General-purpose Relay
LY
A Miniature Power Relay
• Equipped with arc barrier.
• Dielectric strength: 2,000 V.
• Built-in diode models added to the LY Series.
• Single-pole and double-pole models are applicable to operating
coils with ratings of 100/110 VAC, 110/120 VAC, 200/220 VAC,
220/240 VAC, or 100/110 VDC).
• Three-pole and four-pole models are applicable to operating
coils with ratings of 100/110 VAC, 200/220 VAC, or 100/110
VDC).
LR
Ordering Information
■
Open Relays
Type
Contact form
Plug-in/solder
terminals
Plug-in/solder
terminals with LED
indicator
PCB terminals
Upper-mounting
Plug-in/solder
terminals
Standard
SPDT
DPDT
DPDT (bifurcated)
3PDT
4PDT
LY1
LY2
LY2Z
LY3
LY4
LY1-D
LY2-D
LY2Z-D
LY3-D
LY4-D
---
LY2-CR
LY2Z-CR
LY1N
LY2N
LY2ZN
LY3N
LY4N
LY1N-D2
LY2N-D2
LY2ZN-D2
---
LY4N-D2
---
LY2N-CR
LY2ZN-CR
LY1-0
LY2-0
LY2Z-0
LY3-0
LY4-0
---
---
---
---
---
---
---
---
LY1F
LY2F
LY2ZF
LY3F
LY4F
---
---
---
---
---
---
---
---
With built-in diode
(DC only)
SPDT
DPDT
DPDT (bifurcated)
3PDT
4PDT
With built-in CR
(AC only)
SPDT
DPDT
DPDT (bifurcated)
Note: 1.
When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Example: LY2, 6 VAC
Rated coil voltage
2.
Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask your OMRON representative for details.
3.
SEV models are standard Relays excluding DPDT (bifurcated) models.
4.
VDE- or LR- qualifying Relays must be specified when ordering.
78
General-purpose Relay
LY
■
Accessories (Order Separately)
Sockets
Poles
1 or 2
3
4
Front-connecting Socket
DIN track/screw terminals
PTF08A-E, PTF08A
PTF11A
PTF14A-E, PTF14A
Plug-in/solder terminals
PT08
PT11
PT14
Back-connecting Socket
Wrapping terminals
PT08QN
PT11QN
PT14QN
PT08-0
PT11-0
PT14-0
PCB terminals
Note: 1.
For PTF08-E and PTF14A-E, see “Track Mounted Socket.”
2.
PTF@A (-E) Sockets have met UL and CSA standards: UL 508/CSA C22.2.
Mounting Plates for Sockets
Socket model
PT08
PT08QN
PT11
PT11QN
PT14
PT14QN
PYP-1
PTP-1-3
PTP-1
For 1 Socket
---
---
PTP-10
For 10 Sockets
---
PTP-12
---
For 12 Sockets
For 18 Sockets
PYP-18
---
---
Socket-Hold-down Clip Pairings
Relay type
Poles
Front-connecting Sockets
Socket model
Standard, bifurcated contacts oper- 1, 2
ation indicator, built-in diode
3
4
CR circuit
2
PTF08A-E, PTF08A
PTF11A
PTF14A-E, PTF14A
PTF08A-E, PTF08A
Y92H-3
Clip model
PYC-A1
Back-connecting Sockets
Socket model
PT08(QN), PT08-0
PT11(QN), PT11-0
PT14(QN), PT14-0
PT08(QN), PT08-0
PYC-1
Clip model
PYC-P
Specifications
■
Coil Ratings
Single- and Double-pole Relays
Rated voltage
Rated current
Coil
resistance
Coil inductance
(reference value)
Arm. OFF
12.2
Ω
46
Ω
180
Ω
788
Ω
3,750
Ω
4,430
Ω
12,950
Ω
18,790
Ω
40
Ω
160
Ω
650
Ω
2,600
Ω
11,000
Ω
0.04 H
0.17 H
0.69 H
3.22 H
14.54 H
19.20 H
54.75 H
83.50 H
0.16 H
0.73 H
3.20 H
10.6 H
45.6 H
Arm. ON
0.08 H
0.33 H
1.30 H
5.66 H
24.6 H
32.1 H
94.07 H
136.40 H
0.33 H
1.37 H
5.72 H
21.0 H
86.2 H
10% min.
0.9 W
0.9 to 1 VA
(60 Hz)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consum.
(approx.)
1.0 to 1.2 VA
(60 Hz)
50 Hz
AC
6V
12 V
24 V
50 V
100/110 V
110/120 V
200/220 V
220/240 V
DC
6V
12 V
24 V
48 V
100/110 V
214.1 mA
106.5 mA
53.8 mA
25.7 mA
11.7/12.9 mA
9.9/10.8 mA
6.2/6.8 mA
4.8/5.3 mA
150 mA
75 mA
36.9 mA
18.5 mA
9.1/10 mA
60 Hz
183 mA
91 mA
46 mA
22 mA
10/11 mA
8.4/9.2 mA
5.3/5.8 mA
4.2/4.6 mA
% of rated voltage
80% max. 30% min.
110%
Note:
See notes on the bottom of next page.
General-purpose Relay
LY
79
Three-pole Relays
Rated voltage
Rated current
Coil
resistance
Coil inductance
(reference value)
Arm. OFF
6.7
Ω
24
Ω
100
Ω
410
Ω
2,300
Ω
8,650
Ω
25.7
Ω
107
Ω
410
Ω
1,700
Ω
8,500
Ω
0.03 H
0.12 H
0.44 H
2.24 H
10.5 H
34.8 H
0.11 H
0.45 H
1.89 H
8.53 H
29.6 H
Arm. ON
0.05 H
0.21 H
0.79 H
3.87 H
18.5 H
59.5 H
0.21 H
0.98 H
3.87 H
13.9 H
54.3 H
10% min.
1.4 W
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consum.
(approx)
1.6 to 2.0 VA
(60 Hz)
50 Hz
AC
6V
12 V
24 V
50 V
100/110 V
200/220 V
DC
6V
12 V
24 V
48 V
100/110 V
310 mA
159 mA
80 mA
38 mA
14.1/16 mA
9.0/10.0 mA
234 mA
112 mA
58.6 mA
28.2 mA
12.7/13 mA
60 Hz
270 mA
134 mA
67 mA
33 mA
12.4/13.7 mA
7.7/8.5 mA
% of rated voltage
80% max. 30% min.
110%
Note:
See notes under next table.
Four-pole Relays
Rated voltage
Rated current
Coil
resistance
Coil inductance
(reference value)
Arm. OFF
5
Ω
20
Ω
78
Ω
350
Ω
1,600
Ω
6,700
Ω
25
Ω
100
Ω
350
Ω
1,600
Ω
6,900
Ω
0.02 H
0.10 H
0.38 H
1.74 H
10.5 H
33.1 H
0.09 H
0.39 H
1.41 H
6.39 H
32 H
Arm. ON
0.04 H
0.17 H
0.67 H
2.88 H
17.3 H
57.9 H
0.21 H
0.84 H
2.91 H
13.6 H
63.7 H
10% min.
1.5 W
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consum.
(approx)
1.95 to
2.5 VA
(60 Hz)
50 Hz
AC
6V
12 V
24 V
50 V
100/110 V
200/220 V
DC
6V
12 V
24 V
48 V
100/110 V
386 mA
199 mA
93.6 mA
46.8 mA
22.5/25.5 mA
11.5/13.1 mA
240 mA
120 mA
69 mA
30 mA
15/15.9 mA
60 Hz
330 mA
170 mA
80 mA
40 mA
19/21.8 mA
9.8/11.2 mA
% of rated voltage
80% max. 30% min.
110%
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances of +15%/–20% for rated currents and
±
15% for DC coil resistance.
2.
Performance characteristic data are measured at a coil temperatures of 23
°
C.
3.
AC coil resistance and impedance are provided as reference values (at 60 Hz).
4.
Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-
sistor if required.
80
General-purpose Relay
LY
■
Contact Ratings
Relay
1-pole
Load
Resistive load
(cos
φ
= 1)
110 VAC 15 A
24 VDC 15 A
15 A
250 VAC
125 VDC
15 A
Inductive load
(cos
φ
=0.4,
L/R=7 ms)
110 VAC 10 A
24 VDC 7 A
Single contact
2-, 3- or 4-pole
Resistive load
(cos
φ
= 1)
110 VAC 10 A
24 VDC 10 A
10 A
250 VAC
125 VDC
10 A
Inductive load
(cos
φ
=0.4,
L/R=7 ms)
110 VAC 7.5 A
24 VDC 5 A
Resistive load
(cos
φ
= 1)
110 VAC 5A
24 VDC 5 A
7A
250 VAC
125 VDC
7A
Bifurcated contacts
2-pole
Inductive load
(cos
φ
=0.4,
L/R=7 ms)
110 VAC 4 A
24 VDC 4A
Rated load
Rated carry
current
Max.
switching
voltage
Max.
switching
current
Max.
switching
power
Failure rate
(reference
value)*
1,700 VA
360 W
100 mA, 5 VDC
1,100 VA
170 W
1,100 VA
240 W
100 mA, 5 VDC
825 VA
120 W
550 VA
120 W
10 mA, 5 VDC
440 VA
100 W
*Note:
P level:
λ
60
= 0.1 x 10
-6
/operation, reference value
■
Characteristics
Item
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
All except Relays with bifurcated contacts
50 m
Ω
max.
25 ms max.
25 ms max.
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Relays with bifurcated contacts
100 M
Ω
min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
1,000 m/s
2
200 m/s
2
AC: 50,000,000 operations min. (at 18,000 operations/hr)
DC: 1,00,000,000 operations min. (at 18,000 operations/hr)
Single-, three-, and four-pole: 200,000 operations min. (at 1,800 operations/hr
under rated load)
Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature*
Operating:
Single- and double-pole standard, bifurcated-contact Relays: –25
°
C to 55
°
C (with no icing)
(–25
°
C to 70
°
C if carry current is 4 A or less)
All other Relays: –25
°
C to 40
°
C (with no icing) (–25
°
C to 55
°
C if carry current is 4 A or less)
Operating:
5% to 85%
Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g
Ambient humidity
Weight
Note: 1.
The values given above are initial values.
2.
The upper limit of 40
°
C for some Relays is because of the relationship between diode junction temperature and the element used.
General-purpose Relay
LY
81
■
Endurance Under Real Loads (reference only)
LY1
Rated voltage
100 VAC
Load type
AC motor
AC lamp
Conditions
Operating frequency
Electrical life
50,000 operations
100,000 operations
25,000 operations
100,000 operations
1,500,000 operations
800,000 operations
400 W, 100 VAC single-phase with 35-A in- ON for 10 s, OFF for 50 s
rush current, 7-A current flow
300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s
3-A current flow
500 W, 100 VAC with 78-A inrush current,
5-A current flow
Capacitor
(2,000
µ
F)
AC solenoid
24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 6 s
rent flow
50 VA with 2.5-A inrush current, 0.25-A
current flow
100 VA with 5-A inrush current, 0.5-A cur-
rent flow
ON for 1 s, OFF for 2 s
LY2
Rated voltage
100 VAC
Load type
AC motor
AC lamp
Capacitor
(2,000
µ
F)
Conditions
Operating frequency
Electrical life
200,000 operations
80,000 operations
10,000 operations
150,000 operations
ON for 1 s, OFF for 2 s
1,000,000 operations
500,000 operations
200 W, 100 VAC single-phase with 25-A in- ON for 10 s, OFF for 50 s
rush current, 5-A current flow
300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s
3-A current flow
24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 15 s
rent flow
24 VDC with 20-A inrush current, 1-A cur-
rent flow
AC solenoid
50 VA with 2.5-A inrush current, 0.25-A
current flow
100 VA with 5-A inrush current, 0.5-A cur-
rent flow
LY4
Rated voltage
100 VAC
Load type
AC motor
Conditions
200 W, 200 VAC triple-phase with 5-A in-
rush current, 1-A current flow
750 W, 200 VAC triple-phase with 18-A in-
rush current, 3.5 A current flow
AC lamp
Capacitor
(2,000
µ
F)
300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s
3-A current flow
24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 15 s
rent flow
24 VDC with 20-A inrush current, 1-A cur- ON for 1 s, OFF for 2 s
rent flow
AC solenoid
50 VA with 2.5-A inrush current, 0.25-A
current flow
100 VA with 5-A inrush current, 0.5-A cur-
rent flow
ON for 1 s, OFF for 2 s
Operating frequency
ON for 10 s, OFF for 50 s
Electrical life
500,000 operations
70,000 operations
50,000 operations
5,000 operations
200,000 operations
1,000,000 operations
500,000 operations
82
General-purpose Relay
LY