EC30B4-8

Description
Rotary Coded Switch, 8 Positions, Binary Coded, Latched, 3A, 28VDC, Screw Terminal, Panel Mount-threaded,
CategoryMechanical and electronic products    switch   
File Size84KB,3 Pages
ManufacturerJanco Rotary Products
Download Datasheet Parametric View All

EC30B4-8 Overview

Rotary Coded Switch, 8 Positions, Binary Coded, Latched, 3A, 28VDC, Screw Terminal, Panel Mount-threaded,

EC30B4-8 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
body height46.73 mm
Body length or diameter26.2 mm
Maximum contact current (DC)3 A
Contact (DC) maximum rated R load3A@28VDC
Maximum contact voltage (DC)28 V
Graduation angle30 deg
Installation featuresPANEL MOUNT-THREADED
Number of positions8
Number of switching segments4
surface mountNO
Switch actionLATCHED
switch functionBINARY CODED
Switch typeROTARY CODED SWITCH
Termination typeSCREW
Base Number Matches1
Indexing
Miniature
Rotary
Selector
Switch
Printed
Circuit
NOTES:
Series
EC
Designed in
accordance with
the requirements
of MIL-S-3786
and 22710.
15°
18°
22°
30°
36°
45°
15°:
2 NUMBER OF POSITIONS: 15 :
18°:
18 :
22°:
22 :
30°:
30 :
36°:
36 :
45°:
45 :
15°
24 Positions
18°
20 Positions
22°
16 Positions
30°
12 Positions
36°
10 Positions
45°
8 Positions
4 For deck identification. decks will be identified
A, B, C, etc. adjacent to common terminal.
3 All terminals will be supplied
regardless of number of positions required.
2-24
2-20
2-16
2-12
2-10
2-8
ELECTRICAL RATING: Continuous 3 amps @ 28 vdc.
MAKE AND BREAK:
.100 amp res. 115 vac
(25,000 CYCLES)
.100 amp res. 28 vdc.
DIELECTRIC STRENGTH: 750 vrms
TORQUE TO ROTATE: 36 in. oz. max.
LENGTH: 1.00 [25,4] for 1 deck switch, add
.280±.015 [7,11 0,38]
.280 .015 [7,11±0,38] for each additional deck
WEIGHT: .12 lb. max. for 1 deck switch,
add .03 lb. for each additional deck.
1 All max. number of positions will be continuous
rotation (no stops). All others will have stops.
P/N CODE:
HOW TO ORDER
*ADD FOR DECK IDENTIFICATION 4
*ADD FOR PANEL SEAL
*ADD FOR SHAFT SEAL
NO. OF POSITIONS 1 2
NO. OF DECKS (9 MAX.)
3
EC 15 A 1-24 S P D
*These options may be omitted or added
to the basic part number and will not
affect the reading of the code.
SWITCH CODE (A or B)
DEGREE OF INDEX (15, 18, 22.5, 30, 36 or 45)
SWITCH SERIES
If unable to use standard code, contact factory for UNIQUE PART NO.
3111 Winona Avenue
Burbank, California 91504
Phone: (818)846-1800
FAX: (818)842-3396
CODE A
TRUTH TABLE
STANDARD CODE
Common "C"
connected
to terminals
CODE B
TRUTH TABLE
BINARY CODE
DIAL POSITION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DIAL
Common "C"
connected
to terminals
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
POSITION 16 8 4 2 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NOTE: For switches with fewer than 24 positions, only the portion ot the
truth table corresponding to the specified number of positions shall apply.
About the problem of specifying register group in C51 interrupt program
In the interrupt program of C51, you can use using to specify the register group to make the interrupt program faster. Using 1 The interrupt program uses register group 1. The default register group u...
eaglet_121 Embedded System
Newbie, looking for advice
I want to learn Zigbee recently, but it's hard to find information. Can anyone give me some practical information, preferably from entry level to mastery? If you have any, please send it to my email [...
caoqing577 RF/Wirelessly
When calling testbench, a problem occurs: Top-level design entity is undefined?
I have set the top-level file , and the project name and the top-level file name are actually the same, but why is it still not working, even for the mini- programs ? Please help me , I remember that ...
eeleader-mcu FPGA/CPLD
Infrared tube program problem
[i=s] This post was last edited by gh131413 on 2016-1-3 22:37 [/i] Recently, I suddenly thought of the single-chip program control of infrared tubes. I have never thought about it or done it before, s...
gh131413 MCU
Internet of Things Discussion
From EEWORLD cooperation group 49900581 Group owner: wangkj I now want to promote this thing as open source. After you run the server, you can connect the hardware to this server. I can give you the s...
sinanjj Embedded System
Wince touch screen calibration problem
Recently, when debugging the touch screen, I found that when running the calibration program, the system always crashes and pops up messages such as raise exception... device.exe or (gwes.exe) and the...
guoqingling988 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 890  501  190  701  1766  18  11  4  15  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号