EEWORLDEEWORLDEEWORLD

Part Number

Search

56.44.8.110.43540

Description
Electromechanical Relay, 4PDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.44.8.110.43540 Overview

Electromechanical Relay, 4PDT, AC/DC Output

56.44.8.110.43540 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (AC)88 V
Coil resistance1900 Ω
Maximum coil voltage (AC)121 V
Nominal coil voltage110 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Tin Oxide
Number of terminals14
operating hours10 ms
PCB hole count14
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
2009 Overall Evaluation
[i=s] This post was last edited by paulhyde on 2014-9-15 08:56 [/i] 2009 Overall Review...
ahshan Electronics Design Contest
EEWORLD University Hall----Designing low-power AC-DC power supplies with ultra-high power density
Designing low-power AC-DC power supplies with ultra-high power density : https://training.eeworld.com.cn/course/4454...
hi5 Talking
Altium Designer 21.6.1 7 days of sharing
Link: https://pan.baidu.com/s/1KMVjYj-0Yk7l9Wsv0BMWNw Extraction code: i87f Copy this content and open the Baidu Netdisk mobile app for easier operation...
Havocbaby PCB Design
How to import CAD files *.dxf/dwg into Altium Designer to make PCB files
Is there any master who can teach me{:1_146:}...
怀土小人 PCB Design
Is there anyone who uses AVR to control the USB chip PDIUSBD12 for data transmission?
Is there anyone who uses AVR to control the USB chip PDIUSBD12 for data transmission? I am going to do a project on data transmission between AVR16 and PC recently. Have you ever adjusted the USB? The...
jjkwz MCU
Analyze LED lighting trends, let's talk about it
What is the trend of LED efficiency? Looking at the luminous efficiency of various light sources, incandescent lamps and halogen lamps are only 20~30lm/W, energy-saving bulbs are about 70lm/W, HID can...
探路者 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2095  38  866  736  721  43  1  18  15  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号