RFB300/350 Series
24Vin and 48Vin single output
308W and 350W Half brick
NEW Product
DC/DC CONVERTERS
•
•
•
•
•
•
•
1
High efficiency topology
Wide temperature range, -40°C to +100°C @ full power
High power density (160W/in
3
in 0.4” tall version)
Input voltage range: 18V to 36V or 36V to 75V
Output voltage range: 7.2V to 13.2V or 16.8V to 29.4V
Remote ON/OFF
Operational insulation system
RFB300/350 series is a high efficiency, enclosed, isolated DC/DC converter series in
an industry standard half brick package that provides up to 350W of output power.
The series delivers very high usable output power for today’s high performance RF
power amplifier and similar applications. The four models in the series feature an
input voltage range of 18 to 36VDC and 36 to 75VDC and an output voltage of 12V
and 28V. The output voltage is adjustable from 7.2V to 13.2V or 16.8V to 29.4V (not
to exceed 308W for the RFB300 and 350W for the RFB350). The series also has a
remote ON/OFF capability. Over current, over voltage and over temperature
protection features are included as standard. Negative logic remote ON/OFF and
other options are also available. Full international safety approval including
EN/IEC60950 VDE and UL/cUL60950 reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
External output capacitance required (See Note 4)
ABSOLUTE MAXIMUM RATINGS
Input voltage - peak
(100ms max.,
1% duty cycle max.)
24Vin
48Vin
-0.5V to 50V
-0.5V to 100V
-0.5V to 40V
-0.5V to 80V
-0.5V to 12V
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
EN55022
EN55022
2 YEAR WARRANTY
SPECIFICATIONS
See Application Note 167
See Application Note 167
Input voltage continuous 24Vin
48Vin
Adjust pin voltage (with
respect to -sense pin)
OUTPUT SPECIFICATIONS
Voltage adjustability
Min./max. load
12V
28V
12V
28V
GENERAL SPECIFICATIONS
Efficiency
24Vin
Vin=Vin(nom), Iout (max.) 48Vin 12V model
48Vin 28V model
Approvals and
standards
90%
88%
91%
VDE IEC60950,
IECEE CB, UL/cUL60950
UL94V-0
0.5” tall version
Telcordia SR-332,
Issue 1
110g (3.88 oz.)
2,000,000 hours
7.2V to 13.2V
16.8V to 29.4V
0/29.2A
0/11A, 0/12.5A
470µF to 4,700µF
330µF to 3,300µF
5ms typ.
Material Flammability
Weight
MTBF @ 55ºC
Output load capacitance 12V
(See Note 10)
28V
Rise time
(See Note 12)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating baseplate,
temperature
Non-operating
-40ºC to +100ºC
-40ºC to +100ºC
INPUT SPECIFICATIONS
Input current
(See Note 3)
Input reflected ripple
(See Note 4)
Input capacitance -
Internal filter
Inrush current
(See Note 11)
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-0198
Licence No. 40005395
UL/cUL CAN/CSA 22.2 No. 60950
UL 60950 File No. E135734
24Vin
48Vin RFB300
48Vin RFB350
24Vin
48Vin 12V model
48Vin 28V model
24Vin
48Vin
23.3A max. @ lo max.
11.2A max. @ lo max.
13.0A max. @ lo max.
12mA (pk-pk)
42mA (pk-pk)
28mA (pk-pk)
30µF
6.6µF
2A
2
sec.
RC PIN ELECTRICAL INTERFACE
Open collector compatible
RC:
ON voltage
(See
Open circuit voltage
High level leakage current (See
OFF voltage
(See
Low level input current
(See
(See AN 167 for remote ON/OFF)
5.0V min.
5V min, 11V typ, 13V max.
Note 14)
-25.0µA max.
Note 15)
1.2V max.
Note 16)
-250µA max.
Note 13)
File Name: rfb300_350.pdf Rev (01): 16 Sept 2004
RFB300/350 Series
24Vin and 48Vin single output
308W and 350W Half brick
NEW Product
DC/DC CONVERTERS
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
308W
308W
350W
350W
INPUT
VOLTAGE
18 - 36VDC
36 - 75VDC
36 - 75VDC
36 - 75VDC
OUTPUT
VOLTAGE
16.8V - 29.4V
16.8V - 29.4V
7.2V - 13.2V
16.8V - 29.4V
OUTPUT
CURRENT
(MIN.)
0A
0A
0A
0A
OUTPUT
CURRENT
(MAX.)
11.0A
11.0A
29.2A
12.5A
EFFICIENCY
(TYP.)
90%
91%
88%
91%
REGULATION
LINE
±0.15%
±0.15%
±0.15%
±0.15%
LOAD
±0.2%
±0.2%
±0.2%
±0.2%
MODEL
NUMBER
(7)
RFB300-24S28
RFB300-48S28
RFB350-48S12
(17)
RFB350-48S28
Part Number System with Options
RFB300-24S28-R5T
Threaded Inserts
T = Threaded Inserts
Blank = Clearance Inserts
Product Family
RFB = Half-Brick
Rated Output Current
300 = 308W
350 = 350W
Input Voltage
24 = 18 to 36V
48 = 36 to 75V
Number of Outputs
S = Single
Height Option
(17)
5 = 0.50in (12.70mm)
4 = 0.40in (10.16mm)
Remote ON/OFF Polarity
R = Negative Logic Option
Blank = Positive Logic Option
Output Voltage
12 = 7.2 to 13.2V
28 = 16.8 to 29.4V
Notes
1
Measurement Bandwidth: 20MHz; Measured with 1µF ceramic and a
330µF (470µF for 12V output model) aluminum or solid tantalum
capacitor across the output terminals.
Di/dt = 1A/µs; ∆I
out
= ±25% Iout (max); Vin = Vnom; Iout = Inom. Tested
with a 1µF ceramic and a 330µF (470µF for 12V output model) aluminum
electrolytic capacitor across the output.
External input fusing required. Use a fast acting fuse: 40A (24V model),
15A (48V, 350W model).
Iout = Iout (max) Measured with the input capacitor, Cbypass = 330µF,
and 6µH inductor in series with the power source. Frequencies >100kHz.
Signal line assumed <3m in length.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand-alone product.
Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example see part numbering system.
With the enable signal asserted, this is the time from when the input
current reaches 10% of the final steady state value until the output
voltage reaches 10% of the nominal output value. Start-up into resistive
load.
With Vin > Vin (min) applied for a minimum of 1 second, this is the time
from when the primary ON/OFF signal is activated until the output
voltage reaches 10% of the nominal output voltage.
Notes Contd.
10
Minimum effective ESR is 1mΩ. Minimum phase margin is 35º.
11
Measured per ETSI 300 132-2 Section 4.7.2.
12
From 10% to 90% of Vout(nom). Full resistive load. 1µF ceramic and
330µF (470µF for 12V model) electrolytic capacitors across the output.
13
Converter guaranteed ON for positive option.
14
Maximum driver leakage to insure converter is ON.
15
Converter guaranteed OFF for positive option.
16
Driver sink current @ Vrc ≤ 1.2V.
17
0.40in height option is not available on the 12V output model.
2
3
4
5
6
7
8
PROTECTION
Short-circuit
(Brickwall current
limiting)
Over-voltage protection
(Output shutdown)
Over-temperature
shutdown
12V model
28V model RFB300
28V model RFB350
12V model
28V model
(midpoint of baseplate)
39.4A
14.3A
16.3A
15.0V
33.2V
110ºC
9
File Name: rfb300_350.pdf Rev (01): 16 Sept 2004
RFB300/350 Series
24Vin and 48Vin single output
308W and 350W Half brick
NEW Product
DC/DC CONVERTERS
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
-IN
Case
330µF
RC
+IN
-Out
-Sen
Vadj
+Sen
+Out
1µF
50V
330µF
330µF
-IN
Case
-Out
-Sen
Vadj
1µF
50V
470µF
RC
+IN
+Sen
+Out
Figure 1 - Standard Application - 28V Output Models
Figure 2 - Standard Application - 12V Output Model
12
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
-20
0
20
40
60
80
100
10
8
6
4
2
0
-40
14
12
10
8
6
4
2
0
-40
-20
0
20
40
60
80
100
TEMPERATURE (ºC) BASEPLATE
Figure 3 - De-rating Curve - RFB300 - 28V Models
TEMPERATURE (ºC) BASEPLATE
Figure 4 - De-rating Curve - RFB350 - 28V Model
30
OUTPUT CURRENT (A)
25
20
15
10
5
0
-40
-20
0
20
40
60
80
100
TEMPERATURE (ºC) BASEPLATE
Figure 5 - De-rating Curve - RFB350 - 12V Model
Figure 6 - Typical Turn-on Delay and Risetime RFB350-48S28
Channel 1: Input Voltage, Channel 2: Output Voltage
File Name: rfb300_350.pdf Rev (01): 16 Sept 2004
RFB300/350 Series
24Vin and 48Vin single output
308W and 350W Half brick
NEW Product
DC/DC CONVERTERS
4
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
91
EFFICIENCY (%)
89
87
85
83
0
3
6
9
12
Vin = 24V
92
EFFICIENCY (%)
90
88
86
84
0
3
6
9
12
Vin = 48V
OUTPUT CURRENT (A)
Figure 7 - Typical Efficiency vs. Output Current – RFB300-24S28
OUTPUT CURRENT (A)
Figure 8 - Typical Efficiency vs. Output Current – RFB300-48S28
92
EFFICIENCY (%)
EFFICIENCY (%)
91
90
89
88
87
86
85
0
2
4
6
8
10
12
14
Vin = 48V
92
90
88
86
84
0
6
12
18
24
30
Vin = 48V
OUTPUT CURRENT (A)
Figure 9 - Typical Efficiency vs. Output Current – RFB350-48S28
OUTPUT CURRENT (A)
Figure 10 - Typical Efficiency vs. Output Current – RFB350-48S12
Figure 11 - RFB350-48S28 Transient Response
Load 6.25A to 9.38A
Figure 12 - RFB350-48S12 Transient Response
Load 14.5A to 21.75A
File Name: rfb300_350.pdf Rev (01): 16 Sept 2004
RFB300/350 Series
24Vin and 48Vin single output
300W and 350W Half brick
NEW Product
DC/DC CONVERTERS
5
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
7x ø0.040 (1.02)
2x ø0.081 (2.06)
2.000 (50.80)
-Vin
-Vout
Case
-Sen
Vadj
2.39
±0.01
(60.71
±0.25)
Case Footprint
RC
+Sen
+Vin
+Vout
0 (0.00)
0.197 (5.01)
1.900 (48.26)
0
0.187 (4.75)
0.23
±0.15
(5.84
±3.81)
Do not place labels
on base footprint
HEIGHT
See Dimension Option Table
0.00 (0.00)
2.27
±0.01
(57.66
±0.25)
Case Footprint
PIN CONNECTIONS
PIN NUMBER
-Vin
DIMENSION OPTIONS
OPTION
5
4
HEIGHT
0.50 +0.05, - 0.15 (12.70 +1.27, -3.81)
0.40 +0.05, -0.15 (10.16 +1.27, -3.81)
Case
RC
+Vin
+Vout
+Sen
Vadj
-Sen
-Vout
ON/OFF Control Terminal
Positive Input Terminal
Positive Output Terminal
Positive Remote Sense
Output Adjustment Trim Pin
Negative Remote Sense
Negative Output Terminal
FUNCTION
Negative Input Terminal
Figure 13 - Mechanical Drawing, Dimension Options and Pin-Out Table
Data Sheet © Artesyn Technologies® 2004
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:
✔
Application Note
www.artesyn.com
File Name: rfb300_350.pdf Rev (01): 16 Sept 2004