EEWORLDEEWORLDEEWORLD

Part Number

Search

TR2/SFT5

Description
Fuse,
CategoryCircuit protection    Circuit protection   
File Size75KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

TR2/SFT5 Overview

Fuse,

TR2/SFT5 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
Base Number Matches1
Bussmann
®
SMD TRON
®
Surface Mount Fuses
For .170” x .294” (4.32mm x 7.47mm) Fuses
Time-Current Characteristic CurvesÐAverage Melt
(Full Size Curves Available)
250mA
375mA
500mA
750mA
AMPERE RATING
12.5A
1A
1.5A
2A
2.5A
3A
3.5A
5A
7A
10A
SFT
R
10
Catalog Symbol:
SFT
Characteristics:
Fast-Acting, Current-Limiting
Construction:
Solid Matrix
Dimensional Data
.29" (± .015)
.17" (± .015)
(4.32 mm) (± .006)
.12" (± .015)
(3.05 mm) (± .006)
TIME IN SECONDS
.09" (± .015)
(2.29 mm) (± .006)
(7.47 mm) (± .006)
1
BUSS
SFT
5A
125V
A123
.1
.05"
(1.27 mm)
*Packaging & Ordering Information:
SFT
Product
Symbol
Package Code
TR/
500 pcs., on a 7” reel, 16mm tape width.
TR1/
2000 pcs., on a 13” reel, 16mm tape width.
TR2/
500 pcs., on a 7” reel, 12mm tape width.
TR3/
2500 pcs., on a 13” reel, 12mm tape width.
Weight
=
.6 lbs/500
*See page 2.
(See Table)
Rated Current
1
CURRENT IN AMPERES
Time-Current Characteristics:
Rated
Current
0-10
Percent of Rating
100%
4 hrs. (min)
250%
5 sec. (max)
Electrical Characteristics
Typical Voltage
Agency**
Rated
Interrupting
Pre-arcing
Typical Total Clearing
3
Drop
2
Volts at
Approvals
Rated
Voltage
Rating
1
I
2
T (A
2
sec)
I
2
T (A
2
sec)
100% Rated
5
Current
AC (Max.)
DC (Max.)
AC
DC
AC
DC
AC
DC
Current
63mA
125V
125V
50A
300A
125mA
125V
125V
50A
300A
250mA
125V
125V
50A
300A
7.49 x 10
-5
5.1 x 10
-6
2.0 x 10
-4
6.29 x 10
-6
.8
375mA
125V
125V
50A
300A
3.17 x 10
-4
2.18 x 10
-5
4.18 x 10
-4
2.67 x 10
-5
.75
500mA
125V
125V
50A
300A
4.46 x 10
-4
3.8 x 10
-5
5.74 x 10
-4
4.63 x 10
-5
.66
750mA
125V
125V
50A
300A
1.72 x 10
-3
2.27 x 10
-4
2.59 x 10
-3
2.77 x 10
-4
.525
1
125V
125V
50A
300A
.0099
.0069
.0114
.0076
.12
1.5
125V
125V
50A
300A
.0302
.0204
.0345
.0246
.20
2
125V
125V
50A
300A
.0784
.0651
.0891
.0811
.170
2.5
125V
125V
50A
300A
.1775
.1390
.2383
.1574
.145
3
125V
125V
50A
300A
.3355
.2419
.4359
.2664
.130
3.5
125V
125V
50A
300A
.4980
.3812
.6355
.4696
.155
4
125V
125V
50A
300A
.8855
.6785
1.0740
.7829
.135
5
125V
125V
50A
300A
1.7264
1.2912
2.3779
1.3556
.125
7.0A
60V
90V
50A
300A
1.64
.518
1.97
.573
.114
10.0A
60V
90V
50A
300A
3.79
1.06
3.92
1.67
.130
12.5A
48V
60V
50A
300A
15
4.04
20
4.28
.090
**Approvals: UL Recognition, Std. 248-14, Guide #JDYX2, File #E19180; CSA Certification, C22.2 No. 248.14, Class #1422-01, File #53787.
NOTE: SFT 12.5A is UL recognized on AC Only.
1. Interrupting ratings were measured at 100% power factor on AC, and a time constant less than 1ms on DC.
2. Voltage drop was measured at 25°C ± 3°C ambient temperature at rated current with device mounted on a circuit trace.
3. I
2
t measured at 50 amp, 125 VAC, .95PF, random closing angle; 300 amps, 125 VDC, TC<1ms.
4. Electrical characteristics for 12.5 amp to be determined.
5. Device designed to carry 125% of rated current for one hour minimum. An operating current of 80% or less of rated current is recommended, with further derating
required at elevated ambient temperatures.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
U.R.
CSA
10
.01
12-28-98
SB98107
Rev. A
Form No. SFT
Page 1 of 2
BIF Doc #2005
A brief analysis of BlueNRG-1's low power mode
[i=s]This post was last edited by cruelfox on 2018-1-29 15:42[/i] After playing with STEVAL-IDB007V1, I basically understand its low-power mode. There is still a big difference between this SoC and ST...
cruelfox ST - Low Power RF
Android speech emotion recognition
First, we need a background recognition model, collect voice through the client, that is, the Android side, call the background recognition module, and return the emotion classification result. Is the...
chen123asd Industrial Control Electronics
Application of UPS in communication system
With the rapid development of electronic technology , computer technology is changing with each passing day , and more and more communication equipment and computers are integrated together . These co...
frozenviolet RF/Wirelessly
The universal MATLAB
I saw a post a few days ago, so I’d like to share it with you [color=#ED1C24] Let me tell you some weird uses of matlab that you don’t know about! ! ! ! ! ! [/color] [list=1] [*][color=#ED1C24]matlab ...
白丁 FPGA/CPLD
I'm begging for the basis for selecting the pressure sensor amplifier and eddy current sensor?
RSS01 pressure sensor AD620 amplifier TR-IN01 eddy current sensor parameters...
慕诗客 51mcu
What is input bias current?
The operational amplifier is a transistor amplifier integrated on a chip. The bias current is the base DC current of the first-stage amplifier input transistor. This current ensures that the amplifier...
Jacktang Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 574  2925  2278  885  410  12  59  46  18  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号