FDM09/15SPG1SR-K1019

Description
D Subminiature Connector, 15 Contact(s), Female-Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size309KB,8 Pages
ManufacturerMolex
Websitehttps://www.molex.com/molex/home
Environmental Compliance
Download Datasheet Parametric View All

FDM09/15SPG1SR-K1019 Overview

D Subminiature Connector, 15 Contact(s), Female-Male, Solder Terminal, ROHS COMPLIANT

FDM09/15SPG1SR-K1019 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARD: DIN 41652, OTHER STACKING CONNECTOR: 9 CONTACTS, SHELL SIZE: 1/E
Connector typeD SUBMINIATURE CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE-MALE
Contact materialCOPPER ALLOY
DIN complianceYES
empty shellNO
Filter functionNO
IEC complianceNO
insulator materialGLASS FILLED POLYESTER
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeBOARD
OptionsGENERAL PURPOSE
Shell surfaceTIN
Shell materialSTEEL
Housing size2/A
Termination typeSOLDER
Total number of contacts15
UL Flammability Code94V-0
Base Number Matches1
Dualport Connectors
Dualport Steckverbinder
Dualport Connectors
Product Description
Produktbeschreibung
Dualport Steckverbinder
Advantages and Special Features
I
Compact connector with dual assembly („Dualport“)
I
Multiple assembly combinations with various
layouts available
I
Available in sizes 9-way to 7-way
I
I
I
I
I
Pin and socket contacts, right angled
Stamped contacts
Various installation heights available
Also available as a mixed layout version
Multiple component parts, accessories and modifications
available (eg. contact protection cap)
Vorteile und Merkmale im Überblick
I
Kompakter Steckverbinder mit zweifachem
Aufbau („Dualport“)
I
Verschiedene Aufbaukombinationen mit unterschiedlichen
Layouts möglich
I
Polzahlen 9 bis 37 verfügbar
I
Pin-/Buchsenkontakte, abgewinkelt
I
Gestanzte Kontakte
I
Unterschiedliche Einbauhöhen erhältlich
I
Layout auch als Mischpolleiste verfügbar
I
Vielfältige Anbauteile, Zubehör und Modifikationen
erhältlich (z.B. Kontaktschutzkappe)
Dimensions FD...L, FD...M, FD...S
Abmessungen FD...L, FD...M, FD...S
Also available with mounted contact
cover under the modification number
...-K1019.
Auch mit montierter Kontaktschutzkappe
als Modifikationsnummer ...-K1019
lieferbar.
Inner thread 4-40 UNC, M3 or
hexagon nut 4-40 UNC, M3 or
through hole Ø 3.1mm (Ø 0.122”)
Innengewinde 4-40 UNC, M3 oder
Sechskantbolzen 4-40 UNC, M3 oder
Durchgangsloch Ø 3,1mm
Number of Contacts
Polzahlen
A
B
C
Mounting Height
/
Einbauhöhe
Small /
Klein
For /
für
7 TE*
Medium /
Mittel
For /
für
7 TE*
19,05
(0.750)
19,05
(0.750)
19,05
(0.750)
19,05
(0.750)
Large /
Groß
For /
für
8 TE*
22,86
(0.900)
22,86
(0.900)
22,86
(0.900)
22,86
(0.900)
D
Mounting Height /
Einbauhöhe
Small /
Klein
For /
für
7 TE*
28,48
(1.121)
28,48
(1.121)
28,48
(1.121)
28,48
(1.121)
Medium /
Mittel
For /
für
7 TE*
31,65
(1.246)
31,65
(1.246)
31,65
(1.246)
31,65
(1.246)
Large /
Groß
For /
für
8 TE*
35,46
(1.396)
35,46
(1.396)
35,46
(1.396)
35,46
(1.396)
30,8
2*9
(1.213)
39,1
2 * 15
(1.539)
53,0
2 * 25
(2.087)
69,3
2 * 37
(2.728)
25,0
(0.984)
33,3
(1.311)
47,04
(1.852)
63,5
(2.500)
15,88
(0.625)
15,88
(0.625)
15,88
(0.625)
15,88
(0.625)
Dimensions in mm (inch) -
Abmessungen in mm (inch)
* TE = Division unit, please see bottom of page 72.
* TE = Teilungseinheit, siehe Seite 72 unten.
 I connecting is our business
【TI Classic】Less is not necessarily better
[align=left]:)[font=宋体][size=14.0pt]Today, I recommend to you the experience summary of TI senior application engineer Upal Sengupta, "Less is not necessarily better". Under the guidance of the view t...
德州仪器 Analogue and Mixed Signal
【LuatOS-ESP32】Development environment construction
[Preface] I have been on business trips a lot recently, and tomorrow will be another week. I started something, but I can’t keep up for a while. Today I will share with you the environment I have set ...
lugl4313820 Domestic Chip Exchange
Proteus simulation 430 prompts error
When using proteus to simulate 430, all settings are correct, but when running, proteus prompts that the chip selection is wrong [img] data: image/png; base64,iVBORw0KGgoAAAANSUhEUgAABBQAAAA9CAIAAACSk...
sinianhuan Microcontroller MCU
I am learning DSP, but I find that DSP is not very useful! I have no future~~
I found that DSP is not very useful and the price is high. For audio and video encoding and decoding, it is cheaper to use a dedicated ASC circuit with higher performance. The manufacturers of this so...
netjob DSP and ARM Processors
Why do I get garbled code when I compile two timer interrupts after merging them? ? Separate compilation is normal. Help!
#include #includesbit p10=P1^0; //digital tube control end sbit p11=P1^1; sbit p12=P1^2; sbit p13=P1^3; sbit p20=P2^0; //button control end sbit p21=P2^1; sbit p22=P2^2; sbit p27=P2^7; bit GoFlag; #de...
liengzin8 51mcu
Easy-to-use Verilog serial UART program
==========================================================================//-----------------------------------------------------// Design Name : uart // File Name : uart.v//: Simple UART// Coder : De...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 492  824  1  1316  1195  10  17  1  27  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号