EEWORLDEEWORLDEEWORLD

Part Number

Search

31012102

Description
Modular Terminal Block,
CategoryThe connector    terminals   
File Size150KB,1 Pages
ManufacturerMETZ CONNECT
Websitehttp://www.metz-connect.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

31012102 Overview

Modular Terminal Block,

31012102 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerMETZ CONNECT
Reach Compliance Codecompliant
ECCN codeEAR99
Terminal and terminal strip typesMODULAR TERMINAL BLOCK
Base Number Matches1
mm to inch
1 inch = 25.4 mm
1 mm = .040 inches
Designed to IEC 60664-1
Designed to IEC 60664-1
Type
Type
with lift system
modular
12
Non Modular Type
similar to
Type 12
Type 11
similar to
Type 72
Type 71
Page DA-16
Page DA-16
72
300 V
15 A
12 - 22 AWG
# (see note)
8 lbs. - in
.8 mm x 1 mm
1.4 mm
7 mm
with lift system
modular
Electrical Data
Voltage
Current
Wire Range
Screw torque
Square pin
PCB hole diameter
Wire strip length
Electrical Data
Voltage
Current
Wire Range
Screw torque
Square pin
PCB hole diameter
Wire strip length
300 V
20 A
12 - 22 AWG
## (see note)
6 lbs. - in
.8 mm x 1 mm
1.4 mm
8 mm
Mechanical Data
Housing
UL 94V-0
-40 °F to 189 °F
(-40 °C to 105 °C)
brown
brass, nickel plated
brass, tin over nickel plating
M3, steel
nickel over copper plating
2 to 4
Mechanical Data
Housing
UL 94V-0
-40 °F to 189 °F
(-40 °C to 105 °C)
brown
brass, nickel plated
brass, tin over nickel plating
M3, steel
nickel over copper plating
optional: stainless steel
- consult factory
2 to 4
Color
Terminal
Lift system
Screw
Pole sizes
Color
Terminal
Lift system
Screw
Pole sizes
Additional material data - pages DA-3 to DA-5
Additional material data - pages DA-3 to DA-5
Dimensions (mm)
Dimensions (mm)
Note for wire range
Additional wire sizes and/or
combinations of same size
wires as follows:
L = (circuits - 1) x centerline + 5
L = (circuits - 1) x centerline + 5
Part Numbers
Type 12
Complete the part number
by adding the pole size.
centerline 5 mm
Part Numbers
02 03 04
Type 12
#
1 No. 30 AWG
(Factory-wiring)
2 No. 22-16 AWG
(Field-wiring);
2 No. 30-16 AWG or
1 No. 30-12 AWG
(Factory-wiring)
Part No.
310121
Type 72
Complete the part number
by adding the pole size.
centerline 5 mm
02 03 04
Part No.
310721
Type 72
##
01 standard
08 Available on demand. Minimum order
quantity 3000 poles per item.
01 standard
08 Available on demand. Minimum order
quantity 3000 poles per item.
Subject to technical changes and printing errors.
RIA electronic, Inc.
430 Industrial Way West, Eatontown, NJ 07724
phone 1-888-722-5625
fax 732-389-9066
www.riaelectronic.com
DA-19
D

31012102 Related Products

31012102 31012104 31012103
Description Modular Terminal Block, Modular Terminal Block, Modular Terminal Block,
Is it Rohs certified? conform to conform to conform to
Maker METZ CONNECT METZ CONNECT METZ CONNECT
Reach Compliance Code compliant compliant compliant
ECCN code EAR99 EAR99 EAR99
Terminal and terminal strip types MODULAR TERMINAL BLOCK MODULAR TERMINAL BLOCK MODULAR TERMINAL BLOCK
Base Number Matches 1 1 -
Swapping LPC1549 development board [Completed]
[i=s]This post was last edited by dcexpert on 2015-9-8 13:30[/i] []Does anyone have an unused LPC1549 [img]https://developer.mbed.org/media/cache/platforms/250x219xLPCXpresso1549_1.png.250x250_q85.jpg...
dcexpert Buy&Sell
How can I use vs2005 to output signals from the serial port to the microcontroller?
I would like to ask how to use vs2005 to output signals from the serial port to the microcontroller. I recently used opencv1.0 to study video recognition in vs2005, and found that I need to write a pr...
christine Embedded System
Weak circuit voltage amplification circuit diagram or module.
How to apply the weak induced current generated by cutting magnetic lines of force?...
白虹贯日7070 Power technology
FAQ: A new generation of products based on the optimized design of Melexis second-generation position sensors
Live Topic: A new generation of products based on the optimized design of Melexis second-generation position sensors, with higher performance and competitive costBrief introduction: This seminar mainl...
EEWORLD社区 Robotics Development
How to set the CAN bus receiving shield code
If I only want to receive frames with an address of 0x02 in the 11-bit address, how should I set my mask code? What is the mask code setting?...
mintmsn Embedded System
Problems with two microcontrollers communicating via simulated I2C
Now I am doing a project. Due to the limitation of 51 MCU resources, I can only communicate by simulating I2C. It is relatively simple for the host to simulate I2C, but it is a bit difficult for the s...
brain发烧友 51mcu

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2778  2279  2281  278  749  56  46  6  16  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号