CAUTION: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation
of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Potentiometer Specifications
V
CC
= Full Range, T
A
= Full Operating Temperature Range unless otherwise stated
SYMBOL
R
TOTAL
V
RH
/
RL
PARAMETER
End to end resistance tolerance
R
H
/R
L
terminal voltage
Power rating
TEST CONDITIONS/NOTES
See ordering information for values
V
SS
= 0V
R
TOTAL
≥
10kΩ
R
TOTAL
= 1kΩ
R
W
Wiper resistance
I
W
= 1mA, V
CC
= 5V
I
W
= 1mA, V
CC
= 2.7V
I
W
Wiper current (Note 5)
Noise (Note 7)
Resolution
Absolute linearity (Note 1)
Relative linearity (Note 2)
R
TOTAL
temperature coefficient (Note 5)
Ratiometric temperature coefficient
(Notes 5, 6)
C
H
/C
L
/C
W
(Note 5)
V
CC
Potentiometer capacitances
Supply Voltage
See equivalent circuit
X9317
X9317-2.7
4.5
2.7
-20
10/10/25
5.5
5.5
V(RH) = V
CC
,
V(RL) = 0V
-1
-0.2
±300
+20
See test circuit
Ref: 1kHz
-4.4
-120
1
+1
+0.2
200
400
MIN
-20
V
SS
TYP
(Note 4)
MAX
+20
V
CC
10
25
400
1000
+4.4
UNIT
%
V
mW
mW
Ω
Ω
mA
dBV
%
MI
(Note 3)
MI
(Note 3)
ppm/°C
ppm/°C
pF
V
V
DC Electrical Specifications
SYMBOL
I
CC1
V
CC
= 5V ±10%, T
A
= Full Operating Temperature Range unless otherwise stated
TEST CONDITIONS
CS = V
IL
, U/D = V
IL
or V
IH
and INC =
V
IL
/V
IH
@ min. t
CYC
R
L
, R
H
, R
W
not connected
CS = V
IH
, U/D = V
IL
or V
IH
and INC = V
IL
or V
IH
. R
L
, R
H
, R
W
not connected
CS
≥
V
IH
, U/D and INC = V
IL
R
L
, R
H
, R
W
not connected
V
IN
= V
SS
to V
CC
-10
V
CC
x
0.7
-0.5
MIN
TYP
(Note 4)
MAX
50
UNIT
µA
PARAMETER
VCC active current (Increment)
I
CC2
I
SB
I
LI
V
IH
V
IL
VCC active current (Store)
(non-volatile write)
Standby supply current
CS, INC, U/D input leakage current
CS, INC, U/D input HIGH voltage
CS, INC, U/D input LOW voltage
400
1
+10
V
CC
+
0.5
V
CC
x
0.1
µA
µA
µA
V
V
3
FN8183.0
X9317
DC Electrical Specifications
SYMBOL
C
IN
(Note 5)
V
CC
= 5V ±10%, T
A
= Full Operating Temperature Range unless otherwise stated
(Continued)
TEST CONDITIONS
V
CC
= 5V, V
IN
= V
SS
, T
A
= 25°C,
f = 1MHz
MIN
TYP
(Note 4)
MAX
10
UNIT
pF
PARAMETER
CS, INC, U/D input capacitance
Endurance and Data Retention
V
CC
= 5V ±10%, T
A
= Full Operating Temperature Range
PARAMETER
Minimum endurance
Data retention
NOTES:
1. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = [V(R
W(n)(actual)
)-V(R
W(n)(expected)
)]/MI
V(R
W(n)(expected)
) = n(V(R
H
)-V(R
L
))/99 + V(R
L
), with n from 0 to 99.
2. Relative linearity is a measure of the error in step size between taps = [V(R
W(n+1)
)-(V(R
W(n)
) - MI)]/MI.
3. 1 Ml = Minimum Increment = [V(R
H
)-V(R
L
)]/99.
4. Typical values are for T
A
= 25°C and nominal supply voltage.
5. This parameter is not 100% tested.
6. Ratiometric temperature coefficient = (V(R
W
)
T1(n)
-V(R
W
)
T2(n)
)/[V(R
W
)
T1(n)
(T1-T2) x 10
6
], with T1 & T2 being 2 temperatures, and n from 0 to 99.
7. Measured with wiper at tap position 99, R
L
grounded, using test circuit.
MIN
100,000
100
UNIT
Data changes per bit
Years
Test Circuit
Equivalent Circuit
R
TOTAL
R
H
C
H
Force
Current
C
W
25pF
10pF
R
W
C
L
10pF
R
L
Test Point
R
W
A.C. Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
AC Electrical Specifications
SYMBOL
t
Cl
t
lD
(Note 5)
t
DI
(Note 5)
t
lL
t
lH
t
lC
t
CPHS
t
CPHNS
(Note 5)
t
IW
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
V
CC
= 5V ±10%, T
A
= Full Operating Temperature Range unless otherwise stated
MIN
50
100
1
960
960
1
10
100
1
5
TYP (Note 4)
MAX
UNIT
ns
ns
µs
ns
ns
µs
ms
ns
µs
PARAMETER
INC inactive to CS inactive
CS deselect time (STORE)
CS deselect time (NO STORE)
INC to R
W
change
4
FN8183.0
X9317
AC Electrical Specifications
SYMBOL
t
CYC
t
R
, t
F
(Note 5)
INC cycle time
INC input rise and fall time
V
CC
= 5V ±10%, T
A
= Full Operating Temperature Range unless otherwise stated
(Continued)
MIN
2
500
5
0.2
5
50
10
TYP (Note 4)
MAX
UNIT
µs
µs
µs
V/ms
ms
PARAMETER
t
PU
(Note 5) Power up to wiper stable
t
R
V
CC
(Note 5)
t
WR
VCC power-up rate
Store Cycle
Power Up and DOWN Requirements
The recommended power up sequence is to apply V
CC
/V
SS
first, then the potentiometer voltages. During power-up, the
data sheet parameters for the DCP do not fully apply until 1
millisecond after V
CC
reaches its final value. The V
CC
ramp
spec is always in effect. In order to prevent unwanted tap
position changes, or an inadvertent store, bring the CS and