EEWORLDEEWORLDEEWORLD

Part Number

Search

31001112

Description
Modular Terminal Block,
CategoryThe connector    terminals   
File Size103KB,1 Pages
ManufacturerMETZ CONNECT
Websitehttp://www.metz-connect.com/
Environmental Compliance
Download Datasheet Parametric View All

31001112 Overview

Modular Terminal Block,

31001112 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Terminal and terminal strip typesMODULAR TERMINAL BLOCK
Base Number Matches1
65
Note for wire range
Additional wire sizes and/or
combinations of same size
wires as follows:
Type 01
and
Type 55
#(1) Wire range extended
to No. 30 AWG for
factory-wiring
++
Two same size wires
No. 22 - 18 AWG Cu
Sol/Str for field-wiring;
30 - 18 AWG Cu
Sol/Str factory-wiring
Type 001
Screw type terminal block, solderable, centerline 5 mm /
0.197 inches, horizontal wire entry, wire protector
Type 055
Screw type terminal block, solderable, centerline 5 mm /
0.197 inches, horizontal wire entry, wire protector,
modular
A
Technical Data
V / A / AWG
V / A / AWG
300 / 15 / 22 - 14
300 / 15 / 22 - 14
Technical Data
V / A / AWG
V / A / AWG
300 / 15 / 22 - 14
300 / 15 / 22 - 14
0.33 - 1.5 mm² 125 V / 2.5 kV / 13 A
Insulation co-ordination according to EN 60664-1
Clearance and creepage distances min. 2.6 mm
Insulating material class
CTI 600
Overvoltage category
III
III
II
Pollution degree
3
2
2
Rated voltage
200
500
500
Rated test voltage
2.5
4
2.5
Protection category according
to IEC 529
IP00
Tightening torque UL
4.4 lb-in max.
Min. insul. strip length
6 mm
Solder pin dimension
0.9 mm
Recommended pc board hole
dia.
Ø 1.3 mm
Solder pin length
3.8 mm
Pole size
2 - 22
Color
grey
Dimensions in mm
1 mm = 0.0394 in.
0.33 - 1.5 mm² 125 V / 2.5 kV / 13 A
Insulation co-ordination according to EN 60664-1
Clearance and creepage distances min. 2.6 mm
Insulating material class
CTI 600
Overvoltage category
III
III
II
Pollution degree
3
2
2
Rated voltage
200
500
500
Rated test voltage
2.5
4
2.5
Protection category according
to IEC 529
IP00
Tightening torque UL
4.4 lb-in max.
Min. insul. strip length
6 mm
Solder pin dimension
0.9 mm
Recommended pc board hole
dia.
Ø 1.3 mm
Solder pin length
3.8 mm
Pole size
2-4
Color
grey
Dimensions in mm
1 mm = 0.0394 in.
L = (pole size - 1) x centerline + 5 mm / 0.197 inches
L = (pole size - 1) x centerline + 5 mm / 0.197 inches
Part numbers (P/N)
Type 001
centerline 5 mm / 0.197 inches
(information: page 56)
Complete the part number by
adding the pole size.
Part numbers (P/N)
Type 055
(information: page 56)
Complete the part number by
adding the pole size.
02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
17 18 19 20 21 22
centerline 5 mm / 0.197 inches
02 03 04
P/N
310011
Type 001
centerline 10 mm / 0.394 inches
P/N
310551
02 03 04 05 06 07 08
09 10 11
P/N
310012
Standard pole sizes
Available on demand. Minimum order quantity 5000
pieces per item.
Standard pole sizes
Available on demand. Minimum order quantity 5000
pieces per item.
Sampling rate of MCU ADC
For example, if the sampling rate of the MCU ADC is 200KSPS, is it equal to 200KHZ? Does it mean 200K samples per second? If the crystal oscillator is 11.0592MZ, how to determine whether the clock fre...
QWE4562009 Test/Measurement
[Shenjing] Open source my multi-functional debugging tool: UsbHub+xlink+USB to serial port/485/Nrf24L01/infrared
I was really envious of Ma Ge’s multi-function debugging tool, so I also made a high-speed USB hub and supported an xlink, and used stm32 to realize USB to serial TTL/serial 232/serial 485 (through ju...
sblpp stm32/stm8
May I ask in which function of the system is the clock displayed in the wince system tray (for example, 12:00) implemented?
As the title says, if I click on the clock in the tray to change the time, what registry entry will be modified accordingly? Please give me some advice!...
meiwenbin Embedded System
Oscillation wave immunity test solution-EMS test system
[p=null, 2, left]This test simulates the repetitive damped oscillatory waves that appear in the power cables, control cables and signal cables installed in high-voltage and medium-voltage substations,...
bjhyyq Industrial Control Electronics
[Sipeed LicheeRV 86 Panel Review] 7-Waft Graphical Interface Development Test (Part 2)
In the previous article, the Waft test routine has been compiled. When updating the binary library file, the problem of insufficient system capacity is encountered. In this article, we will first expa...
DDZZ669 Domestic Chip Exchange
China Netcom is gone, the Olympic sponsors' money wasted~
China Netcom: Building a Broadband Olympics "Network connects the world, broadband fulfills dreams" is China Netcom's brand appeal. On July 22, 2004, China Netcom officially became the fixed communica...
yuyj RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development