See Performance Data: refer to page Important-2 of the A113
Industrial Controls
catalogue.
➋
Operating temperature below 0°C (32°F) are based on the absence of freezing
moisture and liquids.
➌
Per IEC 947-1.
➍
UL File & Guide Number E14840.
Silver nickel alloy
Fine silver
Palladium silver
Gold-plated over
alloy: spanner; gold- silver
plated silver nickel:
stationary contacts
Terminals:
Screw type Plated steel
Push-on type
Agency approvals
Approvals
UL listed
➍/CSA
certified
Standard conformity
UL508, UL486E
NEMA ICS-1 and
CSA22.2 #14,
ICS-2 IEC 204-1,
NEMA ICS-1 and
947; SEV 1005,
ICS-2 (1983), IEC
1093; VDE 0113,
144, IEC 947-1, IEC 0660 Part 201; BS
947-5, VDE 0550,
4794; CEE 24; UL
VDE 0660, Part 200 486E, UL 508,
CSA22.2 #14
6-14
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—22.5mm
2-Position Push-Pull Operators, Non Illuminated—Twist-to-Release, Push-Pull
40mm Trigger Action
Twist-to-Release Mushroom
40mm Twist-to-Release Mushroom
40mm Push-Pull Mushroom
800E-15YE112
Legend Plate for 40mm Ca
Colour
Operator Material
Plastic
Metal
40mm Mushroom Operator
Twist-to-Release — Round (Trigger Action)
!
Push-Pull Twist-to-Release — Round
➋
Push-Pull — Round
➋
Catalogue Number
800EP-MTS44
800EM-MTS44
800EP-MT4
800EM-MT4
800ES-MP24
800EM-MP24
Red
Plastic
Metal
Plastic
Metal
2-Position Trigger Action Operators, Non Illuminated—Key Release
➌
40mm Key Release Mushroom
60mm Key Release Mushroom
800E-16YE112
Legend Plate for 60mm Cap
Colour
2 Position Trigger Action
!
Mushroom Operator
Ronis Key Lock
Size
40mm—Round
60mm—Round
40mm—Round
60mm—Round
Catalogue Number
800EP-MKR44
800EP-MKR64
800EP-MKZ44
800EP-MKZ64
Red
Zadi Key Lock
Back-of-Panel Components, Non Illuminated Operators
Mounting Latch and
Contact Block Combination
Mounting
2-Across
Contact
➊➋
1 N.C. Late break
1 N.O. - 1 N.C. Late break
1 N.C. Late break
1 N.O. - 1 N.C. Late break
1 N.C. Self-monitoring
3-Across
800E-3LX01S
!
Trigger action operators are compliant with EN418 standards using standard N.C., N.C. Late Break, or N.C. Self-Monitoring contact blocks. Key Release operators are
IP66, Type 4/13.
➋
Emergency stop push buttons are compliant with EN 418 standard when using N.C. Late break (N.C.L.B.) contact blocks.
➌
Key release operators are IP66, Type 4 and 13.
2-Across
3-Across
Catalogue Number
800E-2LX01L
800E-2LX11L
800E-3LX01L
800E-3LX11L
800E-2LX01LS
3-Across
2-Across
6-15
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—22.5mm
2-Position Red Push-Pull Operators, Illuminated —Mushroom
➊
40mm Mushroom Push-Pull
60mm Jumbo Mushroom Push-Pull
800E-15YE112
Legend Plate for 40mm Cap
Operator Material
Plastic
Size
40mm
60mm
40mm
Catalogue Number
800ES-LMP24
800ES-LMJP24
800EM-LMP24
800EM-LMJP24
Metal
60mm
Back-of-Panel Components,
Illuminated Operators
2-Across
(5 ckts. max.)
3-Across
(4 ckts. max.)
Mounting
Type
Incandescent
Volts
24 AC/DC
120 AC/DC
Catalogue Number
800E-2DL3
800E-2DL5
800E-2DL3R
800E-2DL5R
800E-3DL3
800E-3DL5
800E-3DL3R
800E-3DL5R
800E-2TL5
800E-2TL7
800E-2TL5R
800E-2TL7R
800E-3TL5
800E-3TL7
800E-3TL5R
800E-3TL7R
2-Across
24 AC/DC
LED (red)
120 AC
24 AC/DC
Incandescent
Full Voltage Power Module with Latch
3-Across
LED (red)
Incandescent
2-Across
LED (red)
Incandescent
3-Across
Transformer Power Module with Latch
2-Across
3-Across
120 AC/DC
24 AC/DC
120 AC
24 AC/DC
120 AC/DC
24 AC/DC
120 AC
24 AC/DC
120 AC/DC
24 AC/DC
LED (red)
120 AC
2-Across (3 ckts. max.)
3-Across
(2 ckts. max.)
2-Across
Late Break
!
800E-2X01L
1 N.C. Late break
800E-3X01L
3-Across
Contact Blocks
!
Emergency stop push buttons are compliant with EN 418 standard when using N.C.L.B. contact blocks.
6-16
Emergency Stop Devices
Push Buttons
800 E-Stops
!
Specifications—30.5mm
Electrical Ratings
Dielectric strength
Electrical design life cycles
Mechanical Ratings
Vibration
2200V for one minute
1,000,000 at max. rated load
10 to 2000Hz 1.52mm displacement
(peak-to-peak) max./10g max. (except
Logic Reed)
1/2 cycle sine wave for 11ms
≥25g
(contact fragility) and no damage at 100g
Type 1, 4, 4X, 12, 13; watertight/oiltight
IEC 529 IP66/65
Shock
Degree of protection
Mechanical design life
cycles
250,000 min.
(Push-pull/twist-to-release)
Contact operation
Shallow, mini, and low voltage contact
blocks: Slow, double make and break.
Typical operating forces
7.5lbs max. push or pull
2-position push-pull
Environment
Temperature range
Operating
➋
-40°C to +55°C (-40°F to +131°F)
Storage
-40°C to +85°C (-40°F to +185°F)
Standard Contact Ratings
Maximum thermal continuous current
I
th
10A AC/2.5A DC.
Bulletin 800T units with 800T-XA contacts have ratings as follows:
Max.
Opertnl.
Volts Ue
Utilization
Category
IEC
NEMA
A600
Rated Operational Currents
Volts Ue
120 to 600
72 to 120
24 to 72
28 to 600
24 to 28
➌
Make
Break
7200VA
720VA
60A
720VA
60A
10A
69VA
2.5A
AC 600
AC-15
DC 600
DC-13
Q600
!
Performance Data: see publication A113, page Important-2.
➋
Operating temperatures below freezing are based on the absence of moisture
and liquids.
➌
For applications below 24V/24mA, PenTUFF contacts are recommended.
6-17
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—30.5mm
Emergency Stop Operators — 2-Position Red Non Illuminated
2-Position Push-Pull
2-Position Push-Pull/Twist
Operator Position
Contacts Maintained Out Maintained In
Enclosure
Protection
Type 4 & 13
Release
Push-Pull
Catalogue Number
800T
-FX6D4
800T
-FXT6D4
N.C.L.B.
!
Closed Open
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
N.O. Open Closed
N.C.L.B.
!
Closed Open
Type 4 & 13
800T
-FXT6A1
Push-Pull/Twist
Type 4, 4X & 13
N.C.L.B.
!
Closed Open
N.C.L.B.
!
Closed Open
Push-Pull
Type 4 & 13
800T
-FXT6A5
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
S.M.C.B.
➊➋
Closed Open
Type 4 & 13
800TC-FXT6D4S
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
N.O. Open Closed
S.M.C.B.
➊➋
Closed Open
Type 4 & 13
800TC-FXT6A1S
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
S.M.C.B. Closed Open
S.M.C.B.
➊➋
Closed Open
Type 4 & 13
800TC-FXT6A5S
Push-Pull/Twist
Type 4, 4X & 13
Note:
Emergency stop push buttons are compliant with EN-418 and IEC 60947-5-5 Standards when using N.C.L.B. contact blocks.
➊
Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts
change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs.
➋
The Self-Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically
closes when the S.M.C.B. is properly installed onto the E-Stop operator. If the S.M.C.B. is separated from the E-Stop operator, the N.O. monitoring contact will
I have been engaged in PCB design for a while, and I have always been troubled by a problem. When I do PCB design, I always see various different grounds, but I don’t understand why so many different ...
Please ask the experts: Environment: MPC8270, tornado 2.2 The address AD22 of the miniPCI device connected to the IDSEL# of the CPU MMU and PCI automatic configuration #define INCLUDE_MMU_BASIC /* #de...
The ACS712 acquisition part is shown in the figure above. When an AC 12V voltage is passed through the primary side of the ACS712 and a resistive load is directly connected to the AC 12V voltage, the ...
[font=微软雅黑][size=3]Hello, all EEWORLD forum members! [/size][/font] [font=微软雅黑][size=3] [/size][/font] [font=微软雅黑][size=3] After several months of unremitting efforts and the strong support of all ent...
When I was debugging the touch screen XPT2046 (IC), I set the touch interrupt. I could enter the interrupt when touching, but I couldn't jump out of the interrupt. I used an oscilloscope to observe an...
1 Introduction Population aging has become a prominent social issue in today's world. According to the United Nations, in 2002, the total number of elderly people (aged 60 and over) in the world reach...
On August 23rd, Geely's subsidiary, Jiyao Tongxing, announced it has the industry's largest advanced production capacity for tandao
batteries
, with eight production bases across China. Jiy...[Details]
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
Reflow soldering, a common soldering method in modern electronics manufacturing, primarily melts solder paste and pads to form solder joints. With technological advancements, soldering equipment ha...[Details]
When you are happily watching NBA or football, your wife asks you to turn off the lights in the bedroom. Would you be depressed? Of course, unless you are not afraid of your wife.
Now you are ...[Details]
introduction
As “energy conservation and emission reduction” has become an indicator of the National Economic Development Outline of the 11th Five-Year Plan, people’s awareness of green enviro...[Details]
introduction
According to the China Fire Statistics Yearbook, electrical fires accounted for more than 30% of fire accidents in the past decade, and the trend is increasing year by year. They ...[Details]
Overview
As handheld voice communication devices become more and more popular, they are increasingly used in noisy environments, such as airports, busy roads, crowded bars, etc. In such noisy ...[Details]
In the scorching summer, electric fans are a must-have for cooling down people's homes. However, I believe most people have encountered this situation: the fan is plugged in, the switch is pressed,...[Details]
Intel®
Xeon®
6
-
core processors now support the new Amazon EC2 R8i and R8i-flex instances on Amazon Web Services (AWS).
These new instances offer superior performance and fast...[Details]
Smartphones can be incredibly unintelligent. For example, consider an office full of people, each absorbed in their work. Suddenly, the silence is broken by a burst of loud pop music. A colleague's...[Details]
The fracture mechanism is stress concentration, which typically occurs at the capacitor lead pins or pad connection points, as shown in the figure. Under vibration, the capacitor lead pins and pad ...[Details]
Batteries are a core component of new energy vehicles, accounting for over 40% of the total cost. This is also the area where automakers are most willing to tamper with costs. Since 2021, domestic ...[Details]
For the average person, an electricity meter is a monthly bill. For beginners, it's a collection of components and parts. For experienced meter engineers, however, it's a complex and complex proces...[Details]
According to foreign media reports, Apple is secretly evaluating several artificial intelligence hardware concepts, including smart home displays, security devices and a desktop robot, of which the...[Details]
01 Overview
The HJM315A/B is a domestically produced programmable three-phase motor driver specifically designed for small and medium-sized motor gyroscopes. It consists of an MCU, LDO, three-...[Details]