/30V DC
10mA/10V
13ms
Green = Run
Yellow = Open Circuit
Red = Stop
2500V
C in accordance with VDE0110
3
-10°C to 55°C (-14°F to 131°F)
90% RH
IP40 (NEMA 1)
IP65 (NEMA 13)
IP20 DIN 0470
1 x 4mm
2
(10AWG) stranded
1 x 4mm
2
(10 AWG) solid
1 x 1.1mm
2
(18AWG) stranded
1 x 1.5mm
2
(16AWG) solid
Polycarbonate
181g (0.4lbs)
450g (1.0lbs)
650g (1.4lbs)
0.15mm 10-55Hz
10g, 11ms half sine
Description
The Safedge controllers are designed to operate with the Safedge
profiles. The controller continuously monitors the profile for
actuation and generates an output signal when the profile is
depressed.
The Safedge controller provides a low voltage to the profile. When
the profile is pressed, the controller detects a change in resistance
and turns off its output relays. When pressure is released from the
profile, the output relays of the controller return to an on state. The
controller has redundant voltage free positively-guided output relays
which can be used to interface with a machine control system.
The ‘251’ controller comes capable of operating at 24V AC/DC, or
120/230V AC from separate terminals. An internal switch changes
the operating voltage from 120V AC to 230V AC. The ‘252’
controller operates at 24V AC/DC.
An auxiliary output relay is available to provide a signal about the
controller’s status. Three LEDs indicate whether the controller is in
RUN, STOP or OPEN condition. The controller operates in manual
or automatic reset mode.
Fuses, External
Safety Input Profile
Monitoring
Maximum Input Impedance
Profile
Monitoring Circuit
Outputs 251 Safety
252 Safety
251, 252 Auxiliary
Output Rating
Min. Switching Current/Volt.
Max. Response Time
Indication LEDs
Impulse Withstand Voltage
Installation Group
Pollution Degree
Operating Temperature
Humidity
Enclosure Protection
251D, 252D
251P
Terminal Protection
Max Conductor Size
251D, 252D
251P
Case Material
Weight 252D
251D
251P
Vibration
Shock
Features
1 N.O. or 2 N.O. Safety Outputs
1 N.C. Auxiliary Output
24V AC/DC or 120/240V AC
Output Monitoring
LED Indicators for RUN, STOP and OPEN
Automatic/Manual Reset
2-103

440F-C252D Related Products

440F-C252D 440F-C251D 440F-C251P 440A-A09197
Description Safety Edges Safety Edges Safety Edges Safety Edges
Motorola Electronic Design Competition Outstanding Works (Part 7)
[i=s]This post was last edited by paulhyde on 2014-9-15 08:54[/i]...
clark Electronics Design Contest
The LM3S811 program I wrote in school before! The comments are very detailed.
[size=7]Some practice programs I wrote when I participated in an electronic design competition. The comments are very detailed. If you are using the LM3S811 development board, you can take a look. It ...
jinghong21 Microcontroller MCU
xp system and virtual operating system linux in microsoft, how to let linux surf the internet
Description: The network configuration of my real host: IP Address (192.168.16.95) Gateway is (192.168.16.1) DNS is (202.96.134.133) I access the Internet through the landlord's hub. It binds my IP to...
yinfei0809 Linux and Android
TI 28027 program cannot enter interrupt
0, 23, 47, 70, 94, 117, 141, 164, 187, 211, 234, 257, 281, 304, 327, 350, 373, 395, 418, 441, 536, 572, 584, 612, 622, 636, 647, 650, 664, 672, 684, 702, 712, 728, 736, 750, 764, 772, 784, 792, 802, 8...
the_wanted Microcontroller MCU
[MSP430] Questions about Chinese character font data structure
typedef struct typFNT_GB12 { char Index[2]; //What does internal code index mean? uint8_t Msk[24]; //I roughly know the meaning of dot matrix code data size}GB12; Chinese character font data structure...
woaiweibo Microcontroller MCU
GPIO Operation of TMS320C6748
GPIO Features of TMS320C6748 Referring to the 1.2Features section of the TI technical document SPRUFL8B (TMS320C674x/OMAP-L1x Processor GPIO User's Guide), we can see that the GPIO of the TMS320C6748 ...
fish001 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 667  2910  1233  2399  1829  14  59  25  49  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号