EEWORLDEEWORLDEEWORLD

Part Number

Search

ERCD-040-08.00-STL-TBR-2-B

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size834KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

ERCD-040-08.00-STL-TBR-2-B Overview

Interconnection Device, ROHS COMPLIANT

ERCD-040-08.00-STL-TBR-2-B Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
F-211-1
(0,80mm) .0315"
ERCD SERIES
ERCD–050–08.00–SBR–STR–1–D
ERCD–020–10.00–TEU–STR–1–R
EDGE RATE COAX CABLE ASSEMBLIES
SPECIFICATIONS
i
For complete specifications and
recommended PCB layouts see
www.samtec.com?ERCD
Cable:
34 AWG coax ribbon cable
Signal Routing:
50Ω Single-Ended
Plating:
Au over 50µ" (1,27µm) Ni
Operating Temp Range:
-25°C to +105°C
RoHS Compliant:
Yes
Mates with:
ERF8, ERM8
Broadside wiping
contacts reduce
unwanted
crosstalk
Cable
Length
6" (152,4mm)
Rated @ 7dB
Insertion Loss
ERCD
34 AWG
micro ribbon
coax cable
6.37 GHz / 12.74 Gbps
39.37" (1m)
2.19 GHz / 4.38 Gbps
Performance data for other cable lengths
and complete test data available at
www.samtec.com?ERCD or contact
sig@samtec.com
(0,80mm)
.0315" pitch
Rugged metal
latching system
Patent Pending
ERCD
NO. POSITIONS
PER ROW
WIRE
LENGTH
END
NO. 1
END
NO. 2
WIRING
OPTION
LATCH
END TO END
DV to DV
DV to Edge Mount (-TEX)
Edge Mount (-TEX)
POSITIONS
PER ROW
–010
–020
–030
–040
–050
–060
B
(23,47)
.924
(26,69)
1.051
(29,92)
1.178
–010, –020, –030,
–040, –050, –060
OAL = Wire Length +
B
02
01
–“XX.XX”
= Wire Length
in Inches
(95,3mm) 03.75"
minimum
–TTR
= Terminal, Top Right
–1
= Pin 1 to
Pin 1
Latch is
required
–TTL
= Terminal, Top Left
–2
= Pin 1 to
Pin 2
–L
= End No. 1
Standard Latch,
End No. 2
Squeeze Latch
(TEX only)
–TBR
02
= Terminal, Bottom Right
01
–3
= Pin 1 to
Pin N -1
–TBL
= Terminal, Bottom Left
A
(22,66) .892
(30,66) 1.207
(38,66) 1.522
(46,66) 1.837
(54,66) 2.152
(62,66) 2.467
–4
= Pin 1 to
Pin N
–R
= End No. 1
Squeeze Latch
(TEX only),
End No. 2
Standard Latch
–STR
= Socket, Top Right
A
–STL
= Socket, Top Left
–D
= Both Ends
Standard
Latch
Note:
Cable lengths longer than
40.00" (1 meter) are not
supported with S.I. test data.
–SBR
= Socket, Bottom Right
(18,75)
.738
–SBL
= Socket, Bottom Left
–N
= No Caps
(Both ends have
Latch option)
Note:
Verify part number and correct
wiring scheme with Samtec’s
Interactive Cable Builder at
www.samtec.com/cable_
builder/pitch.aspx
Note:
Some lengths, styles and
options are non-standard,
non-returnable.
–TEU
(10,15)
.400 (7,72)
.304
(13,76)
.542
= Terminal,
Edge Mount Up
–TED
END NO.1
(–STL SHOWN)
END NO.2
(–TTR SHOWN)
= Terminal,
Edge Mount Down
= Both ends
have Squeeze
Latch
(TEX only)
–B
WWW.SAMTEC.COM
The legendary LabVIEW graduation thesis
I will provide two first. I really can't download them anymore. If you want to download them, you can go and have a look. Remember to give me a thumbs up!! Thank you! Please give me a thumbs up just f...
chaoren Test/Measurement
If there is no reference ground at all, do you think it is still possible to control the impedance?
Author: Huang Gang, member of YiBo Technology Expressway Mr.As an SI engineer, PCB design engineer, or even a hardware engineer and test engineer, calculating transmission line impedance is definitely...
yvonneGan PCB Design
Photo report of the 7th Beijing International Pure Electric and Hybrid Vehicle Exhibition
On the morning of July 3rd, when the sun was shining brightly, Aniu went to Jing'anzhuang National Exhibition to attend the International Pure Electric and Hybrid Vehicle Exhibition. AVNET exhibited I...
jameswangsynnex Energy Infrastructure?
Weekly highlights: 2017.8.28-2017.9.3
[size=4]Hi, good morning, everyone~~ I got up early today~~~:loveliness: I'll quickly send you some wonderful stuff~[/size] [size=4][color=#ff0000][b]Recommended wonderful posts:[/b][/color][/size] [s...
okhxyyo Energy Infrastructure?
How to solve the problem of "The breakpoint will not be hit currently. The specified module has not been loaded" when debugging in vs2005+wince5.0 simulator?
How to solve the problem "The breakpoint will not be hit. The specified module has not been loaded" when debugging in vs2005+wince5.0 simulator? A simple form+button program, when the device is wince5...
cattyzeal Embedded System
Power engineers are most afraid of EMC, analyze it like this! (Reposted)
[size=4] As the speed of switching power supplies is getting faster and faster, the power is getting higher and higher, and the density is getting larger and larger, interference problems will inevita...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1765  2595  1712  2278  2450  36  53  35  46  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号