D4N-3280

Description
Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, Screw Terminal, Cat Whisker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size6MB,24 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4N-3280 Overview

Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, Screw Terminal, Cat Whisker Actuator, Panel Mount

D4N-3280 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator typeCAT WHISKER
Other featuresP.T.= 15 DEG, T.T.= 15 DEG
body width30 mm
body height57.5 mm
Body length or diameter31 mm
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)2.5 A
Contact (DC) maximum rated R load2.5A@250VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)250 V
Electrical life300000 Cycle(s)
Installation featuresPANEL MOUNT
Maximum operating force1.5 N
Maximum operating temperature70 °C
Minimum operating temperature-30 °C
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSCREW
Base Number Matches1
Safety Limit Switch
D4N
CSM_D4N_DS_E_4_1
Upgraded Safety Limit Switches Based
on the Popular D4D, Providing a Full
Lineup Conforming to International
Standards
• Lineup includes three contact models with 2NC/1NO and 3NC
contact forms in addition to the previous contact forms 1NC/
1NO, and 2NC. Models with MBB contacts are also available.
• M12-connector models are available, saving on labor and
simplifying replacement.
• Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
• Conforms to EN115, EN81-1, and EN81-2 (slow-action models
only).
• Lineup includes both slow-action and snap-action models with
Zb contacts.
• Certified standards: UL, EN (TÜV), and CCC
Be sure to read the
“Safety Precautions”
on page 18
and the
“Precautions for All Safety Limit Switches”
.
Note:
Contact your sales representative for details on models
with safety standard certification.
Model Number Structure
Model Number Legend
D4N-@@@@
1 2
3
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top Plunger
32: Top Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE: Fork lever lock (right operation)
LE: Fork lever lock (left operation)
1. Conduit size
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
1
AD conversion problem
I'm begging for help on how to use PCF8591. Thanks....
51新手 51mcu
DIY [CNC power supply] Physical object 1 debugging in progress
Structure Introduction The DCDC on the top provides positive and negative power for the op amp, the LM3S811 board on the left in the middle, the power regulation part of the CNC power supply on the ri...
蓝雨夜 Microcontroller MCU
About OMAPL138 switching between network port tasks and other tasks in BIOS
I am working on the network communication of OMAP L138, using DSP/BIOS NDK, and making the network port a separate task, without creating other tasks statically. In this way, the network communication...
三九天使 DSP and ARM Processors
How is the confidentiality of msp 430!
People say TI has good confidentiality,how about 430?...
南海渔歌 Microcontroller MCU
Why do I use DS1302 to display the time on the digital tube, but it is always 0?
Why do I use DS1302 to display the time on the digital tube, but it is always 0?...
ylf175300 51mcu
Some issues with DSP
Hello everyone, I am new to DSP and would like to know the debugging steps of DSP. If anyone can leave a message to explain it to me, I will be grateful. Also, I need some current DSP debugging progra...
jjphero Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1077  1248  1174  2720  1387  22  26  24  55  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号