EEWORLDEEWORLDEEWORLD

Part Number

Search

DP-FLEX

Description
Two-Zone Fire Alarm Control Panel
File Size64KB,2 Pages
ManufacturerGamewell-FCI ( Honeywell )
Websitehttp://www.gamewell-fci.com
Download Datasheet Compare View All

DP-FLEX Overview

Two-Zone Fire Alarm Control Panel

Features
Flex 402
Two-Zone Fire Alarm Control Panel
Description
The Gamewell Flex 402 Fire Alarm
Control Panel brings the latest in mi-
croprocessor technology to conven-
tional fire controls. The Flex 402 is
compatible with the new
™ smoke
detectors from System Sensor, and
provides advanced features including
drift compensation, maintenance alert,
and freeze warning. Automatic synchro-
nization of audio/visual devices is pro-
vided, selectable for three manufactur-
ers’ protocols. The NAC protocol in-
cludes the ability, using a single pair of wires, to silence audible devices while
strobes continue to flash.
The Flex 402 is also compatible with conventional input devices such as two-
and four-wire smoke detectors, pull stations, waterflow devices, tamper switches
and other normally-open contact devices.
g2402ph1.jpg
Operation
The activation of a compatible smoke detector or any normally-open fire alarm
initiating device will: activate audible and visual signaling devices, illuminate an
indicating LED, sound the piezo sounder at the FACP, activate the FACP alarm
relay, and operate an optional module which notifies a remote station or initiates
an auxiliary control function.
i³™
Technology Features
• Drift compensation automatically adjusts detector sensitivity and increases
resistance to false alarms caused by dust accumulation.
• The maintenance alert LEDs (per zone) warn of excessive dirt accumulation,
preventing false alarms.
• Detector sensitivity is automatically measured. The twice-yearly test require-
ments of NFPA 72 (7-3.2.1) are met without using a ladder or test meter.
• The wireless handheld sensitivity meter eliminates the need for voltmeters,
magnets, or a physical connection to the detector. The reader displays sensi-
tivity in terms of percent-per-foot obscuration and provides text status indica-
tion.
• The supervisory LED (per zone) provides a warning if a detector senses tem-
peratures approaching freezing.
• Special test protocol and LED indication allow a quick test of all detectors —
without a ladder.
• Electronic heat-sensing element provides thermal detection in addition to pho-
toelectronic smoke detection.
Flex 402 Two-Zone FACP
CS-2402 09/01/06
Page 1 of 2
• Two Style B (Class B) Initiating Device
Circuits (IDCs).
• One Style Y (Class B) Notification Appliance
Circuit (NAC).
• 24 VDC.
NAC synchronization features:
– Provides synchronization of standard ANSI
audible signals as required by NFPA 72
(3-8.4.1.2.3).
– Provides synchronization of ADA compliant
strobes per NFPA 72 (4-4.4.1).
– Selectable for System Sensor, Wheelock,
and Gentex protocols.
– Selective Silence feature allows manual
silencing of horns while strobes continue to
flash on the same NAC.
• Silent or Audible Walk Test operation mode
commanded from the front keypad, with
automatic return to normal after one hour of
inactivity.
• Alarm verification selectable per zone.
• Each zone may be programmed for
supervisory or fire; each zone has separate
red and yellow LEDs.
• Disable switches provided for each zone.
NACs programmable for:
Silence Inhibit, Auto
Silence, Strobe Synchronization, Selective
Silence (horn/strobe mute), Temporal or
Steady signal, Silenceable or
Nonsilenceable.
• Form-C Alarm and Trouble relays.
• 3.0 amps total usable current.
• Optional dress panel (P/N
DP-FLEX).
• Piezo sounder for alarm, trouble, supervisory,
and maintenance.
Control buttons:
ACK (Acknowledge), Alarm
Silence, Reset, Walktest,
Zone Enable/Disable (one per zone).
LED indicators:
Fire Alarm (one per zone),
Supervisory (one per zone), Trouble (one
per zone), Maintenance (one per zone),
AC Power, NAC Disable, Zone Disable,
NAC Fault, System Trouble, Power Trouble,
Walktest, Alarm Silence, Earth Fault (on
circuit board), Battery Fault (on circuit board),
Charger Fault (on circuit board).
Listings
Listings and approvals below apply to the
basic Flex 402 panel. In some cases, certain
modules may not be listed by certain
approval agencies, or listing may be in
process. Consult factory for latest listing
status.
• UL Listed: file S521.
• CSFM approved: file 7165-1288-180.
• MEA approved: file 366-04-E.

DP-FLEX Related Products

DP-FLEX BB-17F F402 TR-1-R 52194
Description Two-Zone Fire Alarm Control Panel Two-Zone Fire Alarm Control Panel Two-Zone Fire Alarm Control Panel Two-Zone Fire Alarm Control Panel Two-Zone Fire Alarm Control Panel
Introduction to eight surface treatment processes for PCB boards
As human beings' requirements for living environment continue to increase, the environmental issues involved in the current PCB production process are particularly prominent. The topic of lead and bro...
ohahaha PCB Design
Altium Designer 13.1.2 Download (with crack and tutorial)
[i=s]This post was last edited by froglucky on 2014-4-18 15:04[/i] [align=left][font=Verdana][size=2][color=#ff0000]Software Introduction:[/color][/size][/font][/align][align=left][font=Verdana][size=...
froglucky Download Centre
Questions about learning ARM
What is the use of learning ARM architecture and assembly instructions? ? Please give me some advice...
brett1753 ARM Technology
I'm looking at mpu9250 recently. Does anyone know where to download DMP information from InvenSense's official website?
rt, I'm looking at mpu9250 recently. Does anyone know where to download DMP information from InvenSense's official website? I searched several times but couldn't find it. It's also difficult to regist...
BlackHeart4theW stm32/stm8
DSP Hardware Papers
DSP Hardware Papers...
呱呱 MCU
Brightness calculation method of LED electronic display screen
Calculation method of brightness of LED electronic display: Taking full-color screen as an example, the red, green, blue and white balance ratio is usually 3:4:1   Take P16 (2R1GB) 5000 CD/square as a...
张无忌1987 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2504  579  1334  880  374  51  12  27  18  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号