EEWORLDEEWORLDEEWORLD

Part Number

Search

HPS10R-A5N-032

Description
HPS10/12/15 Series
File Size1MB,5 Pages
ManufacturerVertiv
Download Datasheet View All

HPS10R-A5N-032 Overview

HPS10/12/15 Series

1000-6000 Watts
HPS10/12/15 Series
Electrical Specs
Input
Input voltage
Frequency
Inrush current
Efficiency
Power factor
Turn-on time
85-264 VAC*
47-440 Hz
40 A peak max.
85% typ @ full case load 230 VAC
0.99 typical meets EN61000-3-2
AC on 1.5 sec. typical, Inhibit /
Enable 100 ms typical
CISPR 22 EN55022 Level “B”
2 mA max @ 264 VAC @ 60Hz
(per module)
CISPR 22 EN55022 Level “B”
20 ms minimum
(independent of input VAC)
>5 ms early warning min. before
outputs lose regulation; Full cycle
ride thru (50 Hz)
Meets EN61000-3-2
Meets EN60950
Special Features
Integrated OR-ing diode
Remote Sense on Bulk output
Overload protection on all outputs
Active Inrush limiting
PFC to 0.99 typical EN61000-3-2
CISPR22, EN55022 Curve B
conducted/radiated EMI
EN61000 immunity standards
Optional 48 W fan voltage (12 V or 24 V)
Standard 5 V at 5 A standby voltage (3.3V option)
No minimum load
Overvoltage protection
Input OK signal and indicator LED
Inhibit/Enable
Remote Margin/Voltage Programming
Optional current monitor
Optional AC Line discrimination
Output Good signal and indicator LED
Temp good signal and indicator LED
Optional single wire digital temp monitor
2
Optional module I C interface
Optional Rack µController
Hot Plug
N+1 Redundant Standard
Optional fan fail signal
Module present signal
Optional short circut latch
EMI filter standard
Leakage current standard
Radiated EMI
Holdup time
AC OK
Harmonic distortion
Isolation
* see modules table on the next page
Output
Margining
Overall reg
Ripple
Dynamic response
Recovery time
Overcurrent protection
Short circuit protection
Overvoltage protection
Reverse voltage
protection
Thermal protection
Remote sense
Single wire parallel
DC OK
Minimum load
Standby voltage
Global Inhibit/Enable
±5% of nominal
1%
1% of Vout Pk-Pk limited to 20 MHz
2% with 25% load step
To within 1% in <300 µsec
105-120% of rated output current
Protected for continuous short
circuit. Recovery is automatic upon
removal of short
105-120% . Recycle AC input voltage
to reset OVP circuit
100% of rated output current
Main and Aux disabled when internal
temp exceeds safe operating range.
Up to 0.5 V total drop
Current share to within 10% of total
rated current
±5% of nominal
Not required
5 VDC @5A max. present whenever
AC input is applied (3.3 V @ 5A
optional)
Logic “0” standard logic “1” optional
Environmental & Safety
Operating temperature: -10°C to +50°C ambient,
derate output @ 2.5% per degree from 50°C to 70°C
Shock/Vibration: Mil-Hdbk 810E
Humidity: 95% non-condensing
Storage temperature: -40°C to +85°C
Temperature coefficient: 0.02% per °C
Cooling: Internal DC fan
MTBF (Calculated): 200 KHrs; 25°C, 200 VAC input,
nominal O/P voltage, full load
Safety:
UL / CSA
UL60950 3
rd
Ed and CSA C22.2 60950
TUV
EN60950
CB
Certificate and report
CE
Mark
152
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 08.25.04
How to quickly design an infrared body temperature detector?
Temperature detection is a necessary monitoring system for us at home, in and out of the community or workplace, and when traveling. Infrared thermometers help reduce contact transmission through non-...
Jacktang Microcontroller MCU
Analysis of the market environment of PCB for MP4
1. Domestic development of MP4: promising prospects, but the market is scattered CBIResearch predicts that in the second half of 2006, China's MP4 player output will reach 497,000 units, 775,000 units...
songbo PCB Design
Famous quotes about overcoming setbacks
1. One of the great advantages of outstanding people is that they never give up in the face of adversity and hardship. --Beethoven 2. Every setback or adverse mutation carries the same or greater favo...
sijialgc Talking about work
[Code Download] AD7760 Code
...
dontium ADI Reference Circuit
The servo motor control system often fails to reach zero position when returning to the electrical origin, resulting in machine failure. How to deal with it?
The origin should be zero, but it often stops at 0.05 or 0.03 and cannot reach the original position. What is the reason? The machine also stops and sometimes there is no alarm. Is it the encoder or t...
eeleader-mcu Industrial Control Electronics
Could you please help me analyze why Wince5.0 crashes after running for more than 100 hours?
I wrote a program on Wince5.0 using evc. It crashed after running for 2 hours at first. I wrote delete in all the new places. But now it crashed again after running for more than 100 hours. I wrote de...
cqk62 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2169  2391  2867  1275  2744  44  49  58  26  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号