D200ED
Series
Very Low Cost, 2W SIP
Dual Isolated Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
•
2W Output Power
•
Miniature SIP Case
•
UL Approved
(File E245422)
•
Dual Isolated Outputs
•
1,000 VDC Isolation
•
>3.5 MHour MTBF
•
12 Standard Models
•
Industry Standard Pin-Out
•
LOWEST COST!!
Parameter
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Min.
4.5
10.8
21.6
Typ.
5.0
12.0
24.0
Max.
5.5
13.2
26.4
0.3
Units
VDC
Internal Capacitor
A
Units
%
%
150
250
±0.02
mV P - P
mV P - P
%
±0.01
Momentary (0.5 Sec.)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
1,000
60
70
Conditions
Ambient
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Max.
+85
+125
Typ.
Max.
Units
VDC
VDC
MΩ
pF
kHz
Units
ºC
ºC
%/ºC
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
For Vin Change of 1%
Iout = 10% to 100%
See Note 2
See Note 2
120
Conditions
Min.
Typ.
±3.0
±1.2
±15.0
75
150
Max.
General
RoHS Compliant
Parameter
Isolation Voltage, Input/Output
Isolation Voltage, Output/Output
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Case Size
Case Material
Weight
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
0.77 x 0.28 x 0.39 Inches (19.6 x 7.0 x 10.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.09 Oz (2.8g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
3.5
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
450
ºC
mW
VDC
Typ.
Max.
Units
MHours
Units
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D201ED
D202ED
D203ED
D204ED
D211ED
D212ED
D213ED
D214ED
D221ED
D222ED
D223ED
D224ED
Input
Voltage (VDC)
Nominal
Range
Output 1
Current (mA)
Voltage
(VDC)
Output 2
Current
(mA, Min)
Current
(mA, Max)
Voltage
(VDC)
Current
(mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
80
82
82
83
80
83
85
83
81
82
84
84
Full-Load
No-Load
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
500
500
500
500
250
250
250
250
5
5
5
5
12
12
12
12
24
24
24
24
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
500
487
487
481
208
201
196
201
102
101
99
99
30
30
30
30
12
12
12
12
7
7
7
7
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
200.0
112.0
83.0
67.0
200.0
112.0
83.0
67.0
200.0
112.0
83.0
67.0
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
200.0
112.0
83.0
67.0
200.0
112.0
83.0
67.0
200.0
112.0
83.0
67.0
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
20.0
12.0
9.0
7.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external ceramic
capacitor (approx approx 1
µF
to 10
µF)
be placed from each output to
common.
3. These units should not be operated with a load under 10% of full load.
Operation at no-load may cause damage to the unit.
4. These converters are specified for operation without external components.
However, in some applications the addition of input/ouput capacitors will
enhance stability and reduce output ripple. Recommended capacitor values
are:
Block Diagram
Vin
5 VDC
12 VDC
24 VDC
Input
Capacitor
4.7
µ
F
2.2
µ
F
1.0
µ
F
Vout
5 VDC
9 VDC
12 VDC
15 VDC
Output
Capacitor
4.7
µ
F
2.2
µ
F
1.0
µ
F
0.47
µ
F
For applications requiring very low output noise levels, a simple LC filter
should be effective.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Derating Curve
g
Mechanical Dimensions
Pin Connections
Pin
1
2
4
5
6
7
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.01 (
±
0.25)
•
Pin 1 is marked by a “dot” or indentation on the side of the unit
Function
+Vin
-Vin
-Vout 1
+Vout 1
-Vout 2
+Vout 2
MicroPower Direct
www.micropowerdirect.com
•
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com