Switching Spark Gap
CAS02X-047
Ordering code:
B88069X0470T502
DC spark-over voltage
1) 2)
Initial values
Ignition time t
I
after 150 hours in darkness
3)
at –20 °C
at +25; 125 °C
Electrical life time
Maximum increase of DC spark-over voltage
Switching operations at +25; 125 °C
Switching frequency 10 … 25 Hz
Switching frequency < 10Hz
Test circuit parameters
Open circuit voltage V
0'
Loading resistance R
Discharge capacitance C
Inductance L
Discharge peak current I
P
Insulation resistance at 100 V
dc
Capacitance at 1 MHz
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, red
215 ... 240
V
95
≤
4
≤
2
25
2 000 000
4 000 000
230
15
2.2
10
~ 300
> 0.1
<2
~ 1.5
99.9
≤
5
≤
3
100
≤
7
≤
4
%
s
s
V
Ignitions
Ignitions
V
ac
kΩ
µF
µH
A
GΩ
pF
g
°C
-20 ... +125
20/ 125/ 21
CS 230 YYMM O
CS
230
YY
MM
O
- Series
- Nominal voltage
- Year of production
- Month of production
- Non radioactive
1)
2)
3)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode, after load
Time from capacitor charged to the first high voltage spark
Test circuit: V
ac
= 198 V; R = 36 kΩ; C = 2.2 µF
AB E / AB PM
Page 1 of 2
Issue 04, 10.02.2004
Switching Spark Gap
CAS02X-047
Ordering code:
B88069X0470T502
Not to scale
Dimensions in mm
Non controlled document
EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and
Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless
otherwise agreed.
AB E / AB PM
Page 2 of 2
Issue 04, 10.02.2004