A100EHI
Series
Low Cost, Miniature DIP
1W, Very High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
1W Output Power
•
6,000 VDC Isolation
•
UL Approved
(File E245422)
•
-40
º
C to 85
º
C Operation
•
24 Pin DIP Case
•
5V and 12V Inputs
•
Single & Dual Outputs
•
16 Standard Models
•
3.5 MH MTBF
•
LOWEST COST!!
Input
Parameter
Input Voltage Range
Input Filter
Short Circuit Input Power
Conditions
5 VDC Input
12 VDC Input
Min.
4.5
10.8
Typ.
5.0
12.0
Max.
5.5
13.2
1,500
Conditions
Dual Output , Balanced Loads
For Vin Change of 1%
Iout = 10% to 100%
Iout = 10% to 100%
75
120
±0.01
Momentary (1.0 Seconds)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
6,000
1,000
2
250
Conditions
Ambient
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
Max.
+85
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
±0.03
Min.
Typ.
±2.0
±1.0
Max.
±4.0
±3.0
±1.2
±15
±10
150
Units
VDC
Internal Capacitor
mW
Units
%
%
%/%
%
%
mV P - P
%
%/ºC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, 5V Input
Load Regulation, 12V Input
Ripple & Noise (20 MHz) (Note 1)
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
Parameter
RoHS Compliant
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Case Size
Case Material
Weight
1.27 x 0.62 x 0.40 Inches (32.3 x 15.7 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.42 Oz (12g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
3.5
Typ.
Max.
Units
MHours
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Conditions
5 VDC Input
12 VDC Input
1.5 mm From Case For 10 Sec.
All Models
Min.
-0.7
-0.7
Typ.
Max.
7.5
15.0
300
1,500
Units
VDC
ºC
mW
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Model
Number
A101EHI
A102EHI
A103EHI
A104EHI
A105EHI
A106EHI
A107EHI
A108EHI
A111EHI
A112EHI
A113EHI
A114EHI
A115EHI
A116EHI
A117EHI
A118EHI
Voltage (VDC)
Nominal
5
5
5
5
5
5
5
5
12
12
12
12
12
12
12
12
Range
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
Current (mA)
Full-Load
277
256
247
250
277
267
256
256
111
104
103
105
114
111
105
105
No-Load
60
60
60
60
60
60
60
60
40
40
40
40
40
40
40
40
Voltage
(VDC)
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
Output
Current
(mA, Max)
200
111
84
67
±100
±56
±42
±33
200
111
84
67
±100
±56
±42
±33
Current
(mA, Min)
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
Efficiency
(%, Typ)
72
78
81
80
72
75
78
78
75
80
81
79
73
75
79
79
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
250
250
250
250
250
250
250
250
Notes:
1. Output load regulation is specified for a load change of 10%
to 100%.
2. These units should not be operated with a load under 10%
of full load. Operation at no-load may cause damage to the
unit.
3. These converters will operate without external components.
However, when measuring output ripple, it is recommended
that an external ceramic capacitor be placed from the
+Vout pin to the -Vout pin for single output units and from
each output to
Input
Output
common for dual
Vin
Vout
Capacitor
Capacitor
output units. An
input capacitor 5 VDC
4.7
μF
5 VDC
4.7
μF
will enhance sta-
12 VDC
2.2
μF
9 VDC
2.2
μF
bility over tem-
1.0
μF
perature and input line variations. 12 VDC
Recommended capacitor values are 15 VDC
0.47
μF
given in the table above. For applica-
tions requiring very low output noise levels, a simple LC filter
should be effective.
4. Dual output units may be connected to provide a 10V, 18V,
24V or 30 VDC output. To do this, connect the load across
the positive (+Vout) and negative (-Vout) outputs and float
the output common
5. It is recommended that a fuse be used on the input of a
power supply for protection. See the Model Selection table
above for the correct rating.
Mechanical Dimensions
Derating Curve
Mechanical Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.01 (±0.25)
•
All pins are on a 0.1 (2.54) pitch
•
All pins diameters are 0.02 (0.5)
Pin Connections
Pin
1
2
8, 17
Single
+Vin
-Vin
NC
Dual
+Vin
-Vin
-Vout
Pin
10, 15
12, 13
Single
-Vout
+Vout
Dual
Common
+Vout
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com