* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
5
Half-wave pulse of sine wave: 6 ms;detection time: 10
µ
s.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10
µ
s
.
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
f
1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
f
2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70
°
C
–40
°
to +158
°
F.
129
GQ
TYPICAL APPLICATIONS
• Telephone exchange, transmission
equipment
• Communications devices
• Measurement devices
• Home appliances, and audio/visual
equipment
• Handheld and portable products
ORDERING INFORMATION
Ex. AGQ
Contact arrangement Operating function
2: 2 Form C
0: Single side stable
1: 1 coil latching
2
0
0
A
1
H
Z
Coil voltage (DC)
1H: 1.5V
03 : 3V
4H: 4.5V
06 : 6V
09 : 9V
12 : 12V
24 : 24V
Packing style
Nil: Tube packing
Z: Tape and reel packing
(piked from 5/6/7/8
pin side)
Type of operation
0: Standard type
(B.B.M.)
Terminal shape
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. Suffix “X” instead of “Z”.
TYPES AND COIL DATA (at 20
°
C
68
°
F)
(1) Standard PC board terminal
Part No.
Operating
Function
Standard PC
board terminal
AGQ2001H
AGQ20003
AGQ2004H
AGQ20006
AGQ20009
AGQ20012
AGQ20024
Part No.
Operating
Function
Standard PC
board terminal
AGQ2101H
AGQ21003
AGQ2104H
AGQ21006
AGQ21009
AGQ21012
AGQ21024
Coil Rating,
V DC
1.5
3
4.5
6
9
12
24
Coil Rating,
V DC
1.5
3
4.5
6
9
12
24
Pick-up volt-
age, V DC
(max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Set voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Drop-out
voltage,
V DC (min.)
(initial)
0.15
0.3
0.45
0.6
0.9
1.2
2.4
Reset voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Nominal
operating
current,
mA (
±
10%)
93.8
46.7
31
23.3
15.5
11.7
9.6
Nominal
operating
current,
mA (
±
10%)
66.7
33.3
22.2
16.7
11.1
8.3
5.0
Coil resistance,
Ω
(
±
10%)
16
64.2
145
257
579
1,028
2,504
Coil resistance,
Ω
(
±
10%)
22.5
90
202.5
360
810
1,440
4,800
Nominal
operating
power, mW
140
140
140
140
140
140
230
Nominal
operating
power, mW
100
100
100
100
100
100
120
Max. allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
28.8
Max. allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
36
Single side
stable
1 coil
latching
1) Standard packing: 50 pcs. in an inner package (tube); 1,000 pcs. in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
(2) Surface-mount terminal
Part No.
Operating
Function
Tube packing
AGQ200
r
1H
AGQ200
r
03
AGQ200
r
4H
AGQ200
r
06
AGQ200
r
09
AGQ200
r
12
AGQ200
r
24
Tape and reel
packing
AGQ200
r
1HZ
AGQ200
r
03Z
AGQ200
r
4HZ
AGQ200
r
06Z
AGQ200
r
09Z
AGQ200
r
12Z
AGQ200
r
24Z
Coil Rating,
V DC
1.5
3
4.5
6
9
12
24
Pick-up
voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Drop-out
voltage,
V DC (min.)
(initial)
0.15
0.3
0.45
0.6
0.9
1.2
2.4
Nominal
operating
current,
mA (
±
10%)
93.8
46.7
31
23.3
15.5
11.7
9.6
Coil
resistance,
Ω
(
±
10%)
16
64.2
145
257
579
1,028
2,504
Nominal
operating
power,
mW
140
140
140
140
140
140
230
Max.
allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
28.8
Single side
stable
r
: For each surface-mounted terminal variation, input the following letter.
A type: A, S type: S
1) Standard packing: 50 pcs.(tube), 900pcs. (tape and reel)in an inner package; 1,000 pcs.(tube), 1,800pcs. (tape and reel)in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
130
GQ
Part No.
Operating
Function
Tube packing
AGQ210
r
1H
AGQ210
r
03
AGQ210
r
4H
AGQ210
r
06
AGQ210
r
09
AGQ210
r
12
AGQ210
r
24
Tape and reel
packing
AGQ210
r
1HZ
AGQ210
r
03Z
AGQ210
r
4HZ
AGQ210
r
06Z
AGQ210
r
09Z
AGQ210
r
12Z
AGQ210
r
24Z
Coil Rating,
V DC
1.5
3
4.5
6
9
12
24
Set voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Reset
voltage,
V DC (max.)
(initial)
1.13
2.25
3.38
4.5
6.75
9
18
Nominal
operating
current,
mA (
±
10%)
66.7
33.3
22.2
16.7
11.1
8.3
5.0
Coil
resistance,
Ω
(
±
10%)
22.5
90
202.5
360
810
1,440
4,800
Nominal
operating
power,
mW
100
100
100
100
100
100
120
Max.
allowable
voltage,
V DC
2.25
4.5
6.75
9
13.5
18
36
1 coil
latching
r
: For each surface-mounted terminal variation, input the following letter.
A type: A, S type: S
1) Standard packing: 50 pcs.(tube), 900pcs. (tape and reel)in an inner package; 1,000 pcs.(tube), 1,800pcs. (tape and reel)in an outer package
2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
DIMENSIONS
1. PC board terminal
10.60±0.3
.417±.012
5.20±0.2
.205±.008
7.20±0.3
.283±.012
3.20
.126
0.40±0.1
.016±.004
3.20±0.15
.126±.006
0.20±0.1
.008±.004
5.08±0.15
.200±.006
mm
inch
PC board pattern
Schematic (Bottom view)
Single side stable
(Deenergized condition)
1
2 3 4
2.20
.087
2.20
.087
5.08
.200
1 coil latching
(Reset condition)
1
2 3 4
2.20±0.15
.087±.006
3.50±0.3
2.20±0.15
.138±.012
.087±.006
8
7 6 5
8
7 6 5
8-0.85 dia.
8-.033 dia.
Direction indication
Direction indication
Tolerance:
±
0.1
±
.004
Suggested mounting pad
Single side stable/
1 coil latching
2. Surface-mount terminal
1) A type
Max. 5.40
.213
10.60±0.3
.417±.012
7.20±0.3
.283±.012
Schematic (Top view)
Single side stable
(Deenergized condition)
8
7 6 5
1 coil latcing
(Reset condition)
8
7 6 5
3.20
.126
0.40±0.1
.016±.004
3.20±0.15
.126±.006
2.20±0.15
.087±.006
2.20±0.15
.087±.006
0.20±0.1
.008±.004
5.08±0.15
.200±.006
8.40±0.3
.331±.012
2.20
.087
2.20
.087
2.66 6.74
.105 .265
0.80
.031
1
2 3 4
1
2 3 4
Direction indication
Direction indication
Suggested mounting pad
1) S type
Max. 5.40
.213
10.60±0.3
.417±.012
7.20±0.3
.283±.012
Single side stable/
1 coil latching
3.20
.126
2.20±0.15
.087±.006
2.20±0.15
.087±.006
0.20±0.1
.008±.004
5.08±0.15
.200±.006
7.20±0.3
.283±.012
0.80
.031
2.20
.087
2.20
.087
2.06
.081
6.14
.242
0.40±0.1
.016±.004
3.20±0.15
.126±.006
Tolerance:
±0.1
±.004
REFERENCE DATA
1. Max. switching capacity
DC resistive load
AC resistive load
2. Life curve
100
No. of operations,
×
10
4
Switching current, A
1.0
50
40
30
DC 30V resistive load
20
0.3
10
AC 125V
resistive load
30
100
Contact voltage, V
0
0.2
0.4
0.6
0.8
1.0
1.2
Switching current, A
131
GQ
NOTES
1. Coil operating power
1) As a general rule, only a pure DC pow-
er supply should be used for the coil drive.
2) To ensure proper operation, the voltage
applied to both terminals of the coil should
be
±5%
(at 20°C
68°F)
the rated operating
voltage of the coil. Also, be aware that the
pick-up and drop-out voltages will fluctu-
ate depending on the ambient tempera-
ture and operating conditions.
3) The ripple factor for the voltage applied
to the coil should be less than 5%.
4) For set and reset latching relays, the
rated operating voltage should be applied
to the coil for 10 ms or more.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or mal-
function.
3. External magnetic field
Since GQ relays are highly sensitive po-
larized relays, their characteristics will be
affected by a strong external magnetic
field. Avoid using the relay under that con-
dition.
4. Cleaning
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ul-
trasonic cleaning which subject the relay
to high frequency vibrations. It may cause
the contacts to stick.
lt is recommended that a fluorinated hy-
drocarbon or other alcoholic solvent be
used.
5. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1)stripe
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
mm
inch
Relay polarity bar
(Z type)
1.50
+0.1
dia.
0
.059
+.003
dia.
.0
2.0
.079
2.00dia.
4.00
.079dia.
.157
1.75
.069
Max. 6.55
.256
0.40
.016
11.5
.453
24.0±0.3
.945±.012
11.1
.437
GQ relays
12.0
.472
9.0
.354
Tape coming out direction
General tolerance
±0.1
mm
.004 inch
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
1.50
+0.1
dia.
0
.059
+.003
dia.
.0
2.0
.079
4.0 2.00dia.
.157 .079dia.
1.75
.069
11.5
.453
11.1
.437
Max. 6.55
.256
0.40
.016
24.0±0.3
.945±.012
GQ relays
12.0
.472
7.8
.307
Tape coming out direction
General tolerance
±0.1
mm
.004 inch
(2) Dimensions of plastic peel
mm
inch
21±0.8 dia.
.827±.031 dia.
2.0±0.5
.079±.020
100±1 dia.
3.937±.039 dia.
330±2 dia.
12.992±.079 dia.
24.4
+2
0
13±0.2 dia.
.961
+.079
0
.512±.008 dia.
2.0±0.2
.079±.008
Stopper (green)
Stopper (red)
6. Automatic insertion
To maintain the internal function of the re-
lay, the chucking pressure should not ex-
ceed the values below.
Chucking pressure in the direction A :
9.8 N {1 kgf} or less
Chucking pressure in the direction B :
9.8 N {1 kgf} or less
Chucking pressure in the direction C :
9.8 N {1 kgf} or less
A
C
B
Orientation (indicates PIN No.1)stripe
Stopper (green)
Stopper (red)
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be also
avoided.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).