EEWORLDEEWORLDEEWORLD

Part Number

Search

T92S7A32-277

Description
Power/Signal Relay, DPST, Momentary, 4000mW (Coil), 3A (Contact), 28VDC (Contact), AC Input, AC/DC Output, Panel Mount
CategoryMechanical and electronic products    relay   
File Size204KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

T92S7A32-277 Overview

Power/Signal Relay, DPST, Momentary, 4000mW (Coil), 3A (Contact), 28VDC (Contact), AC Input, AC/DC Output, Panel Mount

T92S7A32-277 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 221.6 V, COIL RELEASE VOLTAGE(AC): 27.7 V
body width34.54 mm
body height26.42 mm
Body length or diameter52.07 mm
Coil current (AC) maximum value0.05 A
Coil power4000 mW
Coil resistance5485 Ω
Maximum coil voltage (AC)277 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load3A@277VAC
Maximum contact current (AC)3 A
Maximum contact current (DC)3 A
Contact (DC) maximum rated R load3A@28VDC
Maximum contact voltage (AC)277 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Manufacturer's serial numberT92
Installation featuresPANEL MOUNT
operating hours25 ms
Maximum operating temperature65 °C
Minimum operating temperature-40 °C
physical size52.07mm X 34.54mm X 26.42mm
GuidelineCSA; UL; VDE
Relay actionMOMENTARY
Relay functionDPST
Relay typePOWER/SIGNAL RELAY
release time25 ms
sealSEALED TYPE
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
Catalog 1308242
Issued 3-03 (T92 pdf revised 2-04)
P&B
T92
series
Two-Pole, 30 Amp
PC Board or Panel Mount Relay
File E22575
File LR15734
File E22575 (type 2,3,4,5)
File No. 5386 (type 1,2,3,4)
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 30A DPST-NO and DPDT switching capabilities.
• Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA.
• Extended life – >300,000 operations at 30A, 240VAC (DC coil).
>100,000 operations at 30A, 240VAC (AC coil).
• Meets requirements of UL873 and UL508 spacings.
– .315” (8mm) through air, .375” (9.5mm) over surface.
• Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-contacts.
• Meets requirements of UL Class F construction.
• UL approved for 600VAC switching (1.5HP).
• Conforms to VDE 0435, 0631, and 0700.
• New screw terminal version.
Coil Data (@ 25
°
C Coil Temperature)
Nom. Voltage
(VDC)
12
24
DC Coils (1.7W)
DC Resist.
Nom. Voltage
(VDC)
±
10% (Ohms)
86
48
350
110
±
10% (Ohms)
1,390
7,255
Freq.
50/60
50/60
50/60
DC Resist.
950
3800
5485
DC Resist.
AC Coils (4.0VA)
Nom. Voltage Freq.
DC Resist.
Nom. Voltage
(VAC)
(VAC)
±
10% (Ohms)
12
60
9.1
110/120
24
60
36.6
220/240
250/277
±
10% (Ohms)
Contact Ratings @ 25°C with relay properly vented.
Remove tape over vent hole after soldering and cleaning.
Arrangements:
2 Form A (DPST-NO) and 2 Form C (DPDT).
Materials:
Silver cadmium oxide.
Max. Load Rating:
Normally Open Contacts:
30A @ 120/277VAC, resistive;
10A @ 600VAC, resistive;
1 HP @ 120VAC, 3 HP @ 240VAC;1.5 HP @ 480VAC, 1.5 HP @ 600VAC
110 LRA, 25.3 FLA, @ 240VAC with DC coil
(1)
;
60 LRA, 14 FLA @ 240VAC with AC coil
.
3A @ 240VAC pilot duty;
20A @ 28VDC;
TV10 @ 120VAC.
VDE Rating (Flange Mount):
25A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
VDE Rating (PC Mount):
30A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
Normally Closed Contacts:
3A @ 28VDC or 277VAC, 2A @ 480VAC, 1A @ 600VAC.
VDE Rating (Flange or PC Mount):
3A @ 400VAC, 30K Ops.
Min. Load Rating:
Normally Open Contacts:
500mA @ 12VAC/VDC.
Normally Closed Contacts:
100mA @ 6VAC/VDC.
Expected Mechanical Life:
5 million operations.
Expected Electrical Life:
100,000 operations at rated load.
ARI 780-86 Endurance Test (section 6.6):
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
Single Phase/Two Pole (Both poles together switching a single load)
110 LRA, 25.3 FLA, 200K operations (DC Coil).
L1
L2
T1
T2
L1
T1
L2
T2
Ambient Temperature vs. Coil Voltage
120
Max. Allowable
Ambient Temp. (°C)
100
80
60
40
20
0
70
75 80
85
AC
Coi
l0A
AC
Coi
l 30
A
DC C
oil 0
Amp
Cont
DC C
act L
oil 30
oad
Amp
Cont
act L
oad
90
95 100 105 110 115 120 125 130 135 140 145 150
Applied Coil Voltage (% of Rated Nominal)
Assumptions:
1. Thermal resistance = 35°C per Watt (DC only.)
2. Still air.
3. Nominal coil resistance.
4. Max. mean coil temperature = 155°C (change of resistance method).
5. Coil temperature rise due to load = 6.3°C @ 30 amps.
6. Curves are based on 1.7W at 25°C (DC only.)
Operate Data
Must Operate Voltage: AC Coil:
80% of nominal voltage or less.
DC Coil:
75% of nominal voltage or less.
Must Release Voltage:
10% of nominal voltage or more.
Initial Operate Time
(2)
:
15 ms typical, (25 ms max. w/bounce).
Initial Release Time
(2)
:
10 ms typical, (25 ms max. w/bounce).
Max Operating Frequency:
14 operations per minute.
Environmental Data
Temperature Range: Storage:
-55°C to +155°C.
Operating: AC Coil:
-40°C to +65°C.
DC Coil:
-40°C to +85°C.
Vibration:
0.065” (1.65mm) double amplitude for 10-55 Hz., functional.
Shock, Operational:
10g for 11 ms, 1/2 sine wave pulse with no contact
opening > 100µs.
Shock, Mechanical:
100g for 11 ms, 1/2 sine wave pulse.
Flammability:
UL 94V-0.
Single Phase Per Pole (Single load per pole)
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
Notes:
Vent hole tape must be removed to achieve all listed ratings.
Consult factory regarding ratings for screw terminal versions.
Mechanical Data
Termination:
Printed circuit terminals; .250” (6.35mm) quick connects for
coil and contacts; .187” (4.75mm) quick connects for coil
and .250” (6.35mm) quick connects for contacts; or M4
screws with captive pressure plates for coil and contacts.
Enclosure:
Unsealed, plastic dust cover or immersion cleanable, tape
sealed plastic cover.
Weight:
3 oz. (86g) approximately.
Initial Dielectric Strength
Between Contacts and Coil:
4,000V rms, 50/60 Hz.
Between Open Contacts:
1,500V rms, 50/60 Hz.
Between Poles:
2,000V rms, 50/60 Hz.
Initial Insulation Resistance
Between Mutually Insulated Elements:
10
9
ohms, min. @ 500VDC.
Coil Data
Voltage:
12 through 110VDC and 12 through 277VAC.
Resistance:
See Coil Data table.
Nom. Power: AC Coil:
4.0VA;
DC Coil:
1.7W.
Coil Temp. Rise:
35°C/W.
Max. Coil Temp.:
155°C.
Duty Cycle:
Continuous.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Conditions
All parametric, environmental and life tests are performed according to EIA
Standard RS-407-A at standard test conditions (25°C ambient, 20-50% RH,
29.5
±
1” Hg.) unless otherwise noted.
Notes
(1) FLA, LRA ratings are compatible with 3.5 ton compressor applications.
(2) Nominal voltage, no coil suppression, excluding bounce.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
511
Refer to inside back cover.
PHILIPS STARplug TEA152X series of high-efficiency, low-power power management devices
OverviewThe TEA152x series is a controller IC for switching power supplies that directly rectifies the general main circuit. It is manufactured using the high voltage EZ-HV SOI process and the low vol...
zbz0529 Power technology
433MHz wireless communication based on STM32F769I vehicle warning device
[i=s]This post was last edited by beyondvv on 2017-1-2 23:09[/i] [color=#333333]433MHZ is the application-free transmission and reception frequency in our country. It can be used directly without appl...
beyondvv stm32/stm8
If the scsi/raid driver is not installed on the server, will it affect the performance?
I have a server now. I installed Linux before, but didn't care about the driver. Now I changed to Windows, and it prompts that the scsi/raid controller driver is not installed. I checked online and it...
nx0105 Embedded System
Embedded
Looking for DC motor application source code and vcw file...
jp19848 Embedded System
Urgent usage of stm32f4 usb OTG
Hello everyone, I have a question to ask the seniors in the forum, I hope to get some advice from the experts, I will be very grateful. I am currently using the stm32f4 discovery board, and I want to ...
haohongyu stm32/stm8
Opencore's can kernel has problems in sopc compilation
There is no problem in generating the IP core, but when compiling and generating the schematic diagram, it prompts that there is a problem. Error: cpu/instruction_master: Base Address for can_control/...
tianma123 FPGA/CPLD

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 942  1072  1801  140  99  19  22  37  3  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号