OM1905N2M
OM1912N2M
OM1915N2M
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWING
LCC 20, Fixed Voltage, Precision
Negative Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
DESCRIPTION
These negative regulators are supplied in a hermetically sealed surface mount pack-
age. All protective features are designed into the circuit including thermal shutdown,
current limiting and safe-area control. With heat sinking, they can deliver over .5 amps
of output current. These units feature internally trimmed output voltages to ±1% of
nominal voltage. Standard voltages are -5V, -12V, and -15V. These units are ideally
suited for Military applications where a hermetic surface mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8874601 2X
5962-8874701 2X
5962-8874801 2X
Omnirel Part Number
OM1905N2M
OM1912N2M
OM1915N2M
3.5
4 11 R0
3.5 - 1
2
OM1905N2M - OM1915N2M
ABSOLUTE MAXIMUM RATINGS
@ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V Operating
Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C Storage
Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C Typical
Power/Thermal Charateristics:
Rated Power @ 25° C
T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040 mW
Thermal Resistance
θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25°C/W
θ
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
ELECTRICAL CHARACTERISTICS -5
Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -10V, I
o
= 100mA, -55°C
≤
T
A
≤
125°C (unless otherwise specified)
Min.
-4.95
Max.
-5.05
-5.15
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -7.5V to -20V
I
O
= 5 mA to 500 mA, P < 2W
•
-4.85
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -7.5V to -20V
12
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -8.0V to -12V
25
5
•
Load Regulation
(Note 1)
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
∆V
OUT
∆t
T
A
= 25°C, t = 1000 hrs.
N
O
∆V
OUT
= 100mV, I
O
=
500 mA
T
A
= 25°C
V
IN
= -35V
I
O
= 5mA to 500 mA
V
IN
= -7.0V to -20V
V
RLOAD
I
O
= 5mA to 500 mA
12
25
•
•
•
•
•
0.5
50
2.5
3.0
0.4
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
0.4
mA
2.5
1.7
.7
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
63
2.0
•
60
40
µV/V
RMS
75
mV
3.5
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5 - 2
OM1905N2M - OM1915N2M
ELECTRICAL CHARACTERISTICS -12 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -19V, I
o
= 100 mA, -55°C
≤
T
A
≤
125°C (unless otherwise specified)
Min.
-11.88
Max.
-12.12
-12.36
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -14.5V to -27V
I
O
= 5mA to 500 mA, P
D
< 2 W
•
-11.64
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -14.5V to -27V
20
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -16V to -22V
50
10
•
Load Regulation
(Note 1)
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
∆V
OUT
∆t
T
A
= 25°C, t = 1000 hrs.
N
O
∆V
OUT
= 100mV, I
O
=
500 mA
T
A
= 25°C, I
O
= 5 mA to 1A
V
IN
= -35V
I
O
= 5mA to 500 mA
V
IN
= -14.5V to -27V
V
RLOAD
I
O
= 5 mA to 500 mA
30
32
•
•
•
•
•
0.5
60
3.5
4.0
0.8
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
0.5
mA
1.8
1.7
.7
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100 KHz
56
2.0
•
53
40
µV/V
RMS
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
PIN CONNECTION
Terminal Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
NC
V
INput
NC
V
OUTput
V
OUTput
NC
V
OUTput
NC
NC
NC
NC
NC
NC
NC
Ground
NC
Ground
NC
NC
V
INput
.003
MECHANICAL OUTLINE
.009 R.
20 PLCS.
.020 X45°
REF.
(±.003)
.065
.040
4
.010
.075
(±.010)
TYP.
9
3.5
.025
TYP.
.085
3
1
19
.160
SQ. REF.
13
18
14
Note: The input pins (2 and 20) are to be connected
together, the output pins (4,5, and 7) are to be con-
nected together and the ground pins (15 and 17) are
to be connected together for operation.
.025 SQ.
TYP.
.050
TYP.
.040 X45°
REF (3 PL)
2
.050
(±.005)
TYP.
3.5 - 3
OM1905N2M - OM1915N2M
ELECTRICAL CHARACTERISTICS -15 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -23V, I
o
= 100mA, -55°C
≤
T
A
≤
125°C (unless otherwise specified)
Min.
-14.85
Max.
-15.15
-15.45
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -17.5V to -30V
I
O
= 5 mA to 500 m A, P
D
< 2 W
•
-14.55
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -17.5V to -30V
25
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -20V to -26V
50
15
•
Load Regulation
(Note 1)
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
∆V
OUT
∆t
T
A
= 25°C, t = 1000 hrs.
N
O
∆V
OUT
= 100mV, I
O
=
500 mA
T
A
= 25°C
V
IN
= -35V
I
O
= 5mA to 500 mA
V
IN
= -17.5V to -30V
V
RLOAD
I
O
= 5mA to 500 mA
25
50
•
•
•
•
•
0.5
90
6.0
6.5
0.8
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
0.5
mA
2.5
1.7
0.7
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
53
2.0
•
50
40
µV/V
RMS
150
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5
205 Crawford Street, Leominster, MA 01453 USA (978) 534-5776 FAX (978) 537-4246
Vi it O W b Sit t
i l