EEWORLDEEWORLDEEWORLD

Part Number

Search

BK8/MDA-1-1/2V

Description
Electric Fuse, Time Delay Blow, 1.5A, 250VAC, 100A (IR), Through Hole
CategoryCircuit protection    Circuit protection   
File Size131KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK8/MDA-1-1/2V Overview

Electric Fuse, Time Delay Blow, 1.5A, 250VAC, 100A (IR), Through Hole

BK8/MDA-1-1/2V Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsTIME DELAY
body height32.82 mm
Body length or diameter6.76 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal25 J
Manufacturer's serial numberMDA
Installation featuresTHROUGH HOLE
method of packingBOX
physical size6.76mm x 32.82mm
Rated breaking capacity100 A
Rated current1.5 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapePIN WIRE
Base Number Matches1
1/4" x 1-1/4" Fuses
MDA Series, Time Delay, Ceramic Tube
Description
• Time Delay, ceramic tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
Rated Current
Amp Rating
Opening Time
100%
None
1/4 - 30A
135%
60 Minutes Max.
200%
120 Seconds Max.
RoHS
2002/95/EC
Agency Information
• UL Listed Card: MDA 2/10 - 20A (Guide JDYX,
File E19180)
• UL Recognized Card: MDA 25 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDA 2/10 - 20
(Class No. 1422-01)
• CSA Component Acceptance: MDA 25-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 207,
(HI Shock)
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Dimensions
(
mm
in
)
Drawing Not to Scale
SPECIFICATIONS
Product
Code
MDA-1/4
MDA-1/2
MDA-3/4
MDA-1
MDA-1-1/2
MDA-2
MDA-2-1/2
MDA-3
MDA-4
MDA-5
MDA-6
MDA-7
MDA-8
MDA-10
MDA-12
MDA-15
MDA-20
MDA-25A
MDA-30A
*
**
Traditional Ferrule Fuses - Ferrule Type
Voltage
Rating
AC
DC
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
-
250V
125V
250V
125V
250V
125V
AC Interrupting
Rating*
250V
125V
35A
10000A
35A
10000A
35A
10000A
35A
10000A
100A
10000A
100A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
750A
10000A
750A
10000A
1500A
10000A
1500A
10000A
1500A
10000A
DC Interrupting
Rating
125V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10000A
10000A
10000A
Typical DC Cold
Resistance**
(ohms)
9.325
1.925
0.8555
0.560
0.2585
0.1645
0.06685
0.0507
0.0346
0.02355
0.01850
0.01475
0.01230
0.00858
0.00725
0.00543
0.00358
0.00309
0.00243
Typical
Melting I
2
t†
AC
0.68
2.3
7.8
11.1
25.0
64.0
28.9
40.9
134.0
345.9
534.3
580.3
944.0
1491.3
113.8
206.2
439.5
667.9
997.0
Typical
Voltage
Drop‡
4.00
1.42
1.31
1.03
0.691
0.623
0.213
0.182
0.162
0.145
0.141
0.137
0.134
N/A
0.114
0.107
0.095
0.105
0.110
Interrupting Ratings (Measured at 70% - 80% power factor on AC. The interrupting ratings for 25Amp, 30Amp were measured at 90% - 100% power factor on AC)
DC Cold Resistance (Measured at
≤10%
of rated current)
Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage)
Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
OC-86
Our summer college students are innovating and using CC3200 board
We are doing college student innovation during the summer vacation. We use CC3200 board and follow the process of TI company to remotely control the on and off of LED-7. But why did the LED flicker in...
zhangchenhui TI Technology Forum
Storage test anvilpro
Anvil's Storage Utilities is a software designed specifically for SSD testing (it also supports mechanical hard drives). It is quickly becoming one of the newest de facto standard test programs for ha...
白丁 Integrated technical exchanges
12864 LCD display problem
The LCD screen can display normally on a development board with STM8S105K4 chip, but it can't display the menu on another development board with STM8S105S4 chip. The pin configuration and definition a...
Mavine stm32/stm8
Research on Flash Code Performance in 2812 Search Warrant + TMS320F2812 Chip Development
Research on Flash code performance in TMS320F2812 chip development. If you are interested, please go and have a look.[[i]This post was last edited by hangsky on 2011-11-8 13:36[/i]]...
hangsky Microcontroller MCU
Is there something wrong? Always prompts that the device is not connected
[code] LPCWSTR strDrvName=L""; strDrvName=TEXT("NDS0:"); HANDLE hHandle; hHandle = CreateFile(strDrvName, GENERIC_READ | GENERIC_WRITE, FILE_SHARE_READ | FILE_SHARE_WRITE, NULL, OPEN_EXISTING, FILE_AT...
pmns Embedded System
Effectively address antenna design issues in multi-band mobile phones
The RF signal channels in today's mobile phones are becoming increasingly crowded. Cellular phones have rapidly evolved from dual-band to tri-band and even quad-band. These complex mobile phones also ...
clj2004000 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1182  1039  141  521  1735  24  21  3  11  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号