712-475
Composite Conduit Bulkhead Feed-Through Adapter
for Environmental or Non-Environmental
Series 74 PEEK or Standard Tubing
712 475 XM 20 D E K
Product Series
Basic Number
Finish (Table II)
Dash No. (Table I)
D = D Hole Mounting Flats
N = None
E = Environmental Gland Seal Style
(Omit for Standard Non-Environmental
Style)
Add Letter K for Adapter to
accommodate PEEK Conduit
Panel
Cut-Out
D
.500
(12.7)
Ref
Typ
G
C Typ
.125 (3.2)
Max Panel
thickness Typ
F
Style E
Environmenal
See Part Number
Development
2.130 (54.1)
Max
1.410
(35.8) Max
Gland Seal
range
Tubing shown for
reference only
See Note 2
Tubing I.D. E
A Thread
.190
(4.8)
Typ
Knurl or Flute Style
Manufacurer's Option, Typ.
Non-Environmental
(See Part Number
Development)
Table I
Dash
No.
06
09
10
12
14
16
20
24
28
32
40
48
56
64
A Thread
Class 2A
M16 x 1.0
M16 x 1.0
M16 x 1.0
M16 x 1.0
M20 x 1.0
M20 x 1.0
M27 x 1.0
1-20 UNEF
M27 x 1.0
M36 x 1.0
1 1/2 -18 UNEF
1 3/4 -18 UNEF
2 -18 UNS
2 1/4 -16 UN
B
+.015 (0.4)
-.000 (0.0)
.640 (16.3)
.640 (16.3)
.640 (16.3)
.640 (16.3)
.802 (20.4)
.802 (20.4)
1.078 (27.4)
1.005 (25.5)
1.078 (27.4)
1.437 (36.5)
1.505 (38.2)
1.755 (44.6)
2.005 (50.9)
2.255 (57.3)
C
Across
Flats
.875 (22.2)
.875 (22.2)
.875 (22.2)
.875 (22.2)
1.062 (27.0)
1.062 (27.0)
1.312 (33.3)
1.312 (33.3)
1.312 (33.3)
1.750 (44.5)
1.750 (44.5)
2.000 (50.8)
2.250 (57.2)
2.500 (63.5)
D
+.000 (0.0)
-.015 (0.4)
.595 (15.1)
.595 (15.1)
.595 (15.1)
.595 (15.1)
1.752 (44.5)
1.752 (44.5)
1.069 (27.2)
.937 (23.8)
1.029 (26.1)
1.403 (35.6)
1.437 (36.5)
1.687 (42.8)
1.937 (49.2)
2.187 (55.5)
E
Max
.500 (12.7)
.600 (15.2)
.630 (16.0)
.700 (17.8)
.760 (19.3)
.850 (21.6)
.970 (24.6)
1.140 (29.0)
1.280 (32.5)
1.450 (36.8)
1.760 (44.7)
2.060 (52.3)
2.390 (60.7)
2.570 (65.3)
F
Min
.162 (4.1)
.244 (6.2)
.274 (7.0)
.326 (8.3)
.382 (9.7)
.434 (11.0)
.539 (13.7)
.649 (16.5)
.769 (19.5)
.868 (22.0)
1.078 (27.4)
1.200 (30.5)
1.400 (35.6)
1.600 (40.6)
G
Max
1.020 (25.9)
1.020 (25.9)
1.020 (25.9)
1.020 (25.9)
1.180 (30.0)
1.180 (30.0)
1.450 (36.8)
1.390 (35.3)
1.450 (36.8)
1.810 (46.0)
1.890 (48.0)
2.140 (54.4)
2.390 (60.7)
2.640 (67.1)
Tubing I.D.
Min
Max
.181 (4.6)
.273 (6.9)
.306 (7.8)
.364 (9.2)
.427 (10.8)
.485 (12.3)
.608 (15.4)
.730 (18.5)
.860 (21.8)
.187 (4.7)
.281 (7.1)
.312 (7.9)
.375 (9.5)
.437 (11.1)
.500 (1.3)
.625 (15.9)
.750 (19.1)
.875 (22.2)
Gland Seal Range
Min
Max
.156 (4.0)
.156 (4.0)
.156 (4.0)
.188 (4.8)
.250 (6.4)
.250 (6.4)
.375 (9.5)
.375 (9.5)
.438 (11.1)
.625 (15.9)
.250 (6.4)
.250 (6.4)
.250 (6.4)
.312 (7.9)
.438 (11.1)
.438 (11.1)
.625 (15.9)
.625 (15.9)
.750 (19.1)
.938 (23.8)
.975 (24.8) 1.000 (25.4)
1.210 (30.7) 1.250 (31.8)
.875 (22.2) 1.250 (31.8)
1.437 (36.5) 1.500 (38.1) 1.000 (25.4) 1.375 (34.9)
1.688 (42.9) 1.750 (44.5) 1.250 (31.8) 1.625 (41.3)
2.937 (74.6) 2.000 (50.8) 1.250 (31.8) 1.625 (41.3)
Table II
TABLE 2
XM
XW
XB
XO
Electroless Nickel
Cadmium Olive Drab Over Electroless
Nickel
No Plating - Black Material
No Plating - Base Material
Non-conductive
NOTES:
1.
Metric dimensions (mm) are in parentheses and are for reference only.
2.
Convoluted tubing size, tubing to be ordered separately (See Page I-23).
© 2003 Glenair, Inc.
CAGE Codes 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
D-33
Series 74