Input Specifications
Parameter
Operating Range
Inrush Current Limiting
36V
D
72V
DC
Efficiency
48 V
DC
, at full load
70
25
50
A
PK
A
PK
%
Conditions
DC
Min
36
Typ
48
Max
72
Units
V
DC
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 0.7V of line drop. Remote Sense leads
are protected against open, short and reversal.
Remote On/Off (Optional)
The power supply is turned on with a TTL logic ‘1’ (or open)
signal and turned off by a switch closure or TTL logic ‘0’
referenced to (-) sense terminal. Consult the factory for
other options.
Over Voltage Protection
Output #1: 6.5V ± 0.5 V
DC.
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Active Inrush Current Limiting
Inrush current is independent of ambient temperature.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200
μsec
for a 25% load step
change.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Safety
Safety certified to UL/CUL to 1950, File Number E131694
TUV to EN60950/IEC950.
Cooling
The unit is designed to operate with 30 CFM of airflow.
Page 2
DNX301 4/2002 REV B
Output Voltages and Maximum Rated Loads
OUTPUT #1
V
OUT
I
MAX
±5V
±5V
±5V
±5V
±5V
±5V
±5V
±5V
45A
45A
45A
45A
45A
45A
45A
45A
MODEL NUMBER
DNX301-U3A
DNX301-U3B
DNX301-U4C
DNX301-U4D
DNX301-U4E
DNX301-U4F
DNX301-U4G
DNX301-U4H
OUTPUT #2
V
NOM
I
MAX
/I
PK
± 12V
± 15V
± 12V
± 12V
± 12V
± 15V
± 15V
± 15V
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
OUTPUT #3
V
NOM
I
MAX
/I
PK
± 12V
± 15V
± 12V
± 12V
± 12V
± 15V
± 15V
± 15V
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
8A/10A
OUTPUT #4
V
NOM
I
MAX
-
-
± 5V
± 24V
± 12V
± 5V
± 24V
± 12V
-
-
3.0A
1.5A
3.0A
3.0A
1.5A
3.0A
Note: Maximum current ratings are for 10sec maximum. Total power not to exceed 300 watts.
Output Specifications
Parameter
Regulation
Line
Load
Cross
Minimum Load
Output #1
Auxiliary Outputs
3.0A
0.1A
± 0.03%
±0.25%
±0.05%
Limits
Parameter
Voltage Adustment Range
PARD
Temperature
Operating
Storage
Temperature Coefficient (T
C
)
Conditions
20 MHz bandwidth
Min
Typ
±5
Max
1
Units
%
% P-P
0
-20
After half hour warm-up
± 0.02
50
+85
°C
°C
%/°C
DNX301 4/2002 REV B
Page 3
Mechanical
TOP VIEW
0.25
0.55
8.50
1.95
0.040
COVER
1
TB2
3.90
4.85
1
J9
1
OUTPUT NO. 1
5V RETURN
TB1
9.00
5V
6-32 THD 4 PLC’S
Maximum depth of mounting
scres is 0.156 inches
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.30”.
COOLING:
The DNX301 is designed to operate with 30 CM airflow.
SHOCK AND VIBRATION:
The DNX301 meets the requirements of MIL STD-810D.
WEIGHT:
Approximately 3 lbs.
Terminal Block 1
POS
1
2
3
FUNCTION
DC +
DC -
Ground
Terminal Block 2
POS
1
2
3
4
5
6
FUNCTION
-V2
+V2
-V3
+V3
-V4
+V4
J9 Connector
Molex No. 22-28-1090
PIN
1
2
3
4
5
6
7
8
9
FUNCTION
+ Sense
- Sense
N/C
N/C
Start Up Sync.
N/C
Remote Inhibit
Current Share
Control Signal Rtn
Page 4