Switching Spark Gap
Preliminary data
CAS04XG
Ordering code:
B88069X1200T502
DC spark-over voltage
1) 2)
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs
- for 99 % of measured values
- typical values of distribution
350 ... 550
V
< 900
< 800
< 1200
< 1100
>1
<1
1000
>1
270 ... 650
~ 10
< 100
~ 60
~ 1.5
-40 ... +90
40/ 90/ 21
400 YYMM O
CS
400
YY
MM
O
- Series
- Nominal voltage
- Year of production
- Month of production
- Non radioactive
V
V
V
V
G
Ω
pF
h
G
Ω
V
V
A
V
g
°C
Insulation resistance at 300 V
dc
Capacitance at 1 MHz
Service life in customer circuit
Unit must meet
Insulation resistance
DC spark-over voltage
after 250, 500, 750 and 1000 h
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, red
1)
2)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM
Page 1 of 2
Issue 03, 30.04.2002
Switching Spark Gap
Preliminary data
CAS04XG
Ordering code:
B88069X1200T502
Not to scale
Dimensions in mm
Non controlled document
EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and
Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless
otherwise agreed.
AB E / AB PM
Page 2 of 2
Issue 03, 30.04.2002