EEWORLDEEWORLDEEWORLD

Part Number

Search

BK8/MDA-6-RB

Description
Electric Fuse, Time Delay Blow, 6A, 250VAC, 200A (IR), Inline/holder, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size272KB,2 Pages
ManufacturerCooper Industries
Environmental Compliance
Download Datasheet Parametric View All

BK8/MDA-6-RB Overview

Electric Fuse, Time Delay Blow, 6A, 250VAC, 200A (IR), Inline/holder, ROHS COMPLIANT

BK8/MDA-6-RB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Fusing characteristicsTIME DELAY
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal587 J
Manufacturer's serial numberMDA
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current6 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeEND CAP
Base Number Matches1
/
4
˝ x 1
1
/
4
˝ Ceramic Tube Fuses
MDA Series,
Time-Delay
1
Description
• Time-delay
• Optional axial leads available
• 1/4˝ x 1-1/4˝ (6.35 x 31.75mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Electrical Characteristics
Rated Current
Amp Rating
Opening Time
100%
None
1/4 - 30A
135%
60 Minutes Max.
200%
120 Seconds Max.
Dimensions - mm (in)
Drawing Not to Scale
38.10
(1.500)
32.82
(1.292)
38.10
(1.500)
Agency Information
• UL Listed Card: MDA 2/10 - 20A (Guide JDYX,
File E19180)
• UL Recognized Card: MDA 25 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDA 2/10 - 20
(Class No. 1422-01)
• CSA Component Acceptance: MDA 25-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 213,
Test Condition J
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
6.76
(0.266)
DIA. OF LEADS
0.81
0–15 AMP:
(0.032)
20–30 AMP: 1.02
(0.040)
31.75
(1.250)
6.35
(0.250)
Ordering
• Specify packaging, product, and option code
SPECIFICATIONS
Part
Number
MDA-1/4-R
MDA-1/2-R
MDA-3/4-R
MDA-1-R
MDA-1-1/2-R
MDA-2-R
MDA-2-1/2-R
MDA-3-R
MDA-4-R
MDA-5-R
MDA-6-R
MDA-7-R
MDA-8-R
MDA-10-R
MDA-12-R
MDA-15-R
MDA-20-R
MDA-25A-R
MDA-30A-R
*
**
Voltage
Rating
Vac
Vdc
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
125
250
125
250
125
AC Interrupting
Rating* (amps)
250V
125V
35
10000
35
10000
35
10000
35
10000
100
10000
100
10000
200
10000
200
10000
200
10000
200
10000
200
10000
200
10000
200
10000
200
10000
750
10000
750
10000
1500
10000
1500
10000
1500
10000
DC Interrupting
Rating (amps)
125V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10000
10000
10000
Typical DC Cold
Resistance**
Ω
(Ω)
9.325
1.925
0.8555
0.560
0.2585
0.170
0.06685
0.05350
0.03625
0.02610
0.02120
0.01690
0.01350
0.00948
0.00725
0.00553
0.00400
0.00305
0.00243
Typical
Melting I
2
t†
AC
0.748
2.53
8.58
12.21
27.5
70.4
31.79
44.99
147.4
380.49
587.73
638.33
1038.4
1620.43
125.18
336.82
483.45
734.69
1096.7
Typical
Voltage
Drop‡
4.00
1.42
1.31
1.03
0.691
0.623
0.213
0.182
0.162
0.145
0.141
0.137
0.134
0.135
0.128
0.107
0.095
0.105
0.110
Interrupting Ratings (Measured at 70% - 80% power factor on AC. The interrupting ratings for 25Amp, 30Amp were measured at 90% - 100% power factor on AC)
DC Cold Resistance (Measured at ≤10% of rated current)
Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage)
Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
0709
SB-BU09312
Page 1 of 2
Data Sheet 2002
EEworld Download Center contributes to the Msp430 microcontroller video tutorial
MSP430 MCU Video Tutorial Special Topic 1. Lecture 1_Overview 2.0 Lecture 2_Reset, Interrupt and IO 2.1 Lecture 2_Reset, Interrupt and IO (Supplement) (Supplement) .3.[font=宋体]Lecture 3[/font][font=He...
tiankai001 Download Centre
Differences between MSP430 programmer emulator and JTAG, SBW, and BSL interfaces
[color=#000][font=Arial]For 51 system, it is easy to understand programmer and emulator. [/font][/color] [color=#000][font=Arial]In layman's terms, emulator is used for debugging simulation, and progr...
qinkaiabc Microcontroller MCU
Variable declaration and definition
[align=center][size=5][b] Declaration and Definition of Variables[/b][/size][/align][align=left]Understanding the difference between "declaration" and "definition" is crucial in understanding the C la...
tiankai001 Download Centre
TCPMP player source code discussion
How do I know when the audio or video file has finished playing when using TCPMP player? I searched and saw several flag variables and commands. [code]if (StopIfEnd && p->ExitAtEnd) Notify(p,PLAYER_EX...
月光 Embedded System
Need help with the on-chip operational amplifier of 430F149?
Which IO ports does the on-chip operational amplifier (OA0, etc.) of 430F149 input and output from? I haven't seen any related configuration in the manual? I haven't seen any introduction to this on-c...
hit09 Microcontroller MCU
Lessons about cross-platform C structure bit fields (transferred)
The C language STRUCT provides a syntax called bit field, which can determine the member's occupation of a byte from bit X to bit Y as needed. For example, the following structure: struct tagtest { ch...
bootloader Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 266  2493  950  1451  2438  6  51  20  30  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号