Description
IGBT MODULE(600V/30A/PIM)
File Size649KB,7 Pages
ManufacturerFUJI
Websitehttp://www.fujielectric.co.jp/eng/fdt/scd/
Download Datasheet View All

7MBR30SA060 Overview

IGBT MODULE(600V/30A/PIM)

7MBR30SA060
IGBT MODULE (S series)
600V / 30A / PIM
IGBT Modules
Features
· Low V
CE
(sat)
· Compact package
· P.C. board mount
· Converter diode bridge, Dynamic brake circuit
Applications
· Inverter for motor drive
· AC and DC servo drive amplifier
· Uninterruptible power supply
Maximum ratings and characteristics
Absolute maximum ratings (Tc=25°C unless without specified)
Item
Collector-Emitter voltage
Inverter
Gate-Emitter voltage
Collector current
Collector power dissipation
Collector-Emitter voltage
Brake
Gate-Emitter voltage
Collector current
Collector power dissipation
Repetitive peak reverse voltage
Repetitive peak reverse voltage
Average output current
Surge current (Non-Repetitive)
I
2
t
(Non-Repetitive)
Symbol
V
CES
V
GES
I
C
I
CP
-I
C
P
C
V
CES
V
GES
I
C
I
CP
P
C
V
RRM
V
RRM
I
O
I
FSM
I
2
t
T
j
Continuous
1ms
1 device
Condition
Rat ing
600
±20
30
60
30
120
600
±20
20
40
80
600
800
30
210
221
+150
-40 to +125
AC 2500
AC 2500
3.5 *
1
Unit
V
V
A
A
A
W
V
V
A
A
W
V
V
A
A
A
2
s
°C
°C
V
V
N·m
Continuous
1ms
1 device
Converter
50Hz/60Hz sine wave
Tj=150°C, 10ms
half sine wave
Operating junction temperature
Storage temperature
T
stg
Isolation between terminal and copper base *2 V
iso
voltage between thermistor and others *3
Mounting screw torque
AC : 1 minute
*1 Recommendable value : 2.5 to 3.5 N·m (M5)
*2 All terminals should be connected together when isolation test will be done.
*3 Terminal 8 and 9 should be connected together. Terminal 1 to 7 and 10 to 24
should be connected together and shorted to copper base.
[Keysight Technology Thanksgiving Month Essay Contest] + Voice Recognition Control Keysight Oscilloscope
Oscilloscopes are the "eyes" of hardware engineers and are often used in circuit debugging and hardware fault location. Keysight oscilloscopes are basically multi-channel oscilloscopes that can test m...
qingfeng08 Test/Measurement
Wince RAS dial-up property settings
I created a cmnet in Wince for GPRS dial-up connection, but the default dial-up location in the connection properties is "Work", which will cause an extra "9" to appear before the dial-up number, turn...
lsbhjl Embedded System
The data read out by the sdram controller written by a privileged classmate are all FF?
I'm using an sdram controller written by a privileged classmate recently, but the data read out of the serial port is all FF. I don't know where the error is? Friends who have never used it to debug i...
baoluo8663 FPGA/CPLD
Problems with the use of lstAdd!
SESSION_POS_S *pTestpos1, *pTestpos2, *pTestpos3, *pPos; LIST *pMyList = NULL; int NodeIndex = 0; DPRINT("-------- lstAdd test-------"); pMyList == (LIST*)pro_malloc(sizeof(LIST)); lstInit((LIST*)pMyL...
glj1001 Embedded System
I forgot again, do the pull-up and pull-down resistors still work in the output state?
I forgot again, does the pull-up and pull-down resistors still work in the output state? If the IO port is set as output and the pull-up and pull-down resistors are enabled, does it work?...
wangfuchong Microcontroller MCU
Experts, please help me look at this program
#includereg51.h // Header file containing 51 MCU register definitions unsigned char code Tab[ ]={0xc0,0xf9,0xa4,0xb0,0x99,0x92,0x82,0xf8,0x80,0x90}; // Segment code of numbers 0~9 unsigned char int_ti...
飞利浦 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2805  1616  544  1724  147  57  33  11  35  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号